10 resultados para ON-LINE ANALYTICAL PROCESSING (OLAP)
em Universidad de Alicante
Resumo:
This paper analyzes the learning experiences and opinions obtained from a group of undergraduate students in their interaction with several on-line multimedia resources included in a free on-line course about Computer Networks. These new educational resources employed are based on the Web2.0 approach such as blogs, videos and virtual labs which have been added in a web-site for distance self-learning.
Resumo:
A microwave-based thermal nebulizer (MWTN) has been employed for the first time as on-line preconcentration device in inductively coupled plasma atomic emission spectrometry (ICP-AES). By the appropriate selection of the experimental conditions, the MWTN could be either operated as a conventional thermal nebulizer or as on-line analyte preconcentration and nebulization device. Thus, when operating at microwave power values above 100 W and highly concentrated alcohol solutions, the amount of energy per solvent mass liquid unit (EMR) is high enough to completely evaporate the solvent inside the system and, as a consequence, the analyte is deposited (and then preconcentrated) on the inner walls of the MWTN capillary. When reducing the EMR to the appropriate value (e.g., by reducing the microwave power at a constant sample uptake rate) the retained analyte is swept along by the liquid-gas stream and an analyte-enriched aerosol is generated and next introduced into the plasma cell. Emission signals obtained with the MWTN operating in preconcentration-nebulization mode improved when increasing preconcentration time and sample uptake rate as well as when decreasing the nozzle inner diameter. When running with pure ethanol solution at its optimum experimental conditions, the MWTN in preconcentration-nebulization mode afforded limits of detection up to one order of magnitude lowers than those obtained operating the MWTN exclusively as a nebulizer. To validate the method, the multi-element analysis (i.e. Al, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Pb and Zn) of different commercial spirit samples in ICP-AES has been performed. Analyte recoveries for all the elements studied ranged between 93% and 107% and the dynamic linear range covered up to 4 orders of magnitude (i.e. from 0.1 to 1000 μg L−1). In these analysis, both MWTN operating modes afforded similar results. Nevertheless, the preconcentration-nebulization mode permits to determine a higher number of analytes due to its higher detection capabilities.
Resumo:
En la asignatura Sistemas Inteligentes del grado en Ingeniería Informática, durante el curso 2013-14, se planteó a los estudiantes un sistema de evaluación continua de la parte teórica consistente en la realización de controles on-line utilizando cuestionarios Moodle. En las normas de evaluación de la asignatura, los controles acumulaban toda la materia impartida hasta la fecha y su peso creciente de cara a la obtención de la nota final. Teníamos especial interés en determinar si el sistema resultaba estimulante para los estudiantes. El artículo aborda la evaluación continua, el contexto de la asignatura y los criterios de evaluación que se establecieron para la evaluación de la parte teórica de la asignatura. Además, se presentan las características de los cuestionarios Moodle, se aporta la encuesta de valoración del método que se pasó a los estudiantes, los resultados obtenidos en la citada encuesta, las conclusiones y las recomendaciones para el futuro. Deseamos destacar el soporte de la “Red de Investigación en Sistemas Inteligentes. Evaluación continua mediante controles utilizando Moodle” Código de Red ICE: 3021.
Resumo:
La implementación de las nuevas tecnologías o TIC’s en el sector turístico se ha visto favorecida, en los últimos años, por las posibilidades que Internet ofrece de poder comprobar instantáneamente la existencia real del proveedor del servicio, la veracidad del servicio prestado o las condiciones en que se presta.. El aumento de la contratación electrónica de servicios turísticos exige que los proveedores de estos servicios y los turistas tengan en cuenta las diferentes normas jurídicas que resultan de aplicación en el ámbito de los servicios de la sociedad de la información, principalmente, la Ley 34/2002, de 11 de julio, de Servicios de la Sociedad de la Información y de Comercio Electrónico (LSSI), las normas reguladoras del consumo, en concreto, el Real Decreto legislativo 1/2007, de 16 de noviembre, por el que se aprueba el texto refundido de la Ley General para la Defensa de los Consumidores y Usuarios y otras leyes complementarias (TRLGDCU) y su modificación por la Ley 3/2014, de 27 de marzo, así como las diferentes normas autonómicas reguladoras del turismo que existen en la actualidad. En definitiva, un estudio detallado de las implicaciones que la contratación electrónica de servicios turísticos supone realizar una descripción legal del régimen jurídico que resulta de aplicación a los diferentes oferentes e intermediarios que intervienen esta nueva modalidad contractual y a los denominados paquetes dinámicos de turismo.
Resumo:
La red tenía por objeto llevar a cabo un especial seguimiento del grupo on line del Grado en Criminología que se imparte en la titulación y para el que son necesarios esfuerzos de coordinación adicionales y métodos docentes específicos a la docencia no presencial. Así, la red ha constituido un espacio de reflexión sobre docencia no presencial, que ha dado como resultado la adopción e implementación de acciones de mejora.
Resumo:
Integrity assurance of configuration data has a significant impact on microcontroller-based systems reliability. This is especially true when running applications driven by events which behavior is tightly coupled to this kind of data. This work proposes a new hybrid technique that combines hardware and software resources for detecting and recovering soft-errors in system configuration data. Our approach is based on the utilization of a common built-in microcontroller resource (timer) that works jointly with a software-based technique, which is responsible to periodically refresh the configuration data. The experiments demonstrate that non-destructive single event effects can be effectively mitigated with reduced overheads. Results show an important increase in fault coverage for SEUs and SETs, about one order of magnitude.
Resumo:
A description is given of the structure of, theoretical background of, and experiences gained from, a course in legal English-Spanish translation taught at the University of Alicante.
Resumo:
The majority of the organizations store their historical business information in data warehouses which are queried to make strategic decisions by using online analytical processing (OLAP) tools. This information has to be correctly assured against unauthorized accesses, but nevertheless there are a great amount of legacy OLAP applications that have been developed without considering security aspects or these have been incorporated once the system was implemented. This work defines a reverse engineering process that allows us to obtain the conceptual model corresponding to a legacy OLAP application, and also analyses and represents the security aspects that could have established. This process has been aligned with a model-driven architecture for developing secure OLAP applications by defining the transformations needed to automatically apply it. Once the conceptual model has been extracted, it can be easily modified and improved with security, and automatically transformed to generate the new implementation.
Resumo:
A range of catalysts based on Pd nanoparticles supported on inorganic supports such as BETA and ZSM-5 zeolites, a silicoaluminophosphate molecular sieve (SAPO-5) and γ-alumina as a standard support have been tested for the total oxidation of naphthalene (100 ppm, total flow 50 ml/min) showing a conversion to carbon dioxide of 100% between 165 and 180 °C for all the analysed catalysts. From the combined use of zeolites with PVP polymer protected Pd based nanoparticles, enhanced properties have been found for the total abatement of naphthalene in contrast with other kinds of catalysts. A Pd/BETA catalyst has been demonstrated to have excellent activity, with a high degree of stability, as shown by time on line experiments maintaining 100% conversion to CO2 during the 48 h tested.
Resumo:
Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) has been employed to carry out the determination of both major anions and cations in water samples. The anion quantification has been performed by means of a new automatic accessory. In this device chloride has been determined by continuously adding a silver nitrate solution. As a result solid silver chloride particles are formed and retained on a nylon filter inserted in the line. The emission intensity is read at a silver characteristic wavelength. By plotting the drop in silver signal versus the chloride concentration, a straight line is obtained. As regards bicarbonate, this anion has been on-line transformed into carbon dioxide with the help of a 2.0 mol L−1 nitric acid stream. Carbon signal is linearly related with bicarbonate concentration. Finally, information about sulfate concentration has been achieved by means of the measurement of sulfur emission intensity. All the steps have been simultaneously and automatically performed. With this setup detection limits have been 1.0, 0.4 and 0.09 mg L−1 for chloride, bicarbonate and sulfate, respectively. Furthermore, it affords good precision with RSD below 6 %. Cation (Ca, Mg, Na and K) concentration, in turn, has been obtained by simultaneously reading the emission intensity at characteristic wavelengths. The obtained limits of detection have been 8 × 10−3, 2 × 10−3, 8 × 10−4 and 10−2 mg L−1 for sodium, potassium, magnesium and calcium, respectively. As regards sample throughput, about 30 samples h−1 can be analysed. Validation results have revealed that the obtained concentrations for these anions are not significantly different as compared to the data provided by conventional methods. Finally, by considering the data for anions and cations, precise ion balances have been obtained for well and mineral water samples.