12 resultados para Error of measurement

em Universidad de Alicante


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El Instituto Nacional de Estadística ha decidido elaborar una nueva Estadística de Migraciones utilizando como base la Estadística de Variaciones Residenciales. En este artículo se aportan algunos argumentos que apoyan esta decisión, ante la persistente falta de coherencia entre las fuentes del sistema estadístico español para captar la movilidad. En particular, se profundiza en los problemas de subestimación e inconsistencia interna de la Encuesta de Población Activa para medir la inmigración, a la vista de las diferencias entre las tres series de flujos de inmigración internacional que es posible estimar a partir de la misma.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A reduced set of measurement geometries allows the spectral reflectance of special effect coatings to be predicted for any other geometry. A physical model based on flake-related parameters has been used to determine nonredundant measurement geometries for the complete description of the spectral bidirectional reflectance distribution function (BRDF). The analysis of experimental spectral BRDF was carried out by means of principal component analysis. From this analysis, a set of nine measurement geometries was proposed to characterize special effect coatings. It was shown that, for two different special effect coatings, these geometries provide a good prediction of their complete color shift.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Subsidence is a natural hazard that affects wide areas in the world causing important economic costs annually. This phenomenon has occurred in the metropolitan area of Murcia City (SE Spain) as a result of groundwater overexploitation. In this work aquifer system subsidence is investigated using an advanced differential SAR interferometry remote sensing technique (A-DInSAR) called Stable Point Network (SPN). The SPN derived displacement results, mainly the velocity displacement maps and the time series of the displacement, reveal that in the period 2004–2008 the rate of subsidence in Murcia metropolitan area doubled with respect to the previous period from 1995 to 2005. The acceleration of the deformation phenomenon is explained by the drought period started in 2006. The comparison of the temporal evolution of the displacements measured with the extensometers and the SPN technique shows an average absolute error of 3.9±3.8 mm. Finally, results from a finite element model developed to simulate the recorded time history subsidence from known water table height changes compares well with the SPN displacement time series estimations. This result demonstrates the potential of A-DInSAR techniques to validate subsidence prediction models as an alternative to using instrumental ground based techniques for validation.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The Growing Neural Gas model is used widely in artificial neural networks. However, its application is limited in some contexts by the proliferation of nodes in dense areas of the input space. In this study, we introduce some modifications to address this problem by imposing three restrictions on the insertion of new nodes. Each restriction aims to maintain the homogeneous values of selected criteria. One criterion is related to the square error of classification and an alternative approach is proposed for avoiding additional computational costs. Three parameters are added that allow the regulation of the restriction criteria. The resulting algorithm allows models to be obtained that suit specific needs by specifying meaningful parameters.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: The aim of this study is to determine the reliability of corneal thickness measurements derived from SOCT Copernicus HR (Fourier domain OCT). Methods: Thirty healthy eyes of 30 subjects were evaluated. One eye of each patient was chosen randomly. Images were obtained of the central (up to 2.0 mm from the corneal apex) and paracentral (2.0 to 4.0 mm) cornea. We assessed corneal thickness (central and paracentral) and epithelium thickness. The intra-observer repeatability data were analysed using the intra-class correlation coefficient (ICC) for a range of 95 per cent within-subject standard deviation (SW) and the within-subject coefficient of variation (CW). The level of agreement by Bland–Altman analysis was also represented for the study of the reproducibility between observers and agreement between methods of measurement (automatic versus manual). Results: The mean value of the central corneal thickness (CCT) was 542.4 ± 30.1 μm (SD). There was a high intra-observer agreement, finding the best result in the central sector with an intra-class correlation coefficient of 0.99, 95 per cent CI (0.989 to 0.997) and the worst, in the minimum corneal thickness, with an intra-class correlation coefficient of 0.672, 95 per cent CI (0.417 to 0.829). Reproducibility between observers was very high. The best result was found in the central sector thickness obtained both manually and automatically with an intra-class correlation coefficient of 0.990 in both cases and the worst result in the maximum corneal thickness with an intra-class correlation coefficient of 0.827. The agreement between measurement methods was also very high with intra-class correlation coefficient greater than 0.91. On the other hand the repeatability and reproducibility for epithelial measurements was poor. Conclusion: Pachymetric mapping with SOCT Copernicus HR was found to be highly repeatable and reproducible. We found that the device lacks an appropriate ergonomic design as proper focusing of the laser beam onto the cornea for anterior segment scanning required that patients were positioned slightly farther away from the machine head-rest than in the setup for retinal imaging.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The continuous improvement of management and assessment processes for curricular external internships has led a group of university teachers specialised in this area to develop a mixed model of measurement that combines the verification of skill acquisition by those students choosing external internships with the satisfaction of the parties involved in that process. They included academics, educational tutors of companies and organisations and administration and services personnel in the latter category. The experience, developed within University of Alicante, has been carried out in the degrees of Business Administration and Management, Business Studies, Economics, Advertising and Public Relations, Sociology and Social Work, all part of the Faculty of Economics and Business. By designing and managing closed standardised interviews and other research tools, validated outside the centre, a system of continuous improvement and quality assurance has been created, clearly contributing to the gradual increase in the number of students with internships in this Faculty, as well as to the improvement in satisfaction, efficiency and efficacy indicators at a global level. As this experience of educational innovation has shown, the acquisition of curricular knowledge, skills, abilities and competences by the students is directly correlated with the satisfaction of those parties involved in a process that takes the student beyond the physical borders of a university campus. Ensuring the latter is a task made easier by the implementation of a mixed assessment method, combining continuous and final assessment, and characterised by its rigorousness and simple management. This report presents that model, subject in turn to a persistent and continuous control, a model all parties involved in the external internships are taking part of. Its short-term results imply an increase, estimated at 15% for the last course, in the number of students choosing curricular internships and, for the medium and long-term, a major interweaving between the academic world and its social and productive environment, both in the business and institutional areas. The potentiality of this assessment model does not lie only in the quality of its measurement tools, but also in the effects from its use in the various groups and in the actions that are carried out as a result of its implementation and which, without any doubt and as it is shown below, are the real guarantee of a continuous improvement.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Colors of special-effect coatings have strong dependence on illumination/viewing geometry and an appealing appearance. An open question is to ask about the minimum number of measurement geometries required to completely characterize their observed color shift. A recently published principal components analysis (PCA)-based procedure to estimate the color of special-effect coatings at any geometry from measurements at a reduced set of geometries was tested in this work by using the measurement geometries of commercial portable multiangle spectrophotometers X-Rite MA98, Datacolor FX10, and BYK-mac as reduced sets. The performance of the proposed PCA procedure for the color-shift estimation for these commercial geometries has been examined for 15 special-effect coatings. Our results suggest that for rendering the color appearance of 3D objects covered with special-effect coatings, the color accuracy obtained with this procedure may be sufficient. This is the case especially if geometries of X-Rite MA98 or Datacolor FX10 are used.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of foundation embedment on settlement calculation is a widely researched topic in which there is no scientific consensus regarding the magnitude of settlement reduction. In this paper, a non-linear three dimensional Finite Element analysis has been performed with the aim of evaluating the aforementioned effect. For this purpose, 1800 models were run considering different variables, such as the depth and dimensions of the foundation and the Young’s modulus and Poisson’s ratio of the soil. The settlements from models with foundations at surface level and at depth were then compared and the relationship between them established. The statistical analysis of this data allowed two new expressions, with a mean maximum error of 1.80%, for the embedment influence factor of a foundation to be proposed and these to be compared with commonly used corrections. The proposed equations were validated by comparing the settlements calculated with the proposed influence factors and the true settlements measured in several real foundations. From the comprehensive study of all modelled cases, an improved approach, when compared to those proposed by other authors, for the calculation of the true elastic settlements of an embedded foundation is proposed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Concepts: %WL: Percentage of weight loss; %FL: Percentage of fat loss. Objective: evaluate which unit of measurement for weight loss could determine the success or failure of dietary treatment for overweight and obesity. Method: 4,625 consultations carried out on 616 patients in the southeast of Spain from 2006 to 2012. All of the patients were over 25 years of age and suffered from overweight or obesity. The consultations were carried out every fortnight, using the Mediterranean or low-calorie diet. The patients were divided into four groups according to their %WL and %FL. Results: most of the sample consisted of: women; participants between 25-45 years of age; attended consultations for over a month and a half; obese. 80% of the patients obtained a %FL ≥ 5% (15.5 ± 12.8). The groups with a higher %FL obtained significant differences in weight loss (22.6 vs 11.2%, p = 0.000). The multinomial analysis shows significant differences between the groups with the highest %FL and the lowest %WL and %FL: sex (p = 0.006 vs p = 0.005), BMI (p = 0.010 vs p = 0.003) and attendance (p = 0.000 vs p = 0.000). Conclusion: the patients who lost < 5% of fat had higher initial parameters (percentage of weight and fat); most of the sample lost ≥ 5% of fat. This means that the method of personalised dietary treatment results in a high fat loss; fat is an indicator of the quality loss obtained. Recommendations: use the measurement of fat as a complementary unit of measurement to weight loss; establish a limit of 5% to evaluate such loss; and increase this type of research in any method of weight loss.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A twenty-year period of severe land subsidence evolution in the Alto Guadalentín Basin (southeast Spain) is monitored using multi-sensor SAR images, processed by advanced differential interferometric synthetic aperture radar (DInSAR) techniques. The SAR images used in this study consist of four datasets acquired by ERS-1/2, ENVISAT, ALOS and COSMO-SkyMed satellites between 1992 and 2012. The integration of ground surface displacement maps retrieved for different time periods allows us to quantify up to 2.50 m of cumulated displacements that occurred between 1992 and 2012 in the Alto Guadalentín Basin. DInSAR results were locally compared with global positioning system (GPS) data available for two continuous stations located in the study area, demonstrating the high consistency of local vertical motion measurements between the two different surveying techniques. An average absolute error of 4.6 ± 4 mm for the ALOS data and of 4.8 ± 3.5 mm for the COSMO-SkyMed data confirmed the reliability of the analysis. The spatial analysis of DInSAR ground surface displacement reveals a direct correlation with the thickness of the compressible alluvial deposits. Detected ground subsidence in the past 20 years is most likely a consequence of a 100–200 m groundwater level drop that has persisted since the 1970s due to the overexploitation of the Alto Guadalentín aquifer system. The negative gradient of the pore pressure is responsible for the extremely slow consolidation of a very thick (> 100 m) layer of fine-grained silt and clay layers with low vertical hydraulic permeability (approximately 50 mm/h) wherein the maximum settlement has still not been reached.