6 resultados para Argentine screen

em Universidad de Alicante


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article aims to undertake a preliminary comparative review of the concepts of political representation developed by the Spanish and Argentinean liberalism during the construction of the parliamentary and constitutional regimes in the nineteenth century. The idea of the representative government, as a regulatory mechanism of political participation, is considered in terms of an analysis of the right to vote, of the processes to develop citizenship, and of political modernization. Legislation on the right to vote, born as the political right par excellence during the nineteenth century, gives an excellent guide to these political processes of major scope and depth that characterize the contemporary world. The comparison between the Spanish and Argentinean cases shows that exchanges, transfers of legislative models and cultural movements took place in the birth of the concept of political representation in both countries. This enables us to identify the differences of in each case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach is presented, whereby gold nanostructured screen-printed carbon electrodes (SPCnAuEs) are combined with in-situ ionic liquid formation dispersive liquid–liquid microextraction (in-situ IL-DLLME) and microvolume back-extraction for the determination of mercury in water samples. In-situ IL-DLLME is based on a simple metathesis reaction between a water-miscible IL and a salt to form a water-immiscible IL into sample solution. Mercury complex with ammonium pyrrolidinedithiocarbamate is extracted from sample solution into the water-immiscible IL formed in-situ. Then, an ultrasound-assisted procedure is employed to back-extract the mercury into 10 µL of a 4 M HCl aqueous solution, which is finally analyzed using SPCnAuEs. Sample preparation methodology was optimized using a multivariate optimization strategy. Under optimized conditions, a linear range between 0.5 and 10 µg L−1 was obtained with a correlation coefficient of 0.997 for six calibration points. The limit of detection obtained was 0.2 µg L−1, which is lower than the threshold value established by the Environmental Protection Agency and European Union (i.e., 2 µg L−1 and 1 µg L−1, respectively). The repeatability of the proposed method was evaluated at two different spiking levels (3 and 10 µg L−1) and a coefficient of variation of 13% was obtained in both cases. The performance of the proposed methodology was evaluated in real-world water samples including tap water, bottled water, river water and industrial wastewater. Relative recoveries between 95% and 108% were obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Today's generation of Internet devices has changed how users are interacting with media, from passive and unidirectional users to proactive and interactive. Users can use these devices to comment or rate a TV show and search for related information regarding characters, facts or personalities. This phenomenon is known as second screen. This paper describes SAM, an EU-funded research project that focuses on developing an advanced digital media delivery platform based on second screen interaction and content syndication within a social media context, providing open and standardised ways of characterising, discovering and syndicating digital assets. This work provides an overview of the project and its main objectives, focusing on the NLP challenges to be faced and the technologies developed so far.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Social networking apps, sites and technologies offer a wide range of opportunities for businesses and developers to exploit the vast amount of information and user-generated content produced through social networking. In addition, the notion of second screen TV usage appears more influential than ever, with viewers continuously seeking further information and deeper engagement while watching their favourite movies or TV shows. In this work, the authors present SAM, an innovative platform that combines social media, content syndication and targets second screen usage to enhance media content provisioning, renovate the interaction with end-users and enrich their experience. SAM incorporates modern technologies and novel features in the areas of content management, dynamic social media, social mining, semantic annotation and multi-device representation to facilitate an advanced business environment for broadcasters, content and metadata providers, and editors to better exploit their assets and increase their revenues.