10 resultados para bile duct bypass

em University of Queensland eSpace - Australia


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: To compare cell phenotypes displayed by cholangiocarcinomas and adjacent bile duct lesions in patients from an area endemic in liver-fluke infestation and those with sporadic cholangiocarcinoma. Methods: 65 fluke-associated and 47 sporadic cholangiocarcinomas and 6 normal livers were studied. Serial paraffin-wax sections were stained immunohistochemically with monoclonal antibodies characterising a Brunner or pyloric gland metaplasia cell phenotype (antigens D10 and 1F6), intestinal goblet cells (antigen 17NM), gastric foveolar apomucin (MUC5AC), a gastrointestinal epithelium cytokeratin (CK20) and the p53 protein. Results: 60% of the 112 cholangiocarcinomas expressed antigen D10, 68% MUC5AC, 33% antigen 17NM and 20% CK20; 37% showed overexpression of p53. When present together in a cholangiocarcinoma, cancer cells expressing D10 were distinct from those displaying 17NM or MUC5AC. Many more fluke-associated cholangiocarcinomas than sporadic cholangiocarcinomas displayed 17NM and p53 expression. Most cases of hyperplastic and dysplastic biliary epithelium expressed D10 strongly. Pyloric gland metaplasia and peribiliary glands displayed D10 and 1F6, with peribiliary gland hyperplasia more evident in the livers with fluke-associated cholangiocarcinoma; goblet cells in intestinal metaplasia stained for 17NM. No notable association of expression between any two antigens (including p53) was found in the cancers. Conclusions: Most cases of dysplastic biliary epithelium and cholangiocarcinoma display a Brunner or pyloric gland cell phenotype and a gastric foveolar cell phenotype. The expression of D10 in hyperplastic and dysplastic epithelium and in cholangiocarcinoma is consistent with a dysplasia-carcinoma sequence. Many more fluke-associated cholangiocarcinomas than sporadic cholangiocarcinoma display an intestinal goblet cell phenotype and overexpress p53, indicating differences in the aetiopathology of the cancers in the two groups of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research suggests that the retrospective review of the International Classification of Disease (ICD-9-CM) codes assigned to a patient episode will identify a similar number of healthcare-acquired surgical-site infections as compared with prospective surveillance by infection control practitioners (ICP). We tested this finding by replicating the methods for 380 surgical procedures. The sensitivity and specificity of the ICP undertaking prospective surveillance was 80% and 100%, and the sensitivity and specificity of the review of ICD-10-AM codes was 60% and 98.9%. Based on these results we do not support retrospective review of ICD-10-AM codes in preference prospective surveillance for SSI. (C) 2004 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the introduction of synthetic vascular grafts in the 1960s, only two-stage endothelial cell seeding has demonstrated any significant improvement over conventional vascular grafts, and its benefits have yet to be demonstrated on a large scale. Tissue engineering is a rapidly expanding field with great potential, but efforts to construct tissue-engineered arterial grafts have, to date, yielded little clinical success. This review explores the latest approaches to the construction of a superior vascular graft, along with its potential for use in the clinic in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Health-related quality of life (HRQOL) among long-term survivors of coronary artery bypass surgery is an important outcome that has been little studied at the population level. Methods A postal survey was conducted in 1999 to 2000 in patients 6 to 20 years after coronary artery bypass graft (CABG) surgery in Western-Australia. A random stratified sample of 2500 was drawn from 8910 patients who had their first CABG surgery in 1980 to 1993. Health-related quality of life was measured with Short Form 36 and EuroQol visual analogue scale. Results Response was 82% (n = 2061). Health-related quality of life declined with age and was similar for men and women, although scores for women were worse for physical functioning. Compared with Australian population norms, the age- and sex-standardized scores of survivors of CABG were generally worse, mainly in the physical domain. Reported angina at the time of follow-up (33%), symptoms of heart failure equivalent to New York Heart Association (NYHA) classes II to IV (34%), and comorbidities such as diabetes and hypertension were associated with poorer HRQOL. For both men and women without angina or heart failure at follow-up, HRQOL was no different from that of the general population. Conclusion Overall, the quality of life among long-term survivors of CABG is worse than that of the general population, the difference being mainly attributable to recurrent symptoms and comorbidities. Quality of life for those without angina or heart failure at follow-up was equivalent to the population norms, providing an incentive to maximize efforts to abolish angina and ameliorate heart failure symptoms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Postoperative cognitive dysfunction (POCD) after coronary artery bypass graft surgery is a common complication for which, despite many clinical investigations, no definitive etiology has been found. The current use of both high and low-dose fentanyl as anesthetic techniques allowed us to investigate the effect of fentanyl on the incidence of POCD. Methods. Three hundred fifty patients scheduled to undergo elective coronary artery bypass graft surgery were randomized to receive either high-dose fentanyl (50 mu g/kg) or low-dose fentanyl (10 mu g/kg) as the basis of the anesthetic. All patients underwent neuropsychological testing before surgery and at 1 week, 3 months, and 12 months after surgery. Results. One hundred sixty-eight patients in the low-dose group and 158 patients in the high-dose group were included in the final analysis. Neuropsychological testing was performed on 88%, 93%, and 92% of patients at 1 week, 3 months, and 12 months, respectively. There was no difference between group mean scores at any of the three testing times. Analysis of individual patients by the 20% rule did not detect any differences between groups. The one SD rule, which has fewer false-positive results, detected significantly more patients with POCD in the low-dose group than in the high-dose group at 1 week (23.6% vs. 13.7%; P = 0.03) but not at the other testing times. Patients with POCD spent an average of 1.2 days longer in the hospital than those without POCD (P = 0.021). Conclusions: High-dose fentanyl is not associated with a difference in the incidence of POCD at 3 or 12 months after surgery. Low-dose fentanyl leads to shorter postoperative ventilation times and may be associated with a greater incidence of POCD 1 week after surgery. Early POCD is associated with an increased duration of stay in the hospital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents closed form solutions for fully developed temperature distribution and entropy generation due to forced convection in microelectromechanical systems (MEMS) in the Slip-flow regime, for which the Knudsen number lies within the range 0.001

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Grid connected PhotoVoltaic (PV) inverters fall into three broad categories — Central, String and Module Integrated Converers (MICs). MICs offer any avantaes in performance and flexibility, but are at a cost disadvantage. Two alternative novel approaches proposed by the author — cascaded dc-dc MICs and bypass dc-dc MICs — integrate a simple non-isolated intelligent dc-dc converter with each PV module to provide the advantages of dc-ac MICs at a lower cost. A suitable universal 150W 5A dc-dc converter design is presented based on two interleaved MOSFET half bridges. Testing shows Zero Voltage Switching (ZVS) keeps losses under 1W for bi-directional power flows up to 15W between two adjacent 12V PV modules for the bypass application, and efficiencies over 94% for most of the operational power range for the cascaded converter application. Based on the experimental results, potential optimizations to further reduce losses are discussed.