102 resultados para ECHO DOUBLE-RESONANCE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new approach for the design of genuinely finite-length shim and gradient coils, intended for use in magnetic resonance imaging equipment. A cylindrical target region is located asymmetrically, at an arbitrary position within a coil of finite length. A desired target field is specified on the surface of that region, and a method is given that enables winding patterns on the surface of the coil to be designed, to produce the desired field at the inner target region. The method uses a minimization technique combined with regularization, to find the current density on the surface of the coil. The method is illustrated for linear, quadratic and cubic magnetic target fields located asymmetrically within a finite-length coil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method is presented for the systematic design of asymmetric zonal shim coils for magnetic resonance applications. Fourier-series methods are used to represent the magnetic field inside and outside a circular cylinder of length 2L and radius a. The current density on the cylinder is also represented using Fourier series. Any desired field can be specified in advance on the cylinder's radius, over some nonsymmetric portion pL

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When patients undergo a magnetic resonance imaging scan, they are subject to both strong static and temporal magnetic fields. The temporal fields are designed to vary at each point in the region being imaged. This is achieved by the use of gradient coils. However, when the gradient coils are switched very rapidly, the strongly time-varying magnetic fields produced can be responsible for stimulating nerves in the peripheral regions of the body. This paper gives a somewhat novel explanation for this phenomenon. The physical mechanism suggested is supported by an illustrative theoretical calculation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

New designs for force-minimized compact high-field clinical MRI magnets are described. The design method is a modified simulated annealing (SA) procedure which includes Maxwell forces in the error function to be minimized. This permits an automated force reduction in the magnet designs while controlling the overall dimensions of the system. As SA optimization requires many iterations to achieve a final design, it is important that each iteration in the procedure is rapid. We have therefore developed a rapid force calculation algorithm. Novel designs for short 3- and 4-T clinical MRI systems are presented in which force reduction has been invoked. The final designs provide large homogeneous regions and reduced stray fields in remarkable short magnets. A shielded 4-T design that is approximately 30% shorter than current designs is presented. This novel magnet generates a full 50-cm diameter homogeneous region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Codeine is frequently added to paracetamol to treat post-operative dento-alveolar pain; studies have shown effectiveness in relief of post-operative pain at high doses but at the expense of central nervous and gastrointestinal side effects. There has been no trial to compare the efficacy and safety of paracetamol 1000mg with paracetamol 1000mg combined with codeine 30mg. Method. A randomized, single centre, double-blind prospective parallel group trial was performed to compare paracetamol 1000mg with paracetamol 1000mg with codeine 30mg for the relief of pain following surgical removal of impacted third molars, and analysed on an intention-to-treat (ITT) basis. Eighty-two patients were assigned randomly to receive either drug for a maximum of three doses. Patients recorded their pain intensity one hour after surgery and hourly thereafter for 12 hours. Results: The average increase in pain intensity over 12 hours was significantly less in patients receiving paracetamol plus codeine than in those receiving paracetamol alone (p=0.03) -1.81cm/h compared with 0.45cm/h - a difference of 1.13cm/h (95 per cent Cl: 0.18 to 2.08). Of the patients who received the paracetamol codeine combination, 62 per cent used escape medication compared with 75 per cent of those on paracetamol alone (p=0.20). There was no significant difference between the two groups in the proportion of patients experiencing adverse events (P=0.5). Conclusion: A combination of 1000mg paracetamol and 30mg codeine was significantly more effective in controlling pain for 12 hours following third molar removal, with no significant difference of side effects during the 12 hour period studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Read-only-memory-based (ROM-based) quantum computation (QC) is an alternative to oracle-based QC. It has the advantages of being less magical, and being more suited to implementing space-efficient computation (i.e., computation using the minimum number of writable qubits). Here we consider a number of small (one- and two-qubit) quantum algorithms illustrating different aspects of ROM-based QC. They are: (a) a one-qubit algorithm to solve the Deutsch problem; (b) a one-qubit binary multiplication algorithm; (c) a two-qubit controlled binary multiplication algorithm; and (d) a two-qubit ROM-based version of the Deutsch-Jozsa algorithm. For each algorithm we present experimental verification using nuclear magnetic resonance ensemble QC. The average fidelities for the implementation were in the ranges 0.9-0.97 for the one-qubit algorithms, and 0.84-0.94 for the two-qubit algorithms. We conclude with a discussion of future prospects for ROM-based quantum computation. We propose a four-qubit algorithm, using Grover's iterate, for solving a miniature real-world problem relating to the lengths of paths in a network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the influence of a single-mode cavity on the Autler-Townes doublet that arises when a three-level atom is strongly driven by a laser field tuned to one of the atomic transitions and probed by a tunable, weak field coupled to the other transition. We assume that the cavity mode is coupled to the driven transition and the cavity and laser frequencies are equal to the atomic transition frequency. We find that the Autler-Townes spectrum can have one, two or three peaks depending on the relative magnitudes of the Rabi frequencies of the cavity and driving fields. We show that, in order to understand the three-peaked spectrum, it is necessary to go beyond the secular approximation, leading to interesting quantum interference effects. We find that the positions and relative intensities of the three spectral components are affected strongly by the atom-cavity coupling strength g and the cavity damping K. For an increasing g and/or decreasing K the triplet evolves into a single peak. This results in 'undressing' of the system such that the atom collapses into its ground state. We interpret the spectral features in terms of the semiclassical dressed-atom model, and also provide complementary views of the cavity effects in terms of quantum Langevin equations and the fully quantized, 'double -dressing' model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Articulatory patterns and nasal resonance were assessed before and 6 months after orthognathic reconstruction surgery in five patients with dentofacial deformities. Perceptual and physiological assessments showed disorders of nasality and articulatory function preoperatively, two patients being hyponasal, and one hypernasal. Four patients had mild articulatory deficits, and four had reduced maximal lip or tongue pressures. Operation resulted in different patterns of change. Nasality deteriorated in three patients and articulatory precision and intelligibility improved in only one patient and showed no change in the other four. Operation improved interlabial pressures in three patients, while its impact on tongue pressures varied, being improved in one case, deteriorating in one, and remaining unchanged in the other three. The variability in the results highlights the need for routine assessment of speech and resonance before and after orthognathic reconstruction. (C) 2002 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with chronic liver disease (CLD) are catabolic and GH-resistant. The effects of supraphysiological recombinant human GH (rhGH; 0.2 IU.kg(-1).d(-1)) treatment in adults with CLD were assessed in a randomized, double-blind, placebo-controlled cross-over trial (4-wk dietary run-in, 4-wk treatment, and 2-wk wash-out phases). Nine adults with mild- to moderate-severity CLD participated (median age, 49 yr; three males and six females; Child's classification A in six and B in three). Biopsy-proven etiologies were: alcohol (four patients), primary biliary cirrhosis (three patients), non-A, non-B, non-C hepatitis (one patient), and cryptogenic (one patient). Treatment with rhGH increased serum IGF-I (median increase over placebo, +93 mug.liter(-1); P = 0.004), IGF-binding protein-3 (+0.9 mg.liter(-1): P = 0.004), and acid labile subunit (+10.7 nM; P = 0.004). Total body potassium (+8.0 g; P = 0.023), body weight (+1.6 kg; P = 0.008), and total body water (by bioelectrical impedance; +4.9 kg; P = 0.004) increased. Resting metabolic rate (+313 ml.kg(-1).min(-1); P = 0.004) and lipid oxidation (+1072.0 kcal.d(-1); P = 0.032) increased. Metabolic changes included increased fasting plasma glucose (+1.2 mm; P = 0.008), insulin (+33.8 mU.liter(-1); P = 0.004), C-peptide (+0.7 nM; P = 0.004), and free-fatty acids (+0.1 mEq.liter(-1); P = 0.04). Clinical side effects included worsening edema and ascites. Hepatocellular function did not change. Therefore, rbGH treatment in CLD: 1) overcame hepatic GH resistance; 2) may have improved whole-body protein catabolism; 3) increased lipolysis and lipid oxidation; 4) increased insulin resistance; and 5) had potent antinatriuretic effects. Long-term safety and efficacy require further assessment.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is an easily automated, reliable technique to investigate axial mixing within rotating drums. Moist bran can be clearly differentiated from dry bran using MRI allowing a non-segregating tracer for axial mixing. For a 20-cm diameter drum, the axial dispersion coefficient in the particle bed was 0.51 cm s(-2). Axial dispersion is scale-dependent.