54 resultados para Micron and small enterprise


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is an increasing demand to develop biosensor monitoring devices capable of biomarker profiling for predicting animal adulteration and detecting multiple chemical contaminants or toxins in food produce. Surface plasmon resonance (SPR) biosensors are label free detection systems that monitor the binding of specific biomolecular recognition elements with binding partners. Essential to this technology are the production of biochips where a selected binding partner, antibody, biomarker protein or low molecular weight contaminant, is immobilised. A micro-fluidic immobilisation device allowing the covalent attachment of up to 16 binding partners in a linear array on a single surface has been developed for compatibility with a prototype multiplex SPR analyser.

The immobilisation unit and multiplex SPR analyser were respectively evaluated in their ability to be fit-for-purpose for binding partner attachment and detection of high and low molecular weight molecules. The multiplexing capability of the dual technology was assessed using phycotoxin concentration analysis as a model system. The parent compounds of four toxin groups were immobilised within a single chip format and calibration curves were achieved. The chip design and SPR technology allowed the compartmentalisation of the binding interactions for each toxin group offering the added benefit of being able to distinguish between toxin families and perform concentration analysis. This model is particularly contemporary with the current drive to replace biological methods for phycotoxin screening.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High power femtosecond laser pulses have unique properties that could lead to their application as ionization or activation sources in mass spectrometry. By concentrating many photons into pulse lengths approaching the timescales associated with atomic motion, very strong electric field strengths are generated, which can efficiently ionize and fragment molecules without the need for resonant absorption. However, the complex interaction between these pulses and biomolecular species is not well understood. To address this issue, we have studied the interaction of intense, femtosecond pulses with a number of amino acids and small peptides. Unlike previous studies, we have used neutral forms of these molecular targets, which allowed us to investigate dissociation of radical cations without the spectra being complicated by the action of mobile protons. We found fragmentation was dominated by fast, radical-initiated dissociation close to the charge site generated by the initial ionization or from subsequent ultrafast migration of this charge. Fragments with lower yields, which are useful for structural determinations, were also observed and attributed to radical migration caused by hydrogen atom transfer within the molecule.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article proposes that a complementary relationship exists between the formalised nature of digital loyalty card data, and the informal nature of small business market orientation. A longitudinal, case-based research approach analysed this relationship in small firms given access to Tesco Clubcard data. The findings reveal a new-found structure and precision in small firm marketing planning from data exposure; this complemented rather than conflicted with an intuitive feel for markets. In addition, small firm owners were encouraged to include employees in marketing planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ambisonics and Higher Order Ambisonics (HOA) are scalable spatial audio techniques that attempt to present a sound scene to listeners over as large an area as possible. A localisation experiment was carried out to investigate the performance of a first and third order system at three listening positions - one in the centre and two off-centre - using a 5 m radius loudspeaker array. The results are briefly presented and compared to those of an earlier experiment on a 2.2 m loudspeaker array. In both experiments the off-centre listeners were placed such that the ratio of distance from the centre to the array radius was constant in both experiments. The test used a reverse target-pointer adjustment method to determine the error, both signed and absolute, for each combination of listening position and system. The results for both arrays were found to be very similar, suggesting that the relative amplitude of the loudspeakers, which were the same in both cases, was more dominant for localisation than the arrival time differences, which differed between array sizes.