Stress analysis of the cement fixation of orthopaedic implants to bone is frequently? carried out using finite element analysis. However, the stress distribution in the cement laver is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stein tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However; if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stein generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stein. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Reliable prediction of long-term medical device performance using computer simulation requires consideration of variability in surgical procedure, as well as patient-specific factors. However, even deterministic simulation of long-term failure processes for such devices is time and resource consuming so that including variability can lead to excessive time to achieve useful predictions. This study investigates the use of an accelerated probabilistic framework for predicting the likely performance envelope of a device and applies it to femoral prosthesis loosening in cemented hip arthroplasty.
A creep and fatigue damage failure model for bone cement, in conjunction with an interfacial fatigue model for the implant–cement interface, was used to simulate loosening of a prosthesis within a cement mantle. A deterministic set of trial simulations was used to account for variability of a set of surgical and patient factors, and a response surface method was used to perform and accelerate a Monte Carlo simulation to achieve an estimate of the likely range of prosthesis loosening. The proposed framework was used to conceptually investigate the influence of prosthesis selection and surgical placement on prosthesis migration.
Results demonstrate that the response surface method is capable of dramatically reducing the time to achieve convergence in mean and variance of predicted response variables. A critical requirement for realistic predictions is the size and quality of the initial training dataset used to generate the response surface and further work is required to determine the recommendations for a minimum number of initial trials. Results of this conceptual application predicted that loosening was sensitive to the implant size and femoral width. Furthermore, different rankings of implant performance were predicted when only individual simulations (e.g. an average condition) were used to rank implants, compared with when stochastic simulations were used. In conclusion, the proposed framework provides a viable approach to predicting realistic ranges of loosening behaviour for orthopaedic implants in reduced timeframes compared with conventional Monte Carlo simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background:Research examining the relationship between adiponectin (AN) isoforms, body weight and cardiovascular (CV) risk factors is limited, particularly in younger populations. Objectives:To investigate the inter-relationships between AN isoforms and CV risk factors, and their dependence on body weight status, in adolescents. Design:Blood samples from 92 obese, 92 overweight and 92 normal weight age- and sex-matched adolescents were analysed for traditional cardiovascular disease (CVD) risk biomarkers and also total, high molecular weight (HMW), medium and low molecular weight (LMW) AN. Results:A significant inverse association was observed between total and HMW AN and waist-hip ratio (P=0.015, P=0.006, respectively), triglycerides (P=0.003, P=0.003, respectively) and systolic blood pressure (P=0.012, P=0.024, respectively) and a significant positive association with high-density lipoprotein (P<0.001, P<0.001, respectively) in multi-adjusted analyses. There was no evidence of a relationship between multimeric AN and high-sensitivity C-reactive protein. There was also little evidence of a relationship between LMW AN and CVD risk factors. There was a strong, body mass index (BMI)-independent, association between AN, CVD biomarkers and the hypertriglyceridemic waist phenotype. Conclusion:Prominent, BMI-independent associations between total and HMW AN, but not LMW AN, and CVD risk factors were already evident in this young population. This research in adolescents supports the contention that AN subfractions may have different biological actions. These associations in apparently healthy adolescents suggest an important role for AN and its subfractions in the pathogenesis of metabolic syndrome traits and indicate that the potential for total or HMW AN to act as early universal biomarkers of CV risk warrants further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a series of 706 patients (759 hip implants) with an average follow up of 10.5 years (range, 10-11 years) following total hip replacement (THR) using a cemented custom-made femoral stem and a cemented HDP acetabular component. The fate of every implant is known. One hundred and seventy-four patients (23%) were deceased at the time of their 10-year review all died with a functioning THR in situ. Four hundred and sixty-two patients (61%) were subsequently reviewed. One hundred and twenty three patients (16%) were assessed by telephone review, as they were too ill or unwilling to attend. Kaplan-Meier survival analysis (all components) demonstrated a median survival at 10 years of 96.05% or 95% Confidence Intervals (CI) for median survival of (94.41% to 97.22%). Revision surgery occurred in 30 cases (3.9%). Seventeen had full revisions (2.2%) and 13 (1.7%) socket revisions only. Twenty-one out of 30 revisions were for infection or dislocation. There were 2 cases (0.3%) of revision for aseptic loosening of the stem. The 10-year results of the custom femoral titanium stem are encouraging and compare well with other cemented systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability to measure acetabular cup orientation accurately during total hip arthroplasty represents a significant challenge. The aim of this research was to develop and evaluate a novel low cost mechanical device for measuring operative acetabular inclination. Cup implantation was simulated in two trials using the novel device: firstly involving surgeons and engineers orientating acetabular cups with sawbone pelves at a range of inclination angles (20°-55° in 5° increments); secondly in a simulated intra-operative scenario with surgeons. Target angles were compared with achieved angles and deviations from desired angles were recorded. In addition, all participants orientated cups under the same conditions using two other techniques: freehand and with a propriatory Mechanical Alignment Guide. In the first trial, the mean errors (deviations) using freehand technique, the mechanical alignment guide and the new device were 5.2° +/- 4.3° (range 0.1-22.0), 3.6° +/- 3.9° (range 0.1°-33.6°) and 0.5° +/- 0.4° (range 0.0-1.9) respectively. In the second trial, the mean error for freehand technique, mechanical alignment guide and the new device were 6.2° +/- 4.2° (range 0.2-18.2), 3.8° +/- 3.3° (range 0.0-19.1) and 0.6° +/- 0.5° (range 0.0-1.8) respectively. The new device has the potential to allow the surgeon to choose and record operative inclination accurately during total hip arthroplasty in the lateral decubitus position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim of this study was to assess the efficacy, tolerability and safety of risedronate in adults with CF. Methods: Patients with a lumbar spine (LS), total hip (TH) or femoral neck (FN) bone mineral density (BMD) Z-score of -1 or less were randomised to receive risedronate 35mg weekly or placebo, and calcium (1g)+vitamin D (800IU). Results: At baseline, BMD Z-scores in the risedronate (n = 17) and placebo (n = 19) groups were similar. By 24. months, 7/17 risedronate patients vs 0/19 placebo patients stopped the study medication due to bone pain. After 24. months treatment, the mean difference (95% CI) in change in LS, TH and FN BMD between the risedronate vs placebo groups was 4.3% (0.4, 8.2) p = 0.03; 4.0% (-0.5, 8.6) p = 0.08; and 2.4% (-3.5, 8.2) p =0.41. Conclusions: After two years treatment there was a significant increase in LS BMD with weekly risedronate compared to placebo. © 2011 European Cystic Fibrosis Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The incidence of oesophageal adenocarcinoma (EAC) has increased rapidly over the past 40 years and accumulating evidence suggests that obesity, as measured by body mass index (BMI), is a major risk factor. It remains unclear whether abdominal obesity is associated with EAC and gastric adenocarcinoma.

Design: Cox proportional hazards regression was used to examine associations between overall and abdominal obesity with EAC and gastric adenocarcinoma among 218 854 participants in the prospective NIHeAARP cohort.

Results: 253 incident EAC, 191 gastric cardia adenocarcinomas and 125 gastric non-cardia adenocarcinomas accrued to the cohort. Overall obesity (BMI) was positively associated with EAC and gastric
cardia adenocarcinoma risk (highest ($35 kg/m2) vs referent (18.5e<25 kg/m2); HR 2.11, 95% CI 1.09 to 4.09 and HR 3.67, 95% CI 2.00 to 6.71, respectively). Waist circumference was also positively associated with EAC and gastric cardia adenocarcinoma risk (highest vs referent; HR 2.01, 95% CI 1.35 to 3.00 and HR 2.22, 95% CI 1.43 to 3.47, respectively), whereas waist-to-hip ratio (WHR) was positively associated with EAC risk only (highest vs referent; HR 1.81, 95% CI 1.24 to 2.64) and persisted in patients with normal BMI (18.5e<25 kg/m2). Mutual adjustment of WHR and BMI attenuated
both, but did not eliminate the positive associations for either with risk of EAC. In contrast, the majority of the anthropometric variables were not associated with adenocarcinomas of the gastric non-cardia.

Conclusion Overall obesity was associated with a higher risk of EAC and gastric cardia adenocarcinoma, whereas abdominal obesity was found to be associated with increased EAC risk; even in people with normal BMI

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To determine if serum pigment epithelium-derived factor (PEDF) levels in Type 2 diabetes are related to vascular risk factors and renal function. Methods: PEDF was quantified by ELISA in a cross-sectional study of 857 male Veterans Affairs Diabetes Trial (VADT) subjects, and associations with cardiovascular risk factors and renal function were determined. In a subset (n = 246) in whom serum was obtained early in the VADT (2.0 ± 0.3 years post-randomization), PEDF was related to longitudinal changes in renal function over 3.1 years. Results: Cross-sectional study: In multivariate regression models, PEDF was positively associated with serum triglycerides, waist-to-hip ratio, serum creatinine, use of ACE inhibitors or angiotensin receptor blockers, and use of lipid-lowering agents; it was negatively associated with HDL-C (all p < 0.05). Longitudinal study: PEDF was not associated with changes in renal function over 3.1 years (p > 0.09). Conclusions: Serum PEDF in Type 2 diabetic men was cross-sectionally associated with dyslipidemia, body habitus, use of common drugs for blood pressure and dyslipidemia, and indices of renal function; however, PEDF was not associated with renal decline over 3.1 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Russia has very high mortality from cardiovascular disease (CVD), with evidence that heavy drinking may play a role. To throw further light on this association we have studied the association of alcohol with predictors of CVD risk including B-type natriuretic peptide (BNP). Levels of BNP increase primarily in response to abnormal cardiac chamber wall stretch which can occur both as a result of atherosclerosis as well as due to other types of damage to the myocardium. No previous population-based studies have investigated the association with alcohol. We analysed cross-sectional data on drinking behaviour in 993 men aged 25-60 years from the Izhevsk Family Study 2 (IFS2), conducted in the Russian city of Izhevsk in 2008-2009. Relative to non-drinkers, men who drank hazardously had an odds ratio (OR) of being in the top 20 % of the BNP distribution of 4.66 (95 % CI 2.13, 10.19) adjusted for age, obesity, waist-hip ratio, and smoking. Further adjustment for class of hypertension resulted in only slight attenuation of the effect, suggesting that this effect was not secondary to the influence of alcohol on blood pressure. In contrast hazardous drinking was associated with markedly raised ApoA1 and HDL cholesterol levels, but had little impact on levels of ApoB and LDL cholesterol. Similar but less pronounced associations were found in the Belfast (UK) component of the PRIME study conducted in 1991. These findings suggest that the association of heavy drinking with increased risk of cardiovascular disease may be partly due to alcohol-induced non-atherosclerotic damage to the myocardium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Propionibacterium acnes and coagulase-negative staphylococci (CoNS) are opportunistic pathogens implicated in prosthetic joint and fracture fixation device-related infections. The purpose of this study was to determine whether P. acnes and the CoNS species Staphylococcus lugdunensis, isolated from an "aseptically failed" prosthetic hip joint and a united intramedullary nail-fixed tibial fracture, respectively, could cause osteomyelitis in an established implant-related osteomyelitis model in rabbits in the absence of wear debris from the implant material. The histological features of P. acnes infection in the in vivo rabbit model were consistent with localized pyogenic osteomyelitis, and a biofilm was present on all explanted intramedullary (IM) nails. The animals displayed no outward signs of infection, such as swelling, lameness, weight loss, or elevated white blood cell count. In contrast, infection with S. lugdunensis resulted in histological features consistent with both pyogenic osteomyelitis and septic arthritis, and all S. lugdunensis-infected animals displayed weight loss and an elevated white blood cell count despite biofilm detection in only two out of six rabbits. The differences in the histological and bacteriological profiles of the two species in this rabbit model of infection are reflective of their different clinical presentations: low-grade infection in the case of P. acnes and acute infection for S. lugdunensis. These results are especially important in light of the growing recognition of chronic P. acnes biofilm infections in prosthetic joint failure and nonunion of fracture fixations, which may be currently reported as "aseptic" failure. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Approaches exploiting trait distribution extremes may be used to identify loci associated with common traits, but it is unknown whether these loci are generalizable to the broader population. In a genome-wide search for loci associated with the upper versus the lower 5th percentiles of body mass index, height and waist-to-hip ratio, as well as clinical classes of obesity, including up to 263,407 individuals of European ancestry, we identified 4 new loci (IGFBP4, H6PD, RSRC1 and PPP2R2A) influencing height detected in the distribution tails and 7 new loci (HNF4G, RPTOR, GNAT2, MRPS33P4, ADCY9, HS6ST3 and ZZZ3) for clinical classes of obesity. Further, we find a large overlap in genetic structure and the distribution of variants between traits based on extremes and the general population and little etiological heterogeneity between obesity subgroups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wear and corrosion of metal-on-metal hip replacements results in wear debris and metal-ion release in vivo, which may subsequently cause pain and hypersensitivity for patients. Retrieved metal-on-metal hip replacements have revealed that two-body sliding wear and three-body abrasive wear are the predominant wear mechanisms. However, there is a lack of understanding of the combined effects of wear/corrosion, especially the effect of abrasion-corrosion.

This study investigates the sliding-corrosion and abrasion-corrosion performance of a cast CoCrMo alloy in simulated hip joint environments using a microabrasion rig integrated with an electrochemical cell. Tests have been conducted in 0.9% NaCl, phosphate buffered saline solution, 25% and 50% bovine serum solutions with 0 or 1 g cm(-3) SiC at 37 degrees C. Experimental results reveal that under abrasion-corrosion test conditions, the presence of proteins increased the total specific wear rate. Conversely, electrochemical noise measurements indicated that the average anodic current levels were appreciably lower for the proteinaceous solutions when compared with the inorganic solutions. A severely deformed nanocrystalline layer was identified immediately below the worn surface for both proteinaceous and inorganic solutions. The layer is formed by a recrystallisation process and/or a strain-induced phase transformation that occurs during microabrasion-corrosion. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The abrasion seen on some of the retrieved CoCrMo hip joints has been reported to be caused by entrained hard particles in vivo. However, little work has been reported on the abrasion mechanisms of CoCrMo alloy in simulated body environments. Therefore. this study covers the mapping of micro-abrasion wear mechanisms of cast CoCrMo induced by third body hard particles under a wide range of abrasive test conditions. This study has a specific focus on covering the possible in vivo wear modes seen on metal-on-metal (MoM) surfaces. Nano-indentation and nano-scratch tests were also employed to further investigate the secondary wear mechanisms-nano-scale material deformation that involved in micro-abrasion processes. This work addresses the potential detrimental effects of third body hard particles in vivo such as increased wear rates (debris generation) and corrosion (metal-ion release). The abrasive wear mechanisms of cast CoCrMo have been investigated under various wear-corrosion conditions employing two abrasives, SiC (similar to 4 mu m) and Al(2)O(3) (similar to 1 mu m), in two test solutions, 0.9% NaCl and 25% bovine serum. The specific wear rates, wear mechanisms and transitions between mechanisms are discussed in terms of the abrasive size, volume fraction and the test solutions deployed. The work shows that at high abrasive volume fractions, the presence of protein enhanced the wear loss due to the enhanced particle entrainment, whereas at much lower abrasive volume fractions, protein reduced the wear loss by acting as a boundary lubricant or rolling elements which reduced the abrasivity (load per particle) of the abrasive particles. The abrasive wear rate and wear mechanisms of the CoCrMo are dependent on the nature of the third body abrasives, their entrainment into the contact and the presence of the proteins. (C) 2009 Elsevier B.V. All rights reserved.