110 resultados para Color vision


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Law and development, as both movement and practice, has led a tumultuous life: a hurried zenith cut short by a fatal critique followed by an opportunistic resurrection. The name alone is su?cient to trigger a range of reactions, extending from the complimentary to the condemnatory. In this article I track law and development’s evolution via an examination of its role in the remodelling of Egyptian society in the post-Nasser era. While the 2011 revolution has encouraged institutions such as USAID to hasten their legal reform e?orts, I argue that these are more akin to counter-revolution by ideology than genuine revolution by law. Nevertheless, rather than relegate the movement to the annals of imperial intrigue, I conclude by proposing the use of legal pluralism to revive, and possibly ignite, law and development’s emancipatory potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We employ the time-dependent R-matrix (TDRM) method to calculate anisotropy parameters for positive and negative sidebands of selected harmonics generated by two-color two-photon above-threshold ionization of argon. We consider odd harmonics of an 800-nm field ranging from the 13th to 19th harmonic, overlapped by a fundamental 800-nm IR field. The anisotropy parameters obtained using the TDRM method are compared with those obtained using a second-order perturbation theory with a model potential approach and a soft photon approximation approach. Where available, a comparison is also made to published experimental results. All three theoretical approaches provide similar values for anisotropy parameters. The TDRM approach obtains values that are closest to published experimental values. At high photon energies, the differences between each of the theoretical methods become less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart Spaces, Ambient Intelligence, and Ambient Assisted Living are environmental paradigms that strongly depend on their capability to recognize human actions. While most solutions rest on sensor value interpretations and video analysis applications, few have realized the importance of incorporating common-sense capabilities to support the recognition process. Unfortunately, human action recognition cannot be successfully accomplished by only analyzing body postures. On the contrary, this task should be supported by profound knowledge of human agency nature and its tight connection to the reasons and motivations that explain it. The combination of this knowledge and the knowledge about how the world works is essential for recognizing and understanding human actions without committing common-senseless mistakes. This work demonstrates the impact that episodic reasoning has in improving the accuracy of a computer vision system for human action recognition. This work also presents formalization, implementation, and evaluation details of the knowledge model that supports the episodic reasoning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a critical review of the literature surrounding the potential impact of undiagnosed and untreated vision impairment on reading development in the early years of primary school. Despite pre-school screening programmes, it is still possible for children to enter school with undiagnosed, uncorrected vision impairments. This can be due to health care access issues for children. Data reviewed indicated correlations between hyperopic vision impairment and poor reading development. However, the relationships reported remain complex, with myopic vision impairment being reported to correlate to high reading ability in some studies. In addition, correlation does not necessarily imply causation. Previous research in the field is reported. Deficiencies in the current literature base are discussed. Finally, recommendations for teaching practice and the nature of research that explores whether vision impairment is the cause of poor reading development for some children in school is suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distinct neural populations carry signals from short-wave (S) cones. We used individual differences to test whether two types of pathways, those that receive excitatory input (S+) and those that receive inhibitory input (S-), contribute independently to psychophysical performance. We also conducted a genome-wide association study (GWAS) to look for genetic correlates of the individual differences. Our psychophysical test was based on the Cambridge Color Test, but detection thresholds were measured separately for S-cone spatial increments and decrements. Our participants were 1060 healthy adults aged 16-40. Test-retest reliabilities for thresholds were good (ρ=0.64 for S-cone increments, 0.67 for decrements and 0.73 for the average of the two). "Regression scores," isolating variability unique to incremental or decremental sensitivity, were also reliable (ρ=0.53 for increments and ρ=0.51 for decrements). The correlation between incremental and decremental thresholds was ρ=0.65. No genetic markers reached genome-wide significance (p-7). We identified 18 "suggestive" loci (p-5). The significant test-retest reliabilities show stable individual differences in S-cone sensitivity in a normal adult population. Though a portion of the variance in sensitivity is shared between incremental and decremental sensitivity, over 26% of the variance is stable across individuals, but unique to increments or decrements, suggesting distinct neural substrates. Some of the variability in sensitivity is likely to be genetic. We note that four of the suggestive associations found in the GWAS are with genes that are involved in glucose metabolism or have been associated with diabetes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe associations between reticular pseudodrusen, individual characteristics, and retinal function.

Design: Cohort study.

Participants: We recruited 105 patients (age range, 52–93 years) who had advanced neovascular age-related macular degeneration (AMD) in only 1 eye from 3 clinical centers in Europe.

Methods: Minimum follow-up was 12 months. The eye selected for study was the fellow eye without advanced disease. Clinical measures of vision were distance visual acuity, near visual acuity, and results of the Smith-Kettlewell low-luminance acuity test (SKILL). Fundus imaging included color photography, red-free imaging, blue autofluorescence imaging, fluorescein angiography, indocyanine green angiography, and optical coherence tomography using standardized protocols. These were used to detect progression to neovascular AMD in the study eye during follow-up. All imaging outputs were graded for the presence or absence of reticular pseudodrusen (RPD) using a multimodal approach. Choroidal thickness was measured at the foveal center and at 2 other equidistant locations from the fovea (1500 μm) nasally and temporally. Metrics on retinal thickness and volume were obtained from the manufacturer-supplied automated segmentation readouts.

Main Outcome Measures: Presence of RPD, distance visual acuity, near visual acuity, SKILL score, choroidal thickness, retinal thickness, and retinal volume.

Results: Reticular pseudodrusen was found in 43 participants (41%) on 1 or more imaging method. The SKILL score was significantly worse in those with reticular drusen (mean score ± standard deviation [SD, 38±12) versus those without (mean score ± SD, 33±9) (P = 0.034). Parafoveal retinal thickness, parafoveal retinal volume, and all of the choroidal thickness parameters measured were significantly lower in those with reticular drusen than in those without. The presence of RPD was associated with development of neovascular AMD when corrected for age and sex (odds ratio, 5.5; 95% confidence interval, 1.1–28.8; P = 0.042). All participants in whom geographic atrophy developed during follow-up had visible RPD at baseline.

Conclusions: Significant differences in retinal and choroidal anatomic features, visual function, and risk factor profile exist in unilateral neovascular AMD patients with RPD compared with those without; therefore, such patients should be monitored carefully because of the risk of developing bilateral disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Historically, drusen, which are recognized as the hallmark of age-related macular degeneration (AMD), have been described in terms of size, margins, and texture, and several studies have emphasized the importance of large soft drusen particularly when combined with focal pigmentary irregularities in determining the risk of progression to neovascular AMD. However, recent developments in imaging over the past decade have revealed a further distinct phenotype strongly associated with the development of late AMD, namely, reticular pseudodrusen (RPD) or reticular drusen. Reticular pseudodrusen appear as yellowish interlacing networks in the fundus and, although visible on color photography, are better visualized using infrared imaging or spectral domain optical coherence tomography. Studies correlating spectral domain optical coherence tomography and confocal scanning laser ophthalmoscopy have shown that RPD are subretinal deposits located internal to the retinal pigment epithelium in contrast to traditional drusen, which are located external to the retinal pigment epithelium. As multiple longitudinal studies have revealed RPD are strong predictors for progression to both neovascular AMD and geographic atrophy, the interest in understanding the role that RPD play in the pathogenesis of AMD has grown. This review focuses on the current literature concerning RPD and considers what is currently known regarding their epidemiology, risk factors, appearance in both retinal imaging and histology, impact on visual function, relationship to other AMD lesions, and association with the development of late AMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power dissipation and robustness to process variation have conflicting design requirements. Scaling of voltage is associated with larger variations, while Vdd upscaling or transistor upsizing for parametric-delay variation tolerance can be detrimental for power dissipation. However, for a class of signal-processing systems, effective tradeoff can be achieved between Vdd scaling, variation tolerance, and output quality. In this paper, we develop a novel low-power variation-tolerant algorithm/architecture for color interpolation that allows a graceful degradation in the peak-signal-to-noise ratio (PSNR) under aggressive voltage scaling as well as extreme process variations. This feature is achieved by exploiting the fact that all computations used in interpolating the pixel values do not equally contribute to PSNR improvement. In the presence of Vdd scaling and process variations, the architecture ensures that only the less important computations are affected by delay failures. We also propose a different sliding-window size than the conventional one to improve interpolation performance by a factor of two with negligible overhead. Simulation results show that, even at a scaled voltage of 77% of nominal value, our design provides reasonable image PSNR with 40% power savings. © 2006 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power dissipation and tolerance to process variations pose conflicting design requirements. Scaling of voltage is associated with larger variations, while Vdd upscaling or transistor up-sizing for process tolerance can be detrimental for power dissipation. However, for certain signal processing systems such as those used in color image processing, we noted that effective trade-offs can be achieved between Vdd scaling, process tolerance and "output quality". In this paper we demonstrate how these tradeoffs can be effectively utilized in the development of novel low-power variation tolerant architectures for color interpolation. The proposed architecture supports a graceful degradation in the PSNR (Peak Signal to Noise Ratio) under aggressive voltage scaling as well as extreme process variations in. sub-70nm technologies. This is achieved by exploiting the fact that some computations are more important and contribute more to the PSNR improvement compared to the others. The computations are mapped to the hardware in such a way that only the less important computations are affected by Vdd-scaling and process variations. Simulation results show that even at a scaled voltage of 60% of nominal Vdd value, our design provides reasonable image PSNR with 69% power savings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in hardware development coupled with the rapid adoption and broad applicability of cloud computing have introduced widespread heterogeneity in data centers, significantly complicating the management of cloud applications and data center resources. This paper presents the CACTOS approach to cloud infrastructure automation and optimization, which addresses heterogeneity through a combination of in-depth analysis of application behavior with insights from commercial cloud providers. The aim of the approach is threefold: to model applications and data center resources, to simulate applications and resources for planning and operation, and to optimize application deployment and resource use in an autonomic manner. The approach is based on case studies from the areas of business analytics, enterprise applications, and scientific computing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pupose. To evaluate the relationship between retinal vascular caliber (RVC), iris color and age-related macular degeneration (AMD) in elderly Irish nuns. Methods. Data from 1233 participants in the cross-sectional observational Irish Nun Eye Study were assessed from digital photographs with a standardized protocol using computer-assisted software. Macular images were graded according to the modified Wisconsin age-related maculopathy grading system. Regression models were used to assess associations, adjusting for age, mean arterial blood pressure, body mass index, refraction and fellow RVC. Results. In total, 1122 (91%) participants had gradable retinal images of sufficient quality for vessel assessment (mean age: 76.3 years [range: 56-100 years]). In an unadjusted analysis, we found some support for a previous finding that individuals with blue iris color had narrower retinal venules compared to those with brown iris color (P<0.05) but this was no longer significant after adjustment. AMD status was categorized as no AMD, any AMD and late AMD only. Individuals with any AMD (early or late AMD) had significantly narrower arterioles and venules compared to those with no AMD in an unadjusted analysis but this was no longer significant after adjustment. A non-significant reduced risk of any AMD or late AMD only was observed in association with brown compared to blue iris color, in both unadjusted and adjusted analyses. Conclusions. RVC was not significantly associated with iris color or early/late AMD after adjustment for confounders. A lower but non-significant AMD risk was observed in those with brown compared to blue iris color.