73 resultados para iris


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Obesity is heritable and predisposes to many diseases. To understand the genetic basis of obesity better, here we conduct a genome-wide association study and Metabochip meta-analysis of body mass index (BMI), a measure commonly used to define obesity and assess adiposity, in up to 339,224 individuals. This analysis identifies 97 BMI-associated loci (P < 5 × 10(-8)), 56 of which are novel. Five loci demonstrate clear evidence of several independent association signals, and many loci have significant effects on other metabolic phenotypes. The 97 loci account for ∼2.7% of BMI variation, and genome-wide estimates suggest that common variation accounts for >20% of BMI variation. Pathway analyses provide strong support for a role of the central nervous system in obesity susceptibility and implicate new genes and pathways, including those related to synaptic function, glutamate signalling, insulin secretion/action, energy metabolism, lipid biology and adipogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Age-related macular degeneration (AMD) is the leading cause of blindness among white caucasians over the age of 50 years with a prevalence rate expected to increase markedly with an anticipated increase in the life span of the world population. To further expand our knowledge of the genetic architecture of the disease, we pursued a candidate gene approach assessing 25 genes and a total of 109 variants. Of these, synonymous single nucleotide polymorphism (SNP) rs17810398 located in death-associated protein-like 1 (DAPL1) was found to be associated with AMD in a joint analysis of 3,229 cases and 2,835 controls from five studies [combined P ADJ = 1.15 × 10(-6), OR 1.332 (1.187-1.496)]. This association was characterized by a highly significant sex difference (P diff = 0.0032) in that it was clearly confined to females with genome-wide significance [P ADJ = 2.62 × 10(-8), OR 1.541 (1.324-1.796); males: P ADJ = 0.382, OR 1.084 (0.905-1.298)]. By targeted resequencing of risk and non-risk associated haplotypes in the DAPL1 locus, we identified additional potentially functional risk variants, namely a common 897-bp deletion and a SNP predicted to affect a putative binding site of an exonic splicing enhancer. We show that the risk haplotype correlates with a reduced retinal transcript level of two, less frequent, non-canonical DAPL1 isoforms. DAPL1 plays a role in epithelial differentiation and may be involved in apoptotic processes thereby suggesting a possible novel pathway in AMSaveD pathogenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The past three decades have seen rapid improvements in the diagnosis and treatment of most cancers and the most important contributor has been research. Progress in rare cancers has been slower, not least because of the challenges of undertaking research.

SETTINGS: The International Rare Cancers Initiative (IRCI) is a partnership which aims to stimulate and facilitate the development of international clinical trials for patients with rare cancers. It is focused on interventional--usually randomized--clinical trials with the clear goal of improving outcomes for patients. The key challenges are organisational and methodological. A multi-disciplinary workshop to review the methods used in ICRI portfolio trials was held in Amsterdam in September 2013. Other as-yet unrealised methods were also discussed.

RESULTS: The IRCI trials are each presented to exemplify possible approaches to designing credible trials in rare cancers. Researchers may consider these for use in future trials and understand the choices made for each design.

INTERPRETATION: Trials can be designed using a wide array of possibilities. There is no 'one size fits all' solution. In order to make progress in the rare diseases, decisions to change practice will have to be based on less direct evidence from clinical trials than in more common diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Novel nucleoside analogues containing photoswitchable moieties were prepared using 'click' cycloaddition reactions between 5 '-azido-5 '-deoxythymidine and mono- or bis-N-propargylamide-substituted azobenzenes. In solution, high to quantitative yields were achieved using 5mol% Cu(I) in the presence of a stabilizing ligand. 'Click' reactions using the monopropargylamides were also effected in the absence of added cuprous salts by the application of liquid assisted grinding (LAG) in metallic copper reaction vials. Specifically, high speed vibration ball milling (HSVBM) using a 3/32('') (2.38mm) diameter copper ball (62mg) at 60Hz overnight in the presence of ethyl acetate lead to complete consumption of the 5 '-azido nucleoside with clean conversion to the corresponding 1,3-triazole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A highly sensitive and specific competitive ELISA on 96-microwell plates was developed for the analysis of the nonsteroidal anti-inflammatory drug diclofenac. Within the water cycle in Europe, this is one of the most frequently detected pharmaceutically active compounds. The LOD at a signal-tonoise ratio (S/N) of 3, and the IC 50, were found to be 6 ng/L and 60 ng/L respectively in tap water. In a comparative study using ELISA and GC-MS, diclofenac levels in wastewater from 21 sewage treatment plants were determined and a good correlation between these methods was found (ELISA vs. GCMS: r = 0.70, slope = 0,90, intercept = 0.37, n = 24). An average degradation rate of -25% can be calculated. Labscale-experiments on the elimination of diclofenac in continuous pilot sewage plants revealed a removal rate of only 5% over a period of 13 weeks. In a further study, the ELISA was applied to a number of extracts of various animal tissues from a range of species, and again a very good relationship between ELISA and LC-ESI/MS data sets was obtained (r = 0.90, p<0.0001; n = 117). The ELISA has proven to be a simple, rapid, reliable and affordable alternative to otherwise costly and advanced techniques for the detection of diclofenac in matrix diverse water samples and tissue extracts after only relatively simple sample preparation. © 2007 American Chemical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To study the population distribution and longitudinal changes in anterior chamber angle width and its determinants among Chinese adults. Design: Prospective cohort, population-based study. Participants: Persons aged 35 years or more residing in Guangzhou, China, who had not previously undergone incisional or laser eye surgery. Methods: In December 2008 and December 2010, all subjects underwent automated keratometry, and a random 50% sample had anterior segment optical coherence tomography with measurement of angle-opening distance at 500 μm (AOD500), angle recess area (ARA), iris thickness at 750 μm (IT750), iris curvature, pupil diameter, corneal thickness, anterior chamber width (ACW), lens vault (LV), and lens thickness (LT) and measurement of axial length (AL) and anterior chamber depth (ACD) by partial coherence laser interferometry. Main Outcome Measures: Baseline and 2-year change in AOD500 and ARA in the right eye. Results: A total of 745 subjects were present for full biometric testing in both 2008 and 2010 (mean age at baseline, 52.2 years; standard deviation [SD], 11.5 years; 53.7% were female). Test completion rates in 2010 varied from 77.3% (AOD500: 576/745) to 100% (AL). Mean AOD500 decreased from 0.25 mm (SD, 0.13 mm) in 2008 to 0.21 mm (SD, 13 mm) in 2010 (difference, -0.04; 95% confidence interval [CI], -0.05 to -0.03). The ARA decreased from 21.5±3.73 10-2 mm2 to 21.0±3.64 10 -2 mm2 (difference, -0.46; 95% CI, -0.52 to -0.41). The decrease in both was most pronounced among younger subjects and those with baseline AOD500 in the widest quartile at baseline. The following baseline variables were significantly associated with a greater 2-year decrease in both AOD500 and ARA: deeper ACD, steeper iris curvature, smaller LV, greater ARA, and greater AOD500. By using simple regression models, we could explain 52% to 58% and 93% of variation in baseline AOD500 and ARA, respectively, but only 27% and 16% of variation in 2-year change in AOD500 and ARA, respectively. Conclusions: Younger persons and those with the least crowded anterior chambers at baseline have the largest 2-year decreases in AOD500 and ARA. The ability to predict change in angle width based on demographic and biometric factors is relatively poor, which may have implications for screening. Financial Disclosure(s): The author(s) have no proprietary or commercial interest in any materials discussed in this article. © 2012 American Academy of Ophthalmology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impact of laser peripheral iridotomy (LPI) on forward-scatter of light and subjective visual symptoms and to identify LPI parameters influencing these phenomena. DESIGN: Cohort study derived from a randomized trial, using an external control group. PARTICIPANTS: Chinese subjects initially aged 50 or older and 70 years or younger with bilateral narrow angles undergoing LPI in 1 eye selected at random, and age- and gender-matched controls. METHODS: Eighteen months after laser, LPI-treated subjects underwent digital iris photography and photogrammetry to characterize the size and location of the LPI, Lens Opacity Classification System III cataract grading, and measurement of retinal straylight (C-Quant; OCULUS, Wetzlar, Germany) in the treated and untreated eyes and completed a visual symptoms questionnaire. Controls answered the questionnaire and underwent straylight measurement and (in a random one-sixth sample) cataract grading. MAIN OUTCOME MEASURES: Retinal straylight levels and subjective visual symptoms. RESULTS: Among 230 LPI-treated subjects (121 [58.8%] with LPI totally covered by the lid, 43 [19.8%] with LPI partly covered by the lid, 53 [24.4%] with LPI uncovered by the lid), 217 (94.3%) completed all testing, as did 250 (93.3%) of 268 controls. Age, gender, and prevalence of visual symptoms did not differ between treated subjects and controls, although nuclear (P<0.01) and cortical (P = 0.03) cataract were less common among controls. Neither presenting visual acuity nor straylight score differed between the treated and untreated eyes among all treated persons, nor among those (n = 96) with LPI partially or totally uncovered. Prevalence of subjective glare did not differ significantly between participants with totally covered LPI (6.61%; 95% confidence interval [CI], 3.39%-12.5%), partially covered LPI (11.6%; 95% CI, 5.07%-24.5%), or totally uncovered LPI (9.43%; 95% CI, 4.10%-10.3%). In regression models, only worse cortical cataract grade (P = 0.01) was associated significantly with straylight score, and no predictors were associated with subjective glare. None of the LPI size or location parameters were associated with straylight or subjective symptoms. CONCLUSIONS: These results suggests that LPI is safe regarding measures of straylight and visual symptoms. This randomized design provides strong evidence that treatment programs for narrow angles would be unlikely to result in important medium-term visual disability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE:

To design a system of gonioscopy that will allow greater interobserver reliability and more clearly defined screening cutoffs for angle closure than current systems while being simple to teach and technologically appropriate for use in rural Asia, where the prevalence of angle-closure glaucoma is highest.

DESIGN:

Clinic-based validation and interobserver reliability trial.

PARTICIPANTS:

Study 1: 21 patients 18 years of age and older recruited from a university-based specialty glaucoma clinic; study 2: 32 patients 18 years of age and older recruited from the same clinic.

INTERVENTION:

In study 1, all participants underwent conventional gonioscopy by an experienced observer (GLS) using the Spaeth system and in the same eye also underwent Scheimpflug photography, ultrasonographic measurement of anterior chamber depth and axial length, automatic refraction, and biometric gonioscopy with measurement of the distance from iris insertion to Schwalbe's line using a reticule based in the slit-lamp ocular. In study 2, all participants underwent both conventional gonioscopy and biometric gonioscopy by an experienced gonioscopist (NGC) and a medical student with no previous training in gonioscopy (JK).

MAIN OUTCOME MEASURES:

Study 1: The association between biometric gonioscopy and conventional gonioscopy, Scheimpflug photography, and other factors known to correlate with the configuration of the angle. Study 2: Interobserver agreement using biometric gonioscopy compared to that obtained with conventional gonioscopy.

RESULTS:

In study 1, there was an independent, monotonic, statistically significant relationship between biometric gonioscopy and both Spaeth angle (P = 0.001, t test) and Spaeth insertion (P = 0.008, t test) grades. Biometric gonioscopy correctly identified six of six patients with occludable angles according to Spaeth criteria. Biometric gonioscopic grade was also significantly associated with the anterior chamber angle as measured by Scheimpflug photography (P = 0.005, t test). In study 2, the intraclass correlation coefficient between graders for biometric gonioscopy (0.97) was higher than for Spaeth angle grade (0.72) or Spaeth insertion grade (0.84).

CONCLUSION:

Biometric gonioscopy correlates well with other measures of the anterior chamber angle, shows a higher degree of interobserver reliability than conventional gonioscopy, and can readily be learned by an inexperienced observer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM:

To utilise a novel method for making measurements in the anterior chamber in order to compare the anterior chamber angles of people of European, African, and east Asian descent aged 40 years and over.

METHODS:

A cross sectional study on 15 people of each sex from each decade from the 40s to the 70s, from each of three racial groups-black, white, and Chinese Singaporeans. Biometric gonioscopy (BG) utilises a slit lamp mounted reticule to make measurements from the apparent iris insertion to Schwalbe's line through a Goldmann one mirror goniolens. The main outcome measures were BG measurements of the anterior chamber angle as detailed above.

RESULTS:

There was no significant difference in angle measurement between black, white, and Chinese races in this study. However, at younger ages people of Chinese race appeared to have deeper angles than white or black people, whereas the angles of older Chinese were significantly narrower (p = 0.004 for the difference in slope of BG by age between Chinese and both black and white people).

CONCLUSION:

The failure to detect a difference in angle measurements between these groups was surprising, given the much higher prevalence of angle closure among Chinese. It appears that the overall apparent similarity of BG means between Chinese and Western populations may mask very different trends with age. The apparently more rapid decline in angle width measurements with age among Chinese may be due to the higher prevalence of cataract or "creeping angle closure." However, longitudinal inferences from cross sectional data are problematic, and this may represent a cohort phenomenon caused by the increasing prevalence of myopia in the younger Singaporean population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To clarify the risk parameters measured by anterior segment optical coherence tomography (AS-OCT) for elevated intraocular pressures (IOP) provoked by the darkroom test and to provide recommendations for its clinical usage. METHODS: Subjects aged >40 years and whose peripheral anterior chambers were ≤1/4 corneal thickness were recruited. The anterior segment of the eye was imaged in sitting position and under both light and dark conditions and biometry was performed using anterior segment optical coherence tomography. The analyzed parameters were: (1) central anterior chamber depth (ACD); (2) anterior chamber width; (3) pupil diameter; (4) iris curvature; (5) lens thickness; and (6) number of meridians with closed angles (NCA). Then the darkroom test was performed and a positive provocative test result was defined as a rise in IOP ≥8 mm Hg after the test. Statistical analyses included: (1) the difference in parameters between positive and negative eyes; (2) the association between posttest IOP and the parameters; and (3) the difference in parameters between the 2 eyes in subjects with the asymmetric results. RESULTS: A total of 70 subjects were recruited. ACD (P=0.022), NCA in light (P<0.001), and NCA in dark (P<0.001) were different significantly between eyes with positive and negative results. There was a strong association between NCA in dark (r=0.755, P<0.001) and the posttest IOP. Among subjects with asymmetric results between the 2 eyes, the ACD was shallower and the lens thickness was larger in the positive eye. CONCLUSIONS: The posttest IOP is determined by the extent of functionally closed angles in the dark. The test may be useful in the early diagnosis of primary angle closure. At the same time, angle configuration should be evaluated to remove false positive result.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS: 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadrants during dark room gonioscopy) in each group, were consecutively enrolled. One eye of each subject was randomly selected for imaging in a completely darkened room. Measurements, including anterior chamber depth (ACD), scleral spur-to-scleral spur distance (anterior chamber width (ACW)), anterior chamber angle width, iris convexity and iris thickness, were compared between the groups. The associations between angle opening distance and biometric measurements were evaluated with univariate and multivariate regression analyses. RESULTS: There were no differences in age, axial length, anterior chamber angle measurements, pupil diameter and iris convexity between Chinese and Caucasians in both open-angle and narrow-angle groups. However, the ACD and ACW were smaller and the iris was thicker in Chinese. In the multivariate analysis, the ACD was the most influential biometric parameter for angle opening distance in both Chinese and Caucasians. After adjusting the effects of axial length, age and sex, ACD and ACW were significantly smaller in Chinese. CONCLUSIONS: Chinese eyes had smaller ACD, smaller ACW and greater iris thickness than Caucasians. ACD was the most influential parameter in determining the angle width in both ethnic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Real-space grids are a powerful alternative for the simulation of electronic systems. One of the main advantages of the approach is the flexibility and simplicity of working directly in real space where the different fields are discretized on a grid, combined with competitive numerical performance and great potential for parallelization. These properties constitute a great advantage at the time of implementing and testing new physical models. Based on our experience with the Octopus code, in this article we discuss how the real-space approach has allowed for the recent development of new ideas for the simulation of electronic systems. Among these applications are approaches to calculate response properties, modeling of photoemission, optimal control of quantum systems, simulation of plasmonic systems, and the exact solution of the Schrödinger equation for low-dimensionality systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid blue- and redshifted excursions (RBEs and RREs) are likely to be the on-disk counterparts of Type II spicules. Recently, heating signatures from RBEs/RREs have been detected in IRIS slit-jaw images dominated by transition region (TR) lines around network patches. Additionally, signatures of Type II spicules have been observed in Atmospheric Imaging Assembly (AIA) diagnostics. The full-disk, ever-present nature of the AIA diagnostics should provide us with sufficient statistics to directly determine how important RBEs and RREs are to the heating of the TR and corona. We find, with high statistical significance, that at least 11% of the low coronal brightenings detected in a quiet-Sun region in He ii 304 Å can be attributed to either RBEs or RREs as observed in Hα, and a 6% match of Fe IX 171 Å detected events to RBEs or RREs with very similar statistics for both types of Hα features. We took a statistical approach that allows for noisy detections in the coronal channels and provides us with a lower, but statistical significant, bound. Further, we consider matches based on overlapping features in both time and space, and find strong visual indications of further correspondence between coronal events and co-evolving but non-overlapping, RBEs and RREs.