Immunological determination of the pharmaceutical diclofenac in environmental and biological samples


Autoria(s): Knopp, Dietmar; Deng, Anping; Letzel, Marion; Taggart, Mark; Himmelsbach, Markus; Zhu, Qing Zhi; Peröbner, Iris; Kudlak, Blazej; Frey, Siegfried; Sengl, Manfred; Buchberger, Wolfgang; Hutchinson, Clyde; Cunningham, Andrew; Pain, Debbie; Cuthbert, Richard; Raab, Andrea; Meharg, Andrew; Swan, Gerry; Jhala, Yadvendradev; Prakash, Vibhu; Rahmani, Asad; Quevedo, Miguel; Niessner, Reinhard
Data(s)

2007

Resumo

<p>A highly sensitive and specific competitive ELISA on 96-microwell plates was developed for the analysis of the nonsteroidal anti-inflammatory drug diclofenac. Within the water cycle in Europe, this is one of the most frequently detected pharmaceutically active compounds. The LOD at a signal-tonoise ratio (S/N) of 3, and the IC <sub>50</sub>, were found to be 6 ng/L and 60 ng/L respectively in tap water. In a comparative study using ELISA and GC-MS, diclofenac levels in wastewater from 21 sewage treatment plants were determined and a good correlation between these methods was found (ELISA vs. GCMS: r = 0.70, slope = 0,90, intercept = 0.37, n = 24). An average degradation rate of -25% can be calculated. Labscale-experiments on the elimination of diclofenac in continuous pilot sewage plants revealed a removal rate of only 5% over a period of 13 weeks. In a further study, the ELISA was applied to a number of extracts of various animal tissues from a range of species, and again a very good relationship between ELISA and LC-ESI/MS data sets was obtained (r = 0.90, p<0.0001; n = 117). The ELISA has proven to be a simple, rapid, reliable and affordable alternative to otherwise costly and advanced techniques for the detection of diclofenac in matrix diverse water samples and tissue extracts after only relatively simple sample preparation. © 2007 American Chemical Society.</p>

Identificador

http://pure.qub.ac.uk/portal/en/publications/immunological-determination-of-the-pharmaceutical-diclofenac-in-environmental-and-biological-samples(8f416771-2912-4c85-af53-edfe3b59c4f1).html

http://www.scopus.com/inward/record.url?scp=36849032179&partnerID=8YFLogxK

Idioma(s)

eng

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Knopp , D , Deng , A , Letzel , M , Taggart , M , Himmelsbach , M , Zhu , Q Z , Peröbner , I , Kudlak , B , Frey , S , Sengl , M , Buchberger , W , Hutchinson , C , Cunningham , A , Pain , D , Cuthbert , R , Raab , A , Meharg , A , Swan , G , Jhala , Y , Prakash , V , Rahmani , A , Quevedo , M & Niessner , R 2007 , Immunological determination of the pharmaceutical diclofenac in environmental and biological samples . in ACS Symposium Series . vol. 966 , ACS Symposium Series , vol. 966 , pp. 203-226 .

Palavras-Chave #/dk/atira/pure/subjectarea/asjc/1600 #Chemistry(all)
Tipo

contributionToPeriodical