95 resultados para electrical power equipments
Resumo:
This paper presents a new method for transmission loss allocation. The method is based on tracing the complex power flow through the network and determining the share of each load on the flow and losses through each line. Transmission losses are taken into consideration during power flow tracing. Unbundling line losses is carried out using an equation, which has a physical basis, and considers the coupling between active and reactive power flows as well as the cross effects of active and reactive power on active and reactive losses. A tracing algorithm which can be considered direct to a good extent, as there is no need for exhaustive search to determine the flow paths as these are determined in a systematic way during the course of tracing. Results of application of the proposed method are also presented.
Resumo:
A new universal power quality manager is proposed. The proposal treats a number of power quality problems simultaneously. The universal manager comprises a combined series and shunt three-phase PWM controlled converters sharing a common DC link. A control scheme based on fuzzy logic is introduced and the general features of the design and operation processes are outlined. The performance of two configurations of the proposed power quality manager are compared in terms of a recently formulated unified power quality index. The validity and integrity of the proposed system is proved through computer simulated experiments
Resumo:
Hardware implementations of arithmetic operators using signed digit arithmetic have lost some of their earlier popularity. However, SD is revisited and used to realise an efficient radix-16 generic multiplier, which has particular potential for low-power implementation. The SD multiplier algorithm reduces the number of partial products to as much as 1/4, and in initial tests reduces the estimated power consumption to only about 50% of that of the Booth multiplier. It is different from other previous high-radix methods in that it employs a novel method to generate its partial products with zero arithmetic logic.
Resumo:
A novel power-efficient systolic array architecture is proposed for full search block matching (FSBM) motion estimation, where the partial distortion elimination algorithm is used to dynamically switch off the computation of eliminated partial candidate blocks. The RTL-level simulation shows that the proposed architecture can reduce the power consumption of the computation part of the algorithm to about 60% of that of the conventional 2D systolic arrays.
Resumo:
Two electrical techniques that are frequently used to characterize radio frequency plasmas are described: current-voltage probes for plasma power input and compensated Langmuir probes for electron energy probability functions and other parameters. The following examples of the use of these techniques, sometimes in conjunction with other diagnostic methods, are presented: plasma source standardization, plasma system comparison, power efficiency, plasma modelling and complex processing plasma mechanisms.
Resumo:
A constrained non-linear, physical model-based, predictive control (NPMPC) strategy is developed for improved plant-wide control of a thermal power plant. The strategy makes use of successive linearisation and recursive state estimation using extended Kalman filtering to obtain a linear state-space model. The linear model and a quadratic programming routine are used to design a constrained long-range predictive controller One special feature is the careful selection of a specific set of plant model parameters for online estimation, to account for time-varying system characteristics resulting from major system disturbances and ageing. These parameters act as nonstationary stochastic states and help to provide sufficient degrees-of-freedom to obtain unbiased estimates of controlled outputs. A 14th order non-linear plant model, simulating the dominant characteristics of a 200 MW oil-fired pou er plant has been used to test the NPMPC algorithm. The control strategy gives impressive simulation results, during large system disturbances and extremely high rate of load changes, right across the operating range. These results compare favourably to those obtained with the state-space GPC method designed under similar conditions.
Resumo:
A graphical method is presented for determining the capability of individual system nodes to accommodate wind power generation. The method is based upon constructing a capability chart for each node at which a wind farm is to be connected. The capability chart defines the domain of allowable power injections at the candidate node, subject to constraints imposed by voltage limits, voltage stability and equipment capability limits being satisfied. The chart is first derived for a two-bus model, before being extended to a multi-node power system. The graphical method is employed to derive the chart for a two-node system, as well as its application to a multi-node power system, considering the IEEE 30-bus test system as a case study. Although the proposed method is derived with the intention of determining the wind farm capacity to be connected at a specific node, it can be used for the analysis of a PQ bus loading as well as generation.
Resumo:
From the instantaneous efficiency plot, it is observed that the conventional 2-stage Doherty power amplifier (DPA) with high upper power dynamic range (>12 dB) suffers from a substantial dip in the middle of the upper power regime, thus reducing the average efficiency. In this study, an envelope-tracking-based DPA is proposed in order to minimise this dip by adjusting the drain bias voltage of the auxiliary amplifier of the DPA proportional to the input power level.
Resumo:
A newly introduced inverse class-E power amplifier (PA) was designed, simulated, fabricated, and characterized. The PA operated at 2.26 GHz and delivered 20.4-dBm output power with peak drain efficiency (DE) of 65% and power gain of 12 dB. Broadband performance was achieved across a 300-Mitz bandwidth with DE of better than 50% and 1-dB output-power flatness. The concept of enhanced injection predistortion with a capability to selectively suppress unwanted sub-frequency components and hence suitable for memory effects minimization is described coupled with a new technique that facilitates an accurate measurement of the phase of the third-order intermodulation (IM3) products. A robust iterative computational algorithm proposed in this paper dispenses with the need for manual tuning of amplitude and phase of the IM3 injected signals as commonly employed in the previous publications. The constructed inverse class-E PA was subjected to a nonconstant envelope 16 quadrature amplitude modulation signal and was linearized using combined lookup table (LUT) and enhanced injection technique from which superior properties from each technique can be simultaneously adopted. The proposed method resulted in 0.7% measured error vector magnitude (in rms) and 34-dB adjacent channel leakage power ratio improvement, which was 10 dB better than that achieved using the LUT predistortion alone.
Resumo:
This paper investigates the performance characteristics of rapeseed methyl ester, EN 14214 biodiesel, when used for electrical generation in compression ignition engines. The work was inspired by the need to replace fossil diesel fuel with a sustainable low carbon alternative while maintaining generator performance, power quality, and compliance with ISO 8528-5. A 50-kVA Perkins diesel engine generator was used to assess the impact of biodiesel with particular regard to gen-set fuel consumption, load acceptance, and associated standards. Tests were performed on the diesel gen-set for islanded and grid-connected modes of operation, hence both steady-state and transient performance were fully explored. Performance comparisons were made with conventional fossil diesel fuel, revealing minimal technical barriers for electrical generation from this sustainable, carbon benign fuel. Recommendations for improved transient performance are proposed and validated through tests.
Resumo:
This paper proposes new direct power control (DPC) strategies for three-phase DC/AC converters with improved dynamic response and steady-state performance. As with an electrical machine, source and converter flux which equal the integration of the respective source and converter voltage are used to define active and reactive power flow. Optimization of the look-up-table used in conventional DPC is outlined first, to improve the power control and reduce the current distortion. Then constant switching frequency DPC is developed where the required converter voltage vector within a fixed half switching period is calculated directly from the active and reactive power errors. Detailed angle compensation due to the finite sampling frequency and the use of integral controller to further improve the power control accuracy, are described. Both simulation and experimental results are used to compare conventional DPC and vector control, and to demonstrate the effectiveness and robustness of the proposed control strategies during active and reactive power steps, and line inductance variations.
Resumo:
A recently introduced power-combining scheme for a Class-E amplifier is, for the first time, experimentally validated in this paper. A small value choke of 2.2 nH was used to substitute for the massive dc-feed inductance required in the classic Class-E circuit. The power-combining amplifier presented, which operates from a 3.2-V dc supply voltage, is shown to be able to deliver a 24-dBm output power and a 9.5-dB gain, with 64% drain efficiency and 57% power-added efficiency at 2.4 GHz. The power amplifier exhibits a 350-MHz bandwidth within which a drain efficiency that is better than 60% and an output power that is higher than 22 dBm were measured. In addition, by adopting three-harmonic termination strategy, excellent second-and third-harmonic suppression levels of 50 and 46 dBc, respectively, were obtained. The complete design cycle from analysis through fabrication to characterization is explained. © 2010 IEEE.