136 resultados para Cochrane Library
Resumo:
Educational gaming in the health sciences: systematic review. Aim. This paper is a report of a review to investigate the use of games to support classroom learning in the health sciences. Background. One aim of education in the health sciences is to enable learners to develop professional competence. Students have a range of learning styles and innovative teaching strategies assist in creating a dynamic learning environment. New attitudes towards experiential learning methods have contributed to the expansion of gaming as a strategy. Data sources. A search for studies published between January 1980 and June 2008 was undertaken, using appropriate search terms. The databases searched were: British Education Index, British Nursing Index, The Cochrane Library, CINAHLPlus, Medline, PubMed, ERIC, PsychInfo and Australian Education Index. Methods. All publications and theses identified through the search were assessed for relevance. Sixteen papers reporting empirical studies or reviews that involved comparison of gaming with didactic methods were included. Results. The limited research available indicates that, while both traditional didactic methods and gaming have been successful in increasing student knowledge, neither method is clearly more helpful to students. The use of games generally enhances student enjoyment and may improve long-term retention of information. Conclusion. While the use of games can be viewed as a viable teaching strategy, care should be exercised in the use of specific games that have not been assessed objectively. Further research on the use of gaming is needed to enable educators to gaming techniques appropriately for the benefit of students and, ultimately, patients.
Resumo:
A fear of neurology and neural sciences (neurophobia) may have clinical consequences. There is therefore a need to formulate an evidence-based approach to neurology education. A comprehensive systematic review of educational interventions in neurology was performed. BEI, Cochrane Library, Dialog Datastar, EBSCO Biomedical, EBSCO Psychology & Behavioral Sciences, EMBASE, ERIC, First Search, MDConsult, Medline, Proquest Medical Library and Web of Knowledge databases were searched for all published studies assessing interventions in neurology education among undergraduate students, junior medical doctors and residents up to and including July 2012. Two independent literature searches were performed for relevant studies, which were then classified for level of evidence using the Centre of Evidence-based Medicine criteria and four levels of Kirkpatrick educational outcomes. One systematic review, 16 randomized controlled trials (RCTs), nine non-randomized cohort/follow-up studies, 33 case series or historically controlled studies and three mechanism-based reasoning studies were identified. Educational interventions showed favourable evaluation or assessment outcomes in 15 of 16 (94%) RCTs. Very few studies measured subsequent clinical behaviour (two studies) and patient outcomes (one study). There is very little high quality evidence of demonstrably effective neurology education. However, RCTs are emerging, albeit without meeting comprehensive educational criteria. An improving evidence base in the quality of neurology education will be important to reduce neurophobia. © 2013 EFNS.
Resumo:
Objective
to systematically identify interventions that midwives could introduce to address post-traumatic stress in women following childbirth.
Methods
a search strategy was developed and relevant papers were identified from databases including Cinahl, Cochrane Library, EMBASE, Maternity and Infant Care, MEDLINE, PsycINFO, and Web of Science. Key search terms used were post-traumatic stress, post partum, intervention, controlled trial and review. Papers eligible for inclusion were primary studies and reviews of research published from 2002–2012, focusing on interventions which could be implemented by midwives for the prevention and/or management of PTSD. For primary studies, RCTs, controlled clinical trials, and cohort studies with a control group were eligible. Eligible reviews were those with a specified search strategy and inclusion/exclusion criteria. Methodological quality was assessed using recognised frameworks.
Findings
six primary studies and eight reviews were eligible for inclusion. The majority of included studies or reviews focused on debriefing and/or counselling interventions; however the results were not consistent due to significant variation in methodological quality and use of dissimilar interventions. Two of the reviews considered the general management of post partum PTSD and one broadly covered anxiety during pregnancy and the post partum, incorporating a section on PTSD. The majority of women reported that the opportunity to discuss their childbirth experience was subjectively beneficial.
Conclusions and implications for practice
no evidence-based midwifery interventions were identified from this systematic review that can be recommended for introduction into practice to address PTSD. It is recommended that future research in this area should incorporate standardised interventions with similar outcome measures to facilitate synthesis of results. Further research on interventions used in non-maternity populations is needed in order to confirm their usefulness in addressing post partum PTSD.
Resumo:
Background: Chronic musculoskeletal pain is highly prevalent, affecting around one in five people across Europe. Osteoarthritis, low back pain, neck pain and other musculoskeletal disorders are leading causes of disability
worldwide and the most common source of chronic pain. Exercise and/or physical activity interventions have the potential to address not only the pain and disability associated with chronic pain but also the increased risk of morbidity and mortality seen in this population. Although exercise and/or physical activity is widely recommended, there is currently a paucity of research that offers an evidence base upon which the development or optimisation of interventions can be based. This systematic review will investigate the components of interventions associated with changes in physical activity levels in adults with chronic musculoskeletal pain.
Methods/Design: This systematic review will be reported in line with the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidance. Randomised and quasi-randomised controlled trials of interventions aimed at increasing physical activity in adults with chronic musculoskeletal pain will be included. Articles will be identified through a comprehensive search of the following databases: CENTRAL in the Cochrane Library, the Cochrane Database of Systematic Reviews (CDSR), MEDLINE, Embase, CINAHL, PsycINFO and AMED. Two review authors will independently screen articles retrieved from the search for eligibility, extract relevant data on methodological issues and code interventions according to the behaviour change technique taxonomy (v1) of 93 hierarchically clustered techniques. As complex healthcare interventions can be modified by a wide variety of factors, data will be summarised statistically when the data are available, are sufficiently similar and are of sufficient quality. A narrative synthesis will be completed if there is insufficient data to permit a formal meta-analysis.
Discussion: This review will be of value to clinicians working in chronic pain services and to researchers involved in designing and evaluating interventions.
Resumo:
The purpose is to study the diagnostic performance of optical coherence tomography (OCT) and alternative diagnostic tests for neovascular age-related macular degeneration (nAMD). Methods employed are as follows:systematic review and meta-analysis; Index test: OCT including time-domain (TD-OCT) and the most recently developed spectral domain (SD-OCT); comparator tests: visual acuity, clinical evaluation (slit lamp), Amsler chart, colour fundus photographs, infra-red reflectance, red-free images/blue reflectance, fundus autofluorescence imaging (FAF), indocyanine green angiography (ICGA), preferential hyperacuity perimetry (PHP), and microperimetry; reference standard: fundus fluorescein angiography. Databases searched included MEDLINE, MEDLINE In Process, EMBASE, Biosis, SCI, the Cochrane Library, DARE, MEDION, and HTA database. Last literature searches: March 2013. Risk of bias assessed using QUADAS-2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic (HSROC) curves. Twenty-two studies (2 abstracts and 20 articles) enrolling 2124 participants were identified, reporting TD-OCT (12 studies), SD-OCT (1 study), ICGA (8 studies), PHP (3 studies), Amsler grid, colour fundus photography and FAF (1 study each). Most studies were considered to have a high risk of bias in the patient selection (55%, 11/20), and flow and timing (40%, 8/20) domains. In a meta-analysis of TD-OCT studies, sensitivity and specificity (95% CI) were 88% (46–98%) and 78% (64–88%), respectively. There was insufficient information to undertake meta-analysis for other tests. TD-OCT is a sensitive test for detecting nAMD, although specificity was only moderate. Data on SD-OCT are sparse. Diagnosis of nAMD should not rely solely on OCT.
Resumo:
Background: This is an update of a review last published in Issue 5, 2010, of The Cochrane Library. Reducing weaning time is desirable in minimizing potential complications from mechanical ventilation. Standardized weaning protocols are purported to reduce time spent on mechanical ventilation. However, evidence supporting their use in clinical practice is inconsistent. Objectives: The first objective of this review was to compare the total duration of mechanical ventilation of critically ill adults who were weaned using protocols versus usual (non-protocolized) practice.The second objective was to ascertain differences between protocolized and non-protocolized weaning in outcomes measuring weaning duration, harm (adverse events) and resource use (intensive care unit (ICU) and hospital length of stay, cost).The third objective was to explore, using subgroup analyses, variations in outcomes by type of ICU, type of protocol and approach to delivering the protocol (professional-led or computer-driven). Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library Issue 1, 2014), MEDLINE (1950 to January 2014), EMBASE (1988 to January 2014), CINAHL (1937 to January 2014), LILACS (1982 to January 2014), ISI Web of Science and ISI Conference Proceedings (1970 to February 2014), and reference lists of articles. We did not apply language restrictions. The original search was performed in January 2010 and updated in January 2014.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-RCTs of protocolized weaning versus non-protocolized weaning from mechanical ventilation in critically ill adults. Data collection and analysis: Two authors independently assessed trial quality and extracted data. We performed a priori subgroup and sensitivity analyses. We contacted study authors for additional information. Main results: We included 17 trials (with 2434 patients) in this updated review. The original review included 11 trials. The total geometric mean duration of mechanical ventilation in the protocolized weaning group was on average reduced by 26% compared with the usual care group (N = 14 trials, 95% confidence interval (CI) 13% to 37%, P = 0.0002). Reductions were most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. Weaning duration was reduced by 70% (N = 8 trials, 95% CI 27% to 88%, P = 0.009); and ICU length of stay by 11% (N = 9 trials, 95% CI 3% to 19%, P = 0.01). There was significant heterogeneity among studies for total duration of mechanical ventilation (I2 = 67%, P < 0.0001) and weaning duration (I2 = 97%, P < 0.00001), which could not be explained by subgroup analyses based on type of unit or type of approach. Authors' conclusions: There is evidence of reduced duration of mechanical ventilation, weaning duration and ICU length of stay with use of standardized weaning protocols. Reductions are most likely to occur in medical, surgical and mixed ICUs, but not in neurosurgical ICUs. However, significant heterogeneity among studies indicates caution in generalizing results. Some study authors suggest that organizational context may influence outcomes, however these factors were not considered in all included studies and could not be evaluated. Future trials should consider an evaluation of the process of intervention delivery to distinguish between intervention and implementation effects. There is an important need for further development and research in the neurosurgical population.
Resumo:
Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.
Resumo:
Topic
To compare the accuracy of optical coherence tomography (OCT) with alternative tests for monitoring neovascular age-related macular degeneration (nAMD) and detecting disease activity among eyes previously treated for this condition.
Clinical RelevanceTraditionally, fundus fluorescein angiography (FFA) has been considered the reference standard to detect nAMD activity, but FFA is costly and invasive. Replacement of FFA by OCT can be justified if there is a substantial agreement between tests.
MethodsSystematic review and meta-analysis. The index test was OCT. The comparator tests were visual acuity, clinical evaluation (slit lamp), Amsler chart, color fundus photographs, infrared reflectance, red-free images and blue reflectance, fundus autofluorescence imaging, indocyanine green angiography (ICGA), preferential hyperacuity perimetry, and microperimetry. We searched the following databases: MEDLINE, MEDLINE In-Process, EMBASE, Biosis, Science Citation Index, the Cochrane Library, Database of Abstracts of Reviews of Effects, MEDION, and the Health Technology Assessment database. The last literature search was conducted in March 2013. We used the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) to assess risk of bias.
ResultsWe included 8 studies involving more than 400 participants. Seven reported the performance of OCT (3 time-domain [TD] OCT, 3 spectral-domain [SD] OCT, 1 both types) and 1 reported the performance of ICGA in the detection of nAMD activity. We did not find studies directly comparing tests in the same population. The pooled sensitivity and specificity of TD OCT and SD OCT for detecting active nAMD was 85% (95% confidence interval [CI], 72%–93%) and 48% (95% CI, 30%–67%), respectively. One study reported ICGA with sensitivity of 75.9% and specificity of 88.0% for the detection of active nAMD. Half of the studies were considered to have a high risk of bias.
ConclusionsThere is substantial disagreement between OCT and FFA findings in detecting active disease in patients with nAMD who are being monitored. Both methods may be needed to monitor patients comprehensively with nAMD.
Resumo:
BACKGROUND: Age-related macular degeneration is the most common cause of sight impairment in the UK. In neovascular age-related macular degeneration (nAMD), vision worsens rapidly (over weeks) due to abnormal blood vessels developing that leak fluid and blood at the macula.
OBJECTIVES: To determine the optimal role of optical coherence tomography (OCT) in diagnosing people newly presenting with suspected nAMD and monitoring those previously diagnosed with the disease.
DATA SOURCES: Databases searched: MEDLINE (1946 to March 2013), MEDLINE In-Process & Other Non-Indexed Citations (March 2013), EMBASE (1988 to March 2013), Biosciences Information Service (1995 to March 2013), Science Citation Index (1995 to March 2013), The Cochrane Library (Issue 2 2013), Database of Abstracts of Reviews of Effects (inception to March 2013), Medion (inception to March 2013), Health Technology Assessment database (inception to March 2013).
REVIEW METHODS: Types of studies: direct/indirect studies reporting diagnostic outcomes.
INDEX TEST: time domain optical coherence tomography (TD-OCT) or spectral domain optical coherence tomography (SD-OCT).
COMPARATORS: clinical evaluation, visual acuity, Amsler grid, colour fundus photographs, infrared reflectance, red-free images/blue reflectance, fundus autofluorescence imaging, indocyanine green angiography, preferential hyperacuity perimetry, microperimetry. Reference standard: fundus fluorescein angiography (FFA). Risk of bias was assessed using quality assessment of diagnostic accuracy studies, version 2. Meta-analysis models were fitted using hierarchical summary receiver operating characteristic curves. A Markov model was developed (65-year-old cohort, nAMD prevalence 70%), with nine strategies for diagnosis and/or monitoring, and cost-utility analysis conducted. NHS and Personal Social Services perspective was adopted. Costs (2011/12 prices) and quality-adjusted life-years (QALYs) were discounted (3.5%). Deterministic and probabilistic sensitivity analyses were performed.
RESULTS: In pooled estimates of diagnostic studies (all TD-OCT), sensitivity and specificity [95% confidence interval (CI)] was 88% (46% to 98%) and 78% (64% to 88%) respectively. For monitoring, the pooled sensitivity and specificity (95% CI) was 85% (72% to 93%) and 48% (30% to 67%) respectively. The FFA for diagnosis and nurse-technician-led monitoring strategy had the lowest cost (£39,769; QALYs 10.473) and dominated all others except FFA for diagnosis and ophthalmologist-led monitoring (£44,649; QALYs 10.575; incremental cost-effectiveness ratio £47,768). The least costly strategy had a 46.4% probability of being cost-effective at £30,000 willingness-to-pay threshold.
LIMITATIONS: Very few studies provided sufficient information for inclusion in meta-analyses. Only a few studies reported other tests; for some tests no studies were identified. The modelling was hampered by a lack of data on the diagnostic accuracy of strategies involving several tests.
CONCLUSIONS: Based on a small body of evidence of variable quality, OCT had high sensitivity and moderate specificity for diagnosis, and relatively high sensitivity but low specificity for monitoring. Strategies involving OCT alone for diagnosis and/or monitoring were unlikely to be cost-effective. Further research is required on (i) the performance of SD-OCT compared with FFA, especially for monitoring but also for diagnosis; (ii) the performance of strategies involving combinations/sequences of tests, for diagnosis and monitoring; (iii) the likelihood of active and inactive nAMD becoming inactive or active respectively; and (iv) assessment of treatment-associated utility weights (e.g. decrements), through a preference-based study.
STUDY REGISTRATION: This study is registered as PROSPERO CRD42012001930.
FUNDING: The National Institute for Health Research Health Technology Assessment programme.
Resumo:
Background
Diabetic macular oedema (DMO) is a thickening of the central retina, or the macula, and is associated with long-term visual loss in people with diabetic retinopathy (DR). Clinically significant macular oedema (CSMO) is the most severe form of DMO. Almost 30 years ago, the Early Treatment Diabetic Retinopathy Study (ETDRS) found that CSMO, diagnosed by means of stereoscopic fundus photography, leads to moderate visual loss in one of four people within three years. It also showed that grid or focal laser photocoagulation to the macula halves this risk. Recently, intravitreal injection of antiangiogenic drugs has also been used to try to improve vision in people with macular oedema due to DR.Optical coherence tomography (OCT) is based on optical reflectivity and is able to image retinal thickness and structure producing cross-sectional and three-dimensional images of the central retina. It is widely used because it provides objective and quantitative assessment of macular oedema, unlike the subjectivity of fundus biomicroscopic assessment which is routinely used by ophthalmologists instead of photography. Optical coherence tomography is also used for quantitative follow-up of the effects of treatment of CSMO.
Objectives
To determine the diagnostic accuracy of OCT for detecting DMO and CSMO, defined according to ETDRS in 1985, in patients referred to ophthalmologists after DR is detected. In the update of this review we also aimed to assess whether OCT might be considered the new reference standard for detecting DMO.
Search methods
We searched the Cochrane Database of Systematic Reviews (CDSR), the Database of Abstracts of Reviews of Effects (DARE), the Health Technology Assessment Database (HTA) and the NHS Economic Evaluation Database (NHSEED) (The Cochrane Library 2013, Issue 5), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to June 2013), EMBASE (January 1950 to June 2013), Web of Science Conference Proceedings Citation Index - Science (CPCI-S) (January 1990 to June 2013), BIOSIS Previews (January 1969 to June 2013), MEDION and the Aggressive Research Intelligence Facility database (ARIF). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 25 June 2013. We checked bibliographies of relevant studies for additional references.
Selection Criteria
We selected studies that assessed the diagnostic accuracy of any OCT model for detecting DMO or CSMO in patients with DR who were referred to eye clinics. Diabetic macular oedema and CSMO were diagnosed by means of fundus biomicroscopy by ophthalmologists or stereophotography by ophthalmologists or other trained personnel.
Data collection and analysis
Three authors independently extracted data on study characteristics and measures of accuracy. We assessed data using random-effects hierarchical sROC meta-analysis models.
Main results
We included 10 studies (830 participants, 1387 eyes), published between 1998 and 2012. Prevalence of CSMO was 19% to 65% (median 50%) in nine studies with CSMO as the target condition. Study quality was often unclear or at high risk of bias for QUADAS 2 items, specifically regarding study population selection and the exclusion of participants with poor quality images. Applicablity was unclear in all studies since professionals referring patients and results of prior testing were not reported. There was a specific 'unit of analysis' issue because both eyes of the majority of participants were included in the analyses as if they were independent.In nine studies providing data on CSMO (759 participants, 1303 eyes), pooled sensitivity was 0.78 (95% confidence interval (CI) 0.72 to 0.83) and specificity was 0.86 (95% CI 0.76 to 0.93). The median central retinal thickness cut-off we selected for data extraction was 250 µm (range 230 µm to 300 µm). Central CSMO was the target condition in all but two studies and thus our results cannot be applied to non-central CSMO.Data from three studies reporting accuracy for detection of DMO (180 participants, 343 eyes) were not pooled. Sensitivities and specificities were about 0.80 in two studies and were both 1.00 in the third study.Since this review was conceived, the role of OCT has changed and has become a key ingredient of decision-making at all levels of ophthalmic care in this field. Moreover, disagreements between OCT and fundus examination are informative, especially false positives which are referred to as subclinical DMO and are at higher risk of developing clinical CSMO.
Authors' conclusions
Using retinal thickness thresholds lower than 300 µm and ophthalmologist's fundus assessment as reference standard, central retinal thickness measured with OCT was not sufficiently accurate to diagnose the central type of CSMO in patients with DR referred to retina clinics. However, at least OCT false positives are generally cases of subclinical DMO that cannot be detected clinically but still suffer from increased risk of disease progression. Therefore, the increasing availability of OCT devices, together with their precision and the ability to inform on retinal layer structure, now make OCT widely recognised as the new reference standard for assessment of DMO, even in some screening settings. Thus, this review will not be updated further.
Resumo:
Background: Skeletal muscle wasting and weakness are significant complications of critical illness, associated with the degree of illness severity and periods of reduced mobility during mechanical ventilation. They contribute to the profound physical and functional deficits observed in survivors. These impairments may persist for many years following discharge from the intensive care unit (ICU) and may markedly influence health-related quality of life. Rehabilitation is a key strategy in the recovery of patients following critical illness. Exercise based interventions are aimed at targeting this muscle wasting and weakness. Physical rehabilitation delivered during ICU admission has been systematically evaluated and shown to be beneficial. However its effectiveness when initiated after ICU discharge has yet to be established. Objectives: To assess the effectiveness of exercise rehabilitation programmes, initiated after ICU discharge, on functional exercise capacity and health-related quality of life in adult ICU survivors who have been mechanically ventilated for more than 24 hours. Search methods:We searched the following databases: the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), OvidSP MEDLINE, Ovid SP EMBASE, and CINAHL via EBSCO host to 15th May 2014. We used a specific search strategy for each database. This included synonyms for ICU and critical illness, exercise training and rehabilitation. We searched the reference lists of included studies and contacted primary authors to obtain further information regarding potentially eligible studies. We also searched major clinical trials registries (Clinical Trials and Current Controlled Trials) and the personal libraries of the review authors. We applied no language or publication restriction. We reran the search in February 2015. We will deal with any studies of interest when we update the review. Selection criteria:We included randomized controlled trials (RCTs), quasi-RCTs, and controlled clinical trials (CCTs) that compared an exercise interventioninitiated after ICU discharge to any other intervention or a control or ‘usual care’ programme in adult (≥18years) survivors ofcritical illness. Data collection and analysis:We used standard methodological procedures expected by The Cochrane Collaboration. Main results:We included six trials (483 adult ICU participants). Exercise-based interventions were delivered on the ward in two studies; both onthe ward and in the community in one study; and in the community in three studies. The duration of the intervention varied according to the length of stay in hospital following ICU discharge (up to a fixed duration of 12 weeks).Risk of bias was variable for all domains across all trials. High risk of bias was evident in all studies for performance bias, although blinding of participants and personnel in therapeutic rehabilitation trials can be pragmatically challenging. Low risk of bias was at least 50% for all other domains across all trials, although high risk of bias was present in one study for random sequence generation (selection bias), incomplete outcome data (attrition bias) and other sources. Risk of bias was unclear for remaining studies across the domains.All six studies measured effect on the primary outcome of functional exercise capacity, although there was wide variability in natureof intervention, outcome measures and associated metrics, and data reporting. Overall quality of the evidence was very low. Only two studies using the same outcome measure for functional exercise capacity, had the potential for pooling of data and assessment of heterogeneity. On statistical advice, this was considered inappropriate to perform this analysis and study findings were therefore qualitatively described. Individually, three studies reported positive results in favour of the intervention. A small benefit (versus. control)was evident in anaerobic threshold in one study (mean difference, MD (95% confidence interval, CI), 1.8 mlO2/kg/min (0.4 to 3.2),P value = 0.02), although this effect was short-term, and in a second study, both incremental (MD 4.7 (95% CI 1.69 to 7.75) Watts, P value = 0.003) and endurance (MD 4.12 (95% CI 0.68 to 7.56) minutes, P value = 0.021) exercise testing demonstrated improvement.Finally self-reported physical function increased significantly following a rehabilitation manual (P value = 0.006). Remaining studies found no effect of the intervention.Similar variability in with regard findings for the primary outcome of health-related quality of life were also evident. Only two studies evaluated this outcome. Following statistical advice, these data again were considered inappropriate for pooling to determine overall effect and assessment of heterogeneity. Qualitative description of findings was therefore undertaken. Individually, neither study reported differences between intervention and control groups for health-related quality of life as a result of the intervention. Overall quality of the evidence was very low.Mortality was reported by all studies, ranging from 0% to 18.8%. Only one non-mortality adverse event was reported across all patients in all studies (a minor musculoskeletal injury). Withdrawals, reported in four studies, ranged from 0% to 26.5% in control groups,and 8.2% to 27.6% in intervention groups. Loss to follow-up, reported in all studies, ranged from 0% to 14% in control groups, and 0% to 12.5% in intervention groups. Authors’ conclusions:We are unable, at this time, to determine an overall effect on functional exercise capacity, or health-related quality of life, of an exercise based intervention initiated after ICU discharge in survivors of critical illness. Meta-analysis of findings was not appropriate. This was due to insufficient study number and data. Individual study findings were inconsistent. Some studies reported a beneficial effect of the intervention on functional exercise capacity, and others not. No effect was reported on health-related quality of life. Methodological rigour was lacking across a number of domains influencing quality of the evidence. There was also wide variability in the characteristics of interventions, outcome measures and associated metrics, and data reporting.If further trials are identified, we may be able to determine the effect of exercise-based interventions following ICU discharge, on functional exercise capacity and health-related quality of life in survivors of critical illness.
Resumo:
BACKGROUND/AIMS: The purpose of this systematic review was to identify the frequency and type of patient-reported outcome measures (PROMs) used in recent randomised controlled trials (RCTs) for age-related macular degeneration (AMD).
METHODS: The authors conducted a systematic search between January 2010 and November 2013 in MEDLINE, EMBASE, Scopus, Cochrane Library (Central) and the clinical trials registries (http://www.controlled-trials.com and http://www.ClinicalTrials.gov) according to defined inclusion criteria (RCTs on AMD in English). Two independent reviewers evaluated studies for inclusion. One reviewer extracted data of included studies, and a second masked reviewer assessed 10% to confirm accuracy in data collection. Reference lists of included papers and appendices of relevant Cochrane systematic reviews were scanned to identify other relevant RCTs. Information collected on extracted outcomes was analysed using descriptive statistics.
RESULTS: Literature and registry search yielded 3816 abstracts of journal articles and 493 records from trial registries. A total of 177 RCTs were deemed to have met inclusion criteria. Of the 858 outcomes reported, 38 outcomes were identified as PROMs (4.4%). Of the 177 RCTs examined, PROMs were used in 25 trials (14.1%). The National Eye Institute Visual Function Questionnaire-25 was the most frequently used PROM instrument (64% of RCTs with PROMs included).
CONCLUSIONS: This review highlights that a small proportion of AMD RCTs included PROMs as outcome measures and that there was a variety in the instruments used.
Resumo:
BACKGROUND: The prevalence of obesity is increasing globally and is associated with chronic kidney disease and premature mortality. However, the impact of recipient obesity on kidney transplant outcomes remains unclear. This study aimed to investigate the association between recipient obesity and mortality, death-censored graft loss and delayed graft function (DGF) following kidney transplantation.
METHODS: A systematic review and meta-analysis was conducted using Medline, Embase and the Cochrane Library. Observational studies or randomized controlled trials investigating the association between recipient obesity at transplantation and mortality, death-censored graft loss and DGF were included. Obesity was defined as a body mass index (BMI) of ≥30 kg/m(2). Obese recipients were compared with those with a normal BMI (18.5-24.9 kg/m(2)). Pooled estimates of hazard ratios (HRs) for patient mortality or death-censored graft loss and odds ratios (ORs) for DGF were calculated.
RESULTS: Seventeen studies including 138 081 patients were analysed. After adjustment, there was no significant difference in mortality risk in obese recipients [HR = 1.24, 95% confidence interval (CI) = 0.90-1.70, studies = 5, n = 83 416]. However, obesity was associated with an increased risk of death-censored graft loss (HR = 1.06, 95% CI = 1.01-1.12, studies = 5, n = 83 416) and an increased likelihood of DGF (OR = 1.68, 95% CI = 1.39-2.03, studies = 4, n = 28 847).
CONCLUSIONS: Despite having a much higher likelihood of DGF, obese transplant recipients have only a slightly increased risk of graft loss and experience similar survival to recipients with normal BMI.
Resumo:
Objective: This review intends to examine current research surrounding economic assessment in the delivery of dental care. Economic evaluation is an acknowledged method of analysing dental care systems by means of efficiency, effectiveness, efficacy and availability. Though this is a widely used method in medicine, it is underappreciated in dentistry. As the delivery of health care changes there has been recent demand by the public, the profession, and those funding dental treatment to investigate current practices regarding programs themselves and resource allocation.
Methods: A meta-analysis was conducted regarding health economics. The initial search was carried out using Pubmed, Google Scholar, Science Direct, and The Cochrane Library with search terms “health AND economics AND dentistry”. A secondary search was conducted with the terms “heath care AND dentistry AND”. The third part of the entry was changed to address the aims and included the following terms: “cost benefit analysis”, “efficiency criteria”, “supply & demand”, “cost-effectiveness”, “cost minimisation”, “cost utility”, “resource allocation”, “QALY”, and “delivery and economics”. Limits were applied to all searches to only include papers published in English within the last eight years.
Results: Preliminary results demonstrated a limited number of economic evaluations conducted in dentistry. Those that were carried out were mainly confined to the United Kingdom. Furthermore analysis was mainly restricted to restorative dentistry, followed by orthodontics, and maxillofacial surgery, thereby demonstrating a need for investigation in all fields of dentistry.
Conclusion: Health economics has been overlooked in the past regarding delivery of dental care and resource allocation. Economic appraisal is a crucial part of generating an effective and efficient dental care system. It is becoming increasingly evident that there is a need for economic evaluation in all dental fields.
Resumo:
Aim: To evaluate and summarize the current evidence on the effectiveness of complementary and alternative medicine for the management of low back pain and/or pelvic pain in pregnancy.
Background: International research demonstrates that 25-30% of women use complementary and alternative medicine to manage low back and pelvic pain in pregnancy without robust evidence demonstrating its effectiveness.
Design: A systematic review of randomized controlled trials to determine the effectiveness of complementary and alternative medicine for low back and/or pelvic pain in pregnancy.
Data Sources: Cochrane library (1898-2013), PubMed (1996-2013), MEDLINE (1946-2013), AMED (1985-2013), Embase (1974-2013), Cinahl (1937-2013), Index to Thesis (1716-2013) and Ethos (1914-2013).
Review Methods: Selected studies were written in English, randomized controlled trials, a group 1 or 2 therapy and reported pain reduction as an outcome measure. Study quality was reviewed using Risk of Bias and evidence strength the Cochrane Grading of Recommendations and Development Evaluation Tool.
Results: Eight studies were selected for full review. Two acupuncture studies with low risk of bias showed both clinically important changes and statistically significant results. There was evidence of effectiveness for osteopathy and chiropractic. However, osteopathy and chiropractic studies scored high for risk of bias. Strength of the evidence across studies was very low.
Conclusion: There is limited evidence supporting the use of general CAM for managing pregnancy-related low back and/or pelvic pain. However, the restricted availability of high-quality studies, combined with the very low evidence strength, makes it impossible to make evidence-based recommendations for practice.