42 resultados para Uninterruptable Power Supply


Relevância:

30.00% 30.00%

Publicador:

Resumo:

An analysis of a modified series-L/parallel-tuned Class-E power amplifier is presented, which includes the effects that a shunt capacitance placed across the switching device will have on Class-E behaviour. In the original series L/parallel-tuned topology in which the output transistor capacitance is not inherently included in the circuit, zero-current switching (ZCS) and zero-current derivative switching (ZCDS) conditions should be applied to obtain optimum Class-E operation. On the other hand, when the output transistor capacitance is incorporated in the circuit, i.e. in the modified series-L/parallel-tuned topology, the ZCS and ZCDS would not give optimum operation and therefore zero-voltage-switching (ZVS) and zero-voltage-derivative switching (ZVDS) conditions should be applied instead. In the modified series-L/parallel-tuned Class-E configuration, the output-device inductance and the output-device output capacitance, both of which can significantly affect the amplifier's performance at microwave frequencies, furnish part, if not all, of the series inductance L and the shunt capacitance COUT, respectively. Further, when compared with the classic shunt-C/series-tuned topology, the proposed Class-E configuration offers some advantages in terms of 44% higher maximum operating frequency (fMAX) and 4% higher power-output capability (PMAX). As in the classic topology, the fMAX of the proposed amplifier circuit is reached when the output-device output capacitance furnishes all of the capacitance COUT, for a given combination of frequency, output power and DC supply voltage. It is also shown that numerical simulations agree well with theoretical predictions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Closed-form design equations for the operation of a class-E amplifier for zero switch voltage slope and arbitrary duty cycle are derived. This approach allows an additional degree of freedom in the design of class-E amplifiers which are normally designed for 50 duty ratio. The analysis developed permits the selection of non-unique solutions where amplifier efficiency is theoretically 100 but power output capability is less than that the 50 duty ratio case would permit. To facilitate comparison between 50 (optimal) and non-50 (suboptimal) duty ratio cases, each important amplifier parameter is normalised to its corresponding optimum operation value. It is shown that by choosing a non-50 suboptimal solution, the operating frequency of a class-E amplifier can be extended. In addition, it is shown that by operating the amplifier in the suboptimal regime, other amplifier parameters, for example, transistor output capacitance or peak switch voltage, can be included along with the standard specification criteria of output power, DC supply voltage and operating frequency as additional input design specifications. Suboptimum class-E operation may have potential advantages for monolithic microwave integrated circuit realisation as lower inductance values (lower series resistance, higher self-resonance frequency, less area) may be required when compared with the results obtained for optimal class-E amplifier synthesis. The theoretical analysis conducted here was verified by harmonic balance simulation, with excellent agreement between both methods. © The Institution of Engineering and Technology 2007.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The design procedure, fabrication and measurement of a Class-E power amplifier with excellent second- and third-harmonic suppression levels are presented. A simplified design technique offering compact physical layout is proposed. With a 1.2 mm gate-width GaAs MESFET as a switching device, the amplifier is capable of delivering 19.2 dBm output power at 2.41 GHz, achieves peak PAE of 60% and drain efficiency of 69%, and exhibits 9 dB power gain when operated from a 3 V DC supply voltage. When compared to the classical Class-E two-harmonic termination amplifier, the Class-E amplifier employing three-harmonic terminations has more than 10% higher drain efficiency and 23 dB better third-harmonic suppression level. Experimental results are presented and good agreement with simulation is obtained. Further, to verify the practical implementation in communication systems, the Bluetooth-standard GFSK modulated signal is applied to both two- and three-harmonic amplifiers. The measured RMS FSK deviation error and RMS magnitude error were, for the three-harmonic case, 1.01 kHz and 0.122%, respectively, and, for the two-harmonic case, 1.09 kHz and 0.133%. © 2007 The Institution of Engineering and Technology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A recently introduced power-combining scheme for a Class-E amplifier is, for the first time, experimentally validated in this paper. A small value choke of 2.2 nH was used to substitute for the massive dc-feed inductance required in the classic Class-E circuit. The power-combining amplifier presented, which operates from a 3.2-V dc supply voltage, is shown to be able to deliver a 24-dBm output power and a 9.5-dB gain, with 64% drain efficiency and 57% power-added efficiency at 2.4 GHz. The power amplifier exhibits a 350-MHz bandwidth within which a drain efficiency that is better than 60% and an output power that is higher than 22 dBm were measured. In addition, by adopting three-harmonic termination strategy, excellent second-and third-harmonic suppression levels of 50 and 46 dBc, respectively, were obtained. The complete design cycle from analysis through fabrication to characterization is explained. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wind power generation differs from conventional thermal generation due to the stochastic nature of wind. Thus wind power forecasting plays a key role in dealing with the challenges of balancing supply and demand in any electricity system, given the uncertainty associated with the wind farm power output. Accurate wind power forecasting reduces the need for additional balancing energy and reserve power to integrate wind power. Wind power forecasting tools enable better dispatch, scheduling and unit commitment of thermal generators, hydro plant and energy storage plant and more competitive market trading as wind power ramps up and down on the grid. This paper presents an in-depth review of the current methods and advances in wind power forecasting and prediction. Firstly, numerical wind prediction methods from global to local scales, ensemble forecasting, upscaling and downscaling processes are discussed. Next the statistical and machine learning approach methods are detailed. Then the techniques used for benchmarking and uncertainty analysis of forecasts are overviewed, and the performance of various approaches over different forecast time horizons is examined. Finally, current research activities, challenges and potential future developments are appraised. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dwindling fossil fuel resources and pressures to reduce greenhouse gas (GHG) emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is that supply instantaneously meets demand and that robust operating standards are maintained to ensure a consistent supply of high quality electricity to end-users. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management (DSM) with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating (EWH) has been studied previously, particularly at the domestic level to provide load control, peak shave and to benefit end-users financially with lower bills, particularly in vertically integrated monopolies. In this paper, a continuous Direct Load Control (DLC) EWH algorithm is applied in a liberalized market environment using actual historical electricity system and market data to examine the potential energy savings, cost reductions and electricity system operational improvements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents holistic design of a novel four-way differential power-combining transformer for use in millimeter-wave power-amplifier (PA). The combiner with an inner radius of 25 µm exhibits a record low insertion loss of 1.25 dB at 83.5 GHz. It is designed to simultaneously act as a balanced-to-unbalanced converter, removing the need for additional BALUNs typically required in differential circuits. A complete circuit comprised of a power splitter, two-stage differential cascode PA array, a power combiner as well as input and output matching elements was designed and realized in SiGe technology with f/f 170/250 GHz. Measured small-signal gain of at least 16.8 dB was obtained from 76.4 to 85.3 GHz with a peak 19.5 dB at 83 GHz. The prototype delivered 12.5 dBm output referred 1 dB compression point and 14 dBm saturated output power when operated from a 3.2 V dc supply voltage at 78 GHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental assessments of the modified power-combining Class-E amplifier are described. The technique used to combine the output of individual power amplifiers (PAs) into an unbalanced load without the need for bulky transformers permits the use of small RF chokes useful for the deployment in the EER transmitter. The modified output load network of the PA results in excellent 50 dBc and 46 dBc second and third-harmonic suppressions, dispensing the need for additional lossy filtering block. Operating from a 3.2 V dc supply voltage, the PA exhibits 64% drain efficiency at 24 dBm output power. Over a wide bandwidth of 350 MHz, drain efficiency of better than 60% at output power higher than 22 dBm were achieved. © 2010 IEICE Institute of Electronics Informati.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The operation of supply chains (SCs) has for many years been focused on efficiency, leanness and responsiveness. This has resulted in reduced slack in operations, compressed cycle times, increased productivity and minimised inventory levels along the SC. Combined with tight tolerance settings for the realisation of logistics and production processes, this has led to SC performances that are frequently not robust. SCs are becoming increasingly vulnerable to disturbances, which can decrease the competitive power of the entire chain in the market. Moreover, in the case of food SCs non-robust performances may ultimately result in empty shelves in grocery stores and supermarkets.
The overall objective of this research is to contribute to Supply Chain Management (SCM) theory by developing a structured approach to assess SC vulnerability, so that robust performances of food SCs can be assured. We also aim to help companies in the food industry to evaluate their current state of vulnerability, and to improve their performance robustness through a better understanding of vulnerability issues. The following research questions (RQs) stem from these objectives:
RQ1: What are the main research challenges related to (food) SC robustness?
RQ2: What are the main elements that have to be considered in the design of robust SCs and what are the relationships between these elements?
RQ3: What is the relationship between the contextual factors of food SCs and the use of disturbance management principles?
RQ4: How to systematically assess the impact of disturbances in (food) SC processes on the robustness of (food) SC performances?
To answer these RQs we used different methodologies, both qualitative and quantitative. For each question, we conducted a literature survey to identify gaps in existing research and define the state of the art of knowledge on the related topics. For the second and third RQ, we conducted both exploration and testing on selected case studies. Finally, to obtain more detailed answers to the fourth question, we used simulation modelling and scenario analysis for vulnerability assessment.
Main findings are summarised as follows.
Based on an extensive literature review, we answered RQ1. The main research challenges were related to the need to define SC robustness more precisely, to identify and classify disturbances and their causes in the context of the specific characteristics of SCs and to make a systematic overview of (re)design strategies that may improve SC robustness. Also, we found that it is useful to be able to discriminate between varying degrees of SC vulnerability and to find a measure that quantifies the extent to which a company or SC shows robust performances when exposed to disturbances.
To address RQ2, we define SC robustness as the degree to which a SC shows an acceptable performance in (each of) its Key Performance Indicators (KPIs) during and after an unexpected event that caused a disturbance in one or more logistics processes. Based on the SCM literature we identified the main elements needed to achieve robust performances and structured them together to form a conceptual framework for the design of robust SCs. We then explained the logic of the framework and elaborate on each of its main elements: the SC scenario, SC disturbances, SC performance, sources of food SC vulnerability, and redesign principles and strategies.
Based on three case studies, we answered RQ3. Our major findings show that the contextual factors have a consistent relationship to Disturbance Management Principles (DMPs). The product and SC environment characteristics are contextual factors that are hard to change and these characteristics initiate the use of specific DMPs as well as constrain the use of potential response actions. The process and the SC network characteristics are contextual factors that are easier to change, and they are affected by the use of the DMPs. We also found a notable relationship between the type of DMP likely to be used and the particular combination of contextual factors present in the observed SC.
To address RQ4, we presented a new method for vulnerability assessments, the VULA method. The VULA method helps to identify how much a company is underperforming on a specific Key Performance Indicator (KPI) in the case of a disturbance, how often this would happen and how long it would last. It ultimately informs the decision maker about whether process redesign is needed and what kind of redesign strategies should be used in order to increase the SC’s robustness. The VULA method is demonstrated in the context of a meat SC using discrete-event simulation. The case findings show that performance robustness can be assessed for any KPI using the VULA method.
To sum-up the project, all findings were incorporated within an integrated framework for designing robust SCs. The integrated framework consists of the following steps: 1) Description of the SC scenario and identification of its specific contextual factors; 2) Identification of disturbances that may affect KPIs; 3) Definition of the relevant KPIs and identification of the main disturbances through assessment of the SC performance robustness (i.e. application of the VULA method); 4) Identification of the sources of vulnerability that may (strongly) affect the robustness of performances and eventually increase the vulnerability of the SC; 5) Identification of appropriate preventive or disturbance impact reductive redesign strategies; 6) Alteration of SC scenario elements as required by the selected redesign strategies and repeat VULA method for KPIs, as defined in Step 3.
Contributions of this research are listed as follows. First, we have identified emerging research areas - SC robustness, and its counterpart, vulnerability. Second, we have developed a definition of SC robustness, operationalized it, and identified and structured the relevant elements for the design of robust SCs in the form of a research framework. With this research framework, we contribute to a better understanding of the concepts of vulnerability and robustness and related issues in food SCs. Third, we identified the relationship between contextual factors of food SCs and specific DMPs used to maintain robust SC performances: characteristics of the product and the SC environment influence the selection and use of DMPs; processes and SC networks are influenced by DMPs. Fourth, we developed specific metrics for vulnerability assessments, which serve as a basis of a VULA method. The VULA method investigates different measures of the variability of both the duration of impacts from disturbances and the fluctuations in their magnitude.
With this project, we also hope to have delivered practical insights into food SC vulnerability. First, the integrated framework for the design of robust SCs can be used to guide food companies in successful disturbance management. Second, empirical findings from case studies lead to the identification of changeable characteristics of SCs that can serve as a basis for assessing where to focus efforts to manage disturbances. Third, the VULA method can help top management to get more reliable information about the “health” of the company.
The two most important research opportunities are: First, there is a need to extend and validate our findings related to the research framework and contextual factors through further case studies related to other types of (food) products and other types of SCs. Second, there is a need to further develop and test the VULA method, e.g.: to use other indicators and statistical measures for disturbance detection and SC improvement; to define the most appropriate KPI to represent the robustness of a complete SC. We hope this thesis invites other researchers to pick up these challenges and help us further improve the robustness of (food) SCs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The global increase in the penetration of renewable energy is pushing electrical power systems into uncharted territory, especially in terms of transient and dynamic stability. In particular, the greater penetration of wind generation in European power networks is, at times, displacing a significant capacity of conventional synchronous generation with fixed-speed induction generation and now more commonly, doubly-fed induction generators. The impact of such changes in the generation mix requires careful monitoring to assess the impact on transient and dynamic stability. This paper presents a measurement based method for the early detection of power system oscillations, with attention to mode damping, in order to raise alarms and develop strategies to actively improve power system dynamic stability and security. A method is developed based on wavelet transform and support vector data description (SVDD) to detect oscillation modes in wind farm output power, which may excite dynamic instabilities in the wider system. The wavelet transform is used as a filter to identify oscillations in different frequency bands, while SVDD is used to extract dominant features from different scales and generate an assessment boundary according to the extracted features. Poorly damped oscillations of a large magnitude or that are resonant can be alarmed to the system operator, to reduce the risk of system instability. Method evaluation is exemplified used real data from a chosen wind farm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Frequency stability has not necessarily been a major problem for the majority of power systems in the past. However, for economic and environmental reasons, power systems are now operated closer to stability limits to maximise the use of the existing networks. Therefore, introduction of new, more efficient and renewable generation technologies, and their effect on the power system must be fully understood if a reliable and secure electricity supply is to be maintained. Using the Northern Ireland, and interconnected Republic of Ireland electricity networks as a case study, this paper addresses some of the issues regarding integration and modelling of combined cycle gas turbines (CCGT), and wind turbine generator (WTG) technology on a small islanded power system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines power quality benchmarks in the electricity supply industry (ESI) and impact of standards for the reduction of voltage dip incidents. The paper considers adherence to particular standards and is supported by several case studies from incidents where voltage dips have been detected and assessed by the power systems division of Scottish Power and where improvements have been implemented to help militate against subsequent incidents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design of a novel 8-way power-combining transformer for use in mm-wave power amplifier (PA). The combiner exhibits a record low insertion loss of 1.25 dB at 83.5 GHz. A complete circuit comprised of a power splitter, two-stage cascode PA array, a power combiner and input/output matching elements was designed and realized in SiGe technology. Measured gain of at least 16.8 dB was obtained from 76.4 GHz to 85.3 GHz with a peak 19.5 dB at 83 GHz. The prototype delivered 12.5 dBm OP and 14 dBm saturated output power when operated from a 3.2 V DC supply voltage at 78 GHz. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and implementation of a differential 4-way power-combining amplifier operating at E-band. The proposed 4-way power combiner (4WPC) facilitates short interconnects to the PA cells, thereby resulting in reduced loss. Simple C-L-C and L-C networks are deployed in order to compensate inductive loading due to the routing lines that would otherwise introduce mismatch and subsequently increase overall loss. Realized in SiGe technology, the PA prototype delivered 13.2 dBm output-referred 1-dB compression point and 14.3 dBm saturated output power when operated from a single 3.3 V DC supply at 75 GHz.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we present a novel discrete cosine transform (DCT) architecture that allows aggressive voltage scaling for low-power dissipation, even under process parameter variations with minimal overhead as opposed to existing techniques. Under a scaled supply voltage and/or variations in process parameters, any possible delay errors appear only from the long paths that are designed to be less contributive to output quality. The proposed architecture allows a graceful degradation in the peak SNR (PSNR) under aggressive voltage scaling as well as extreme process variations. Results show that even under large process variations (±3σ around mean threshold voltage) and aggressive supply voltage scaling (at 0.88 V, while the nominal voltage is 1.2 V for a 90-nm technology), there is a gradual degradation of image quality with considerable power savings (71% at PSNR of 23.4 dB) for the proposed architecture, when compared to existing implementations in a 90-nm process technology. © 2006 IEEE.