15 resultados para three-dimensional atom probe

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we probe the stability of a z = 3 three-dimensional Lifshitz black hole by using scalar and spinorial perturbations. We found an analytical expression for the quasinormal frequencies of the scalar probe field, which perfectly agree with the behavior of the quasinormal modes obtained numerically. The results for the numerical analysis of the spinorial perturbations reinforce the conclusion of the scalar analysis, i.e., the model is stable under scalar and spinor perturbations. As an application we found the area spectrum of the Lifshitz black hole, which turns out to be equally spaced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider a solution of three dimensional New Massive Gravity with a negative cosmological constant and use the AdS/CTF correspondence to inquire about the equivalent two dimensional model at the boundary. We conclude that there should be a close relation of the theory with the Korteweg-de Vries equation. (C) 2012 Elsevier B.V..All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fractures of the mandibular angle deserve particular attention because they represent the highest percentage of mandibular fractures and have the highest postsurgical complication rate, making them the most challenging and unpredictable mandibular fractures to treat. Despite the evolution in the treatment of maxillofacial trauma and fixation methods, no single treatment modality has been revealed to be ideal for mandibular angle fractures. Several methods of internal fixation have been studied with great variation in complications rates, especially postoperative infections. Recently, new studies have shown reduction of postsurgical complications rates using three-dimensional plates to treat mandibular angle fractures. Nevertheless, only few surgeons have used this type of plate for the treatment of mandibular angle fractures. The aim of this clinical report was to describe a case of a patient with a mandibular angle fracture treated by an intraoral approach and a three-dimensional rectangular grid miniplate with 4 holes, which was stabilized with monocortical screws. The authors show a follow-up of 8 months, without infection and with occlusal stability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: The Head and Neck Squamous Cell Carcinoma (HNSCC) ranks sixth worldwide. The mechanisms of growth, invasion and metastasis of this pathology are extensively studied and generally related to specific variations in signaling pathways like the PI3K-Akt; however most of these competent studies have been performed bidimensionally, which may hide important questions. This study sought to analyze the influence of the microenvironment upon the behavior of HNSCC. Study Design: The status of pAkt, NF-kappa B and Cyclin D1 proteins was accessed through immunofluorescence and western blot methods in HNSCC cell lines originating from tongue, pharynx and metastatic lymph node when submitted to a three-dimensional culture model utilizing a matrix system. A bidimensional culture model (monolayer) was used as control. Results: The HNSCC cell lines cultured three-dimensionally exhibited a growth pattern characterized by small isolated islands, different from the control group. When the three-dimensional model was applied, two of the studied cell lines showed the same expression pattern as the bidimensional model regarding nuclear or cytoplasmatic localization, as well as reduction of all protein levels; however, the cell line originated from tongue, which specially has the epidermal growth factor receptor constitutively activated, demonstrated nuclear translocation of pAkt and also an increase in the levels of Cyclin D1. Conclusions: The results suggest the influence of the microenvironment upon the behavior of HNSCC cells due to the changed expression of proteins related to tumor growth and cellular invasion. Furthermore, intrinsically genetic conditions also played important roles over the cells, despite the culture model employed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives-The purpose of this study was to predict perinatal outcomes using fetal total lung volumes assessed by 3-dimensional ultrasonography (3DUS) in primary pleural effusion. Methods-Between July 2005 and July 2010, total lung volumes were prospectively estimated in fetuses with primary pleural effusion by 3DUS using virtual organ computer-aided analysis software. The first and last US examinations were considered in the analysis. The observed/expected total lung volumes were calculated. Main outcomes were perinatal death (up to 28 days of life) and respiratory morbidity (orotracheal intubation with mechanical respiratory support >48 hours). Results-Twelve of 19 fetuses (63.2%) survived. Among the survivors, 7 (58.3%) had severe respiratory morbidity. The observed/expected total lung volume at the last US examination before birth was significantly associated with perinatal death (P < .01) and respiratory morbidity (P < .01) as well as fetal hydrops (P < .01) and bilateral effusion (P = .01). Conclusions-Fetal total lung volumes may be useful for the prediction of perinatal outcomes in primary pleural effusion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The numerical simulation of flows of highly elastic fluids has been the subject of intense research over the past decades with important industrial applications. Therefore, many efforts have been made to improve the convergence capabilities of the numerical methods employed to simulate viscoelastic fluid flows. An important contribution for the solution of the High-Weissenberg Number Problem has been presented by Fattal and Kupferman [J. Non-Newton. Fluid. Mech. 123 (2004) 281-285] who developed the matrix-logarithm of the conformation tensor technique, henceforth called log-conformation tensor. Its advantage is a better approximation of the large growth of the stress tensor that occur in some regions of the flow and it is doubly beneficial in that it ensures physically correct stress fields, allowing converged computations at high Weissenberg number flows. In this work we investigate the application of the log-conformation tensor to three-dimensional unsteady free surface flows. The log-conformation tensor formulation was applied to solve the Upper-Convected Maxwell (UCM) constitutive equation while the momentum equation was solved using a finite difference Marker-and-Cell type method. The resulting developed code is validated by comparing the log-conformation results with the analytic solution for fully developed pipe flows. To illustrate the stability of the log-conformation tensor approach in solving three-dimensional free surface flows, results from the simulation of the extrudate swell and jet buckling phenomena of UCM fluids at high Weissenberg numbers are presented. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The vestibular-ocular reflex assessment is important, but not enough. Tridimensional electromagnetic sensor systems represent a new method to assess posturography. Aim: To assess body sway in healthy subjects who had positive Dix Hallpike and Epley maneuvers and with other vestibular dysfunctions by means of a three-dimensional system. Study design: Prospective. Materials and Methods: We had 23 healthy women, 15 with peripheral vestibular dysfunction found upon caloric test and 10 with positive Epley and Dix Hallpike maneuvers. All tests performed in the following positions: open and closed eyes on stable and unstable surfaces. Results: With the Eyes Open and on a stable surface, p < 0.01 between the control group and the one with peripheral vestibular dysfunction in all variables, except the a-p maximum, full speed and mediolateral trajectory velocity, which had a p < 0.01 between the group with vestibular dysfunction and controls in all positions. The group with positive Epley and Dix Hallpike maneuvers had p < 0.01 at full speed and in its components in the x and y in positions with open and eyes closed on an unstable surface. Conclusion: The tridimensional electromagnetic sensors system was able to generate reliable information about body sway in the study volunteers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The existence and stability of three-dimensional (3D) solitons, in cross-combined linear and nonlinear optical lattices, are investigated. In particular, with a starting optical lattice (OL) configuration such that it is linear in the x-direction and nonlinear in the y-direction, we consider the z-direction either unconstrained (quasi-2D OL case) or with another linear OL (full 3D case). We perform this study both analytically and numerically: analytically by a variational approach based on a Gaussian ansatz for the soliton wavefunction and numerically by relaxation methods and direct integrations of the corresponding Gross-Pitaevskii equation. We conclude that, while 3D solitons in the quasi-2D OL case are always unstable, the addition of another linear OL in the z-direction allows us to stabilize 3D solitons both for attractive and repulsive mean interactions. From our results, we suggest the possible use of spatial modulations of the nonlinearity in one of the directions as a tool for the management of stable 3D solitons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Myelodysplastic syndromes (MDS) are a group of disorders characterized by cytopenias, with a propensity for evolution into acute myeloid leukemias (AML). This transformation is driven by genomic instability, but mechanisms remain unknown. Telomere dysfunction might generate genomic instability leading to cytopenias and disease progression. Experimental Design: We undertook a pilot study of 94 patients with MDS (56 patients) and AML (38 patients). The MDS cohort consisted of refractory cytopenia with multilineage dysplasia (32 cases), refractory anemia (12 cases), refractory anemia with excess of blasts (RAEB) 1 (8 cases), RAEB2 (1 case), refractory anemia with ring sideroblasts (2 cases), and MDS with isolated del(5q) (1 case). The AML cohort was composed of AML-M4 (12 cases), AML-M2 (10 cases), AML-M5 (5 cases), AML-M0 (5 cases), AML-M1 (2 cases), AML-M4eo (1 case), and AML with multidysplasia-related changes (1 case). Three-dimensional quantitative FISH of telomeres was carried out on nuclei from bone marrow samples and analyzed using TeloView. Results: We defined three-dimensional nuclear telomeric profiles on the basis of telomere numbers, telomeric aggregates, telomere signal intensities, nuclear volumes, and nuclear telomere distribution. Using these parameters, we blindly subdivided the MDS patients into nine subgroups and the AML patients into six subgroups. Each of the parameters showed significant differences between MDS and AML. Combining all parameters revealed significant differences between all subgroups. Three-dimensional telomeric profiles are linked to the evolution of telomere dysfunction, defining a model of progression from MDS to AML. Conclusions: Our results show distinct three-dimensional telomeric profiles specific to patients with MDS and AML that help subgroup patients based on the severity of telomere dysfunction highlighted in the profiles. Clin Cancer Res; 18(12); 3293-304. (C) 2012 AACR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to evaluate the multisegmental static postural balance of active eutrophic and obese elderly women using a three-dimensional system under different sensory conditions. METHODS: A cross-sectional study was conducted on 31 elderly women (16 eutrophic and 15 obese) aged 65 to 75 years. The following anthropometric measurements were obtained: weight, height, waist and hip circumference, and handgrip strength. The physical activity level was evaluated using the International Physical Activity Questionnaire. Body composition was measured using the deuterium oxide dilution technique. The Polhemus (R) Patriot (three-dimensional) equipment was used to measure the parameters of postural balance along the anteroposterior and laterolateral axes. The data acquisition involved one trial of 60 s to test the limit of stability and four trials of 90 s each under the following conditions: (1) eyes open, stable surface; (2) eyes closed, stable surface; (3) eyes open, unstable surface; and (4) eyes closed, unstable surface. RESULTS: For the limit of stability, significant differences were observed in the maximum anteroposterior and laterolateral displacement (p<0.01) and in the parameter maximum anteroposterior displacement in the eyes closed stable surface condition (p<0.01) and maximum anteroposterior and laterolateral displacement in the eyes open unstable surface (p<0.01 and p = 0.03) and eyes closed unstable surface (p<0.01 and p<0.01) conditions. CONCLUSIONS: Obese elderly women exhibited a lower stability limit (lower sway area) compared with eutrophic women, leaving them more vulnerable to falls.