18 resultados para reproducibility of calculated surfaces
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This work investigates the eproducibility of precipitation simulated with an atmospheric general circulation model (AGCM) forced by subtropical South Atlantic sea surface temperature (SST) anomalies. This represents an important test of the model prior to investigating the impact of SSTs on regional climate. A five-member ensemble run was performed using the National Center for Atmospheric Research (NCAR) Community Climate Model, version 3 (CCM3). The CCM3 was forced by observed monthly SST over the South Atlantic from 20 to 60 S. The SST dataset used is from the Hadley Centre covering the period of September 1949-October 2001; this covers more than 50 yr of simulation. A statistical technique is used to determine the reproducibility in the CCM3 runs and to assess potential predictability in precipitation. Empirical orthogonal function analysis is used to reconstruct the ensemble using the most reproducible forced modes in order to separate the atmospheric response to local SST forcing from its internal variability. Results for reproducibility show a seasonal dependence, with higher values during austral autumn and spring. The spatial distribution of reproducibility shows that the tropical atmosphere is dominated by the underlying SSTs while variations in the subtropical-extratropical regions are primarily driven by internal variability. As such, changes in the South Atlantic convergence zone (SACZ) region are mainly dominated by internal atmospheric variability while the ITCZ has greater external dependence, making it more predictable. The reproducibility distribution reveals increased values after the reconstruction of the ensemble.
Resumo:
In this work we compare the simple singularities of germs from R-2 to R-p with multiplicity 2 or 3 with the singularities appearing in the set of 2-ruled surfaces. We also study the topological type of all finitely determined singularities by studying generic projections of these singularities in R-3. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
There is a controversy about the best way to report results after bariatric surgery. Several indices have been proposed over the years such as percentage of total weight loss (%TWL), percentage of excess weight loss (%EWL), and percentage of excess body mass index loss (%EBMIL). More recently, it has been suggested to individualize the body mass index (BMI) goal to be achieved by the patients (predicted BMI-PBMI). The objective was to assess the reproducibility of this PBMI in our service. In this retrospective study, we assessed the %TWL, %EWL, %EBMIL (with expected BMI of 25 kg/m(2)), and %EBMIL (with PBMI) over 4 years of observation in two groups of patients: BMI < 50 kg/m(2) and BMI a parts per thousand yen50 kg/m(2). The medical records of 403 patients were studied. From 18 to 42 months after surgery, %TWL was higher in the superobese group, whereas %EWL was similar for the two groups. %EBMIL was higher in less obese patients up to 24 months and similar thereafter. In contrast, %EBMIL with PBMI was greater in the superobese group, although it never reached the 100% goal. We conclude that %EBMIL results according to PBMI were not reproducible in our institution. There is a need to elaborate a new easy-to-obtain and reproducible index.
Resumo:
International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.
Resumo:
The aim of this study was to determine whether image artifacts caused by orthodontic metal accessories interfere with the accuracy of 3D CBCT model superimposition. A human dry skull was subjected three times to a CBCT scan: at first without orthodontic brackets (T1), then with stainless steel brackets bonded without (T2) and with orthodontic arch wires (T3) inserted into the brackets' slots. The registration of image surfaces and the superimposition of 3D models were performed. Within-subject surface distances between T1-T2, T1-T3 and T2-T3 were computed and calculated for comparison among the three data sets. The minimum and maximum Hausdorff Distance units (HDu) computed between the corresponding data points of the T1 and T2 CBCT 3D surface images were 0.000000 and 0.049280 HDu, respectively, and the mean distance was 0.002497 HDu. The minimum and maximum Hausdorff Distances between T1 and T3 were 0.000000 and 0.047440 HDu, respectively, with a mean distance of 0.002585 HDu. In the comparison between T2 and T3, the minimum, maximum and mean Hausdorff Distances were 0.000000, 0.025616 and 0.000347 HDu, respectively. In the current study, the image artifacts caused by metal orthodontic accessories did not compromise the accuracy of the 3D model superimposition. Color-coded maps of overlaid structures complemented the computed Hausdorff Distances and demonstrated a precise fusion between the data sets.
Resumo:
Dental implants have increased the use of titanium and titanium alloys in prosthetic applications. Whitening toothpastes with peroxides are available for patients with high aesthetic requirements, but the effect of whitening toothpastes on titanium surfaces is not yet known, although titanium is prone to fluoride ion attack. Thus, the aim of the present study was to compare Ti-5Ta alloy to cp Ti after toothbrushing with whitening and conventional toothpastes. Ti-5Ta (%wt) alloy was melted in an arc melting furnace and compared with cp Ti. Disks and toothbrush heads were embedded in PVC rings to be mounted onto a toothbrushing test apparatus. A total of 260,000 cycles were carried out at 250 cycles/minute under a load of 5 N on samples immersed in toothpaste slurries. Surface roughness and Vickers microhardness were evaluated before and after toothbrushing. One sample of each material/toothpaste was analyzed by Scanning Electron Microscopy (SEM) and compared with a sample that had not been submitted to toothbrushing. Surface roughness increased significantly after toothbrushing, but no differences were noted after toothbrushing with different toothpastes. Toothbrushing did not significantly affect sample microhardness. The results suggest that toothpastes that contain and those that do not contain peroxides in their composition have different effects on cp Ti and Ti-5Ta surfaces. Although no significant difference was noted in the microhardness and roughness of the surfaces brushed with different toothpastes, both toothpastes increased roughness after toothbrushing.
Resumo:
The practice of running has consistently increased worldwide, and with it, related lower limb injuries. The type of running surface has been associated with running injury etiology, in addition other factors, such as the relationship between the amount and intensity of training. There is still controversy in the literature regarding the biomechanical effects of different types of running surfaces on foot-floor interaction. The aim of this study was to investigate the influence of running on asphalt, concrete, natural grass, and rubber on in-shoe pressure patterns in adult recreational runners. Forty-seven adult recreational runners ran twice for 40 m on all four different surfaces at 12 +/- 5% km . h(-1). Peak pressure, pressure-time integral, and contact time were recorded by Pedar X insoles. Asphalt and concrete were similar for all plantar variables and pressure zones. Running on grass produced peak pressures 9.3% to 16.6% lower (P < 0.001) than the other surfaces in the rearfoot and 4.7% to 12.3% (P < 0.05) lower in the forefoot. The contact time on rubber was greater than on concrete for the rearfoot and midfoot. The behaviour of rubber was similar to that obtained for the rigid surfaces - concrete and asphalt - possibly because of its time of usage (five years). Running on natural grass attenuates in-shoe plantar pressures in recreational runners. If a runner controls the amount and intensity of practice, running on grass may reduce the total stress on the musculoskeletal system compared with the total musculoskeletal stress when running on more rigid surfaces, such as asphalt and concrete.
Resumo:
The use of patient-orientated questionnaires is of utmost importance in assessing the outcome of spine surgery. Standardisation, using a common set of outcome measures, is essential to aid comparisons across studies/in registries. The Core Outcome Measures Index (COMI) is a short, multidimensional outcome instrument validated for patients with spinal disorders. This study aimed to produce a Brazilian-Portuguese version of the COMI. A cross-cultural adaptation of the COMI into Brazilian-Portuguese was carried out using established guidelines. 104 outpatients with chronic LBP (> 3 months) were recruited from a Public Health Spine Medical Care Centre. They completed a questionnaire booklet containing the newly translated COMI, and other validated symptom-specific questionnaires: Oswestry Disability Index (ODI) and Roland Morris disability scale (RM), and a pain visual analogue scale. All patients completed a second questionnaire within 7-10 days to assess reproducibility. The COMI summary score displayed minimal floor and ceiling effects. On re-test, the responses for each individual domain of the COMI were within 1 category in 98% patients for the domain 'function', 96% for 'symptom-specific well-being', 97% for 'general quality of life', 99% for 'social disability' and 100% for 'work disability'. The intraclass correlation coefficients (ICC2,1) for COMI pain and COMI summary scores were 0.91-0.96, which compared favourably with the corresponding values for the RM (ICC, 0.99) and ODI (ICC, 0.98). The standard error of measurement for the COMI was 0.6, giving a "minimum detectable change" (MDC95%) of approximately 1.7 points i.e., the minimum change to be considered "real change" beyond measurement error. The COMI scores correlated as hypothesised (Rho, 0.4-0.8) with the other symptom-specific questionnaires. The reproducibility of the Brazilian-Portuguese version of the COMI was comparable to that of other language versions. The COMI scores correlated in the expected manner with existing but longer symptom-specific questionnaires suggesting good convergent validity for the COMI. The Brazilian-Portuguese COMI represents a valuable tool for Brazilian study-centres in future multicentre clinical studies and surgical registries.
Resumo:
Since there was no Portuguese questionnaire to evaluate cutaneous allodynia, which has been pointed out as a risk factor of migraine, we aimed to perform the cross-cultural adaptation of the 12 item Allodynia Symptom Checklist for the Brazilian population and to test its measurement properties. It consisted in six stages: translation, synthesis, back translation, revision by a specialist committee, pretest and submission the documents to the committee. In the pretest stage, the questionnaire was applied to 30 migraineurs of both sexes, who had some difficulty in understanding it. Thus, a second version was applied to 30 additional subjects, with no difficulties being reported. The mean filling out time was 3'36", and the internal consistency was 0.76. To test reproducibility, 15 other subjects filled out the questionnaire at two different times, it was classified as moderate (weighted kappa=0.58). We made available to Brazilian population an easy, quick and reliable questionnaire.
Resumo:
The assessment of adenoids by x-ray imaging has been the topic of heated debate, but few studies have looked into the reliability of most existing radiographic parameters. Objective: This study aims to verify the intra-examiner and inter-examiner reproducibility of the adenoid radiographic assessment methods. Materials and Methods: This is a cross-sectional case series study. Forty children of both genders aged between 4 and 14 were enrolled. They were selected based on complaints of nasal obstruction or mouth breathing and suspicion of pharyngeal tonsil hypertrophy. Cavum x-rays and orthodontic teleradiographs were assessed by two examiners in quantitative and categorical terms. Results: All quantitative parameters in both x-ray modes showed excellent intra and inter-examiner reproducibility. Relatively better performance was observed in categorical parameters used in cavum x-ray assessment by C-Kurien, C-Wang, C-Fujioka, and C-Elwany over C-Cohen and C-Ysunza. As for orthodontic teleradiograph grading systems, C-McNamara has been proven to be more reliable than C-Holmberg. Conclusion: Most instruments showed adequate reproducibility levels. However, more research is needed to properly determine the accuracy and viability of each method.
Resumo:
The objectives of this study were to assess the interrater reproducibility of the instrument to classify pediatric patients with cancer; verify the adequacy of the patient classification instrument for pediatric patients with cancer; and make a proposal for changing the instrument, thus allowing for the necessary adjustments for pediatric oncology patients. A total of 34 pediatric inpatients of a Cancer Hospital were evaluated by the teams of physicians, nurses and nursing technicians. The Kappa coefficient was used to rate the agreement between the scores, which revealed a moderate to high value in the objective classifications, and a low value in the subjective. In conclusion, the instrument is reliable and reproducible, however, it is suggested that to classify pediatric oncology patients, some items should be complemented in order to reach an outcome that is more compatible with the reality of this specific population.
Resumo:
O objetivo deste estudo foi analisar a reprodutibilidade de parâmetros no domínio da frequência do sinal eletromiográfico (EMG) utilizados na caracterização da fadiga muscular localizada. Quinze sujeitos do sexo masculino foram submetidos a um teste de fadiga baseado na extensão isométrica de joelho, sendo realizados em três momentos distintos com intervalos de sete dias. Para avaliar a reprodutibilidade dos dados entres os testes calculou-se o coeficiente de correlação intraclasse (CCI) para a frequência mediana (Fmed) no tempo total de exercício (FmedT), para a Fmed obtida a cada 10% do tempo de exercício (Fmed10%) e para as potências das bandas de frequência, obtidas da divisão do espectro de potência a cada 20 Hz. Os resultados demonstraram: (1) boa reprodutibilidade para a FmedT; (2) boa reprodutibilidade para a Fmed10%; e (3) maior variação no sinal EMG nas bandas de 20 a 120 Hz, no qual se destacam as bandas de 20-40 Hz e de 40-60 Hz, demonstrando maior sensibilidade ao processo de fadiga muscular. Conclui-se que a Fmed é uma variável que apresenta boa reprodutibilidade e que a análise fragmentada do espectro de potência, por meio das bandas de frequência, demonstrou-se sensível as variações que ocorrem no sinal EMG durante a instalação do processo de fadiga, tendo potencial para se tornar um novo método para a caracterização da fadiga muscular localizada.
Resumo:
Pt extended surfaces and nanoparticle electrodes are used to understand the origin of anomalous activities for electrocatalytic reactions in alkaline electrolytes as a function of cycling/time. Scanning tunneling microscopy (STM) of the surfaces before and after cycling in alkaline electrolytes was used to understand the morphology of the impurities and their impact on the catalytic sites. The nature of the contaminant species is identified as 3d-transition metal cations, and the formation of hydr(oxy)oxides of these elements is established as the main reason for the observed behavior. We find that, while for the oxygen reduction reaction (ORR) and the hydrogen oxidation reaction (HOR) the blocking of the sites by the undesired 3d-transition metal hydr(oxy)oxide species leads to deactivation of the reaction activities, the CO oxidation reaction and the hydrogen evolution reaction (HER) can have beneficial effects from the same impurities, the latter being dependent on the exact nature of the adsorbing species. These results show the significance of impurities present in real electrolytes and their impact on electrocatalysis.
Resumo:
Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.
Resumo:
Background and objectives: Literature on preemptive analgesia is controversial. Reliability of results and difficult reproducibility of research contribute for non-elucidation of the subject. The aim of this study is to test the efficacy of oral ketoprofen (150 mg) preemptively administrated two days before third molar surgery, compared with postoperative administration in the same patient. Methods: Thirteen patients underwent surgical removal of bilateral third molar in two separate procedures. In a random and double blind procedure, oral ketoprofen 150 mg was administered every 12 hours two days before surgery and, after the procedure, the same drug was administered for three days. On the other side, a control (placebo) was used orally every 12 hours two days before surgery and, after the procedure, ketoprofen 150 mg was administered every 12 hours for three days. Postoperative pain was assessed by visual analogue scale, nominal scale, and amount of rescue analgesics consumed. Results: There was no statistically significant difference in postoperative pain between the preemptive treatment and control. Conclusion: In this experimental model, preemptive analgesia was not effective in reducing postoperative pain in surgical extraction of third molar compared with the postoperative administration of the same drug.