30 resultados para plasma immersion ion implantation and deposition
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
We describe work in which gold nanoparticles were formed in diamond-like carbon (DLC), thereby generating a Au-DLC nanocomposite. A high-quality, hydrogen-free DLC thin film was formed by filtered vacuum arc plasma deposition, into which gold nanoparticles were introduced using two different methods. The first method was gold ion implantation into the DLC film at a number of decreasing ion energies, distributing the gold over a controllable depth range within the DLC. The second method was co-deposition of gold and carbon, using two separate vacuum arc plasma guns with suitably interleaved repetitive pulsing. Transmission electron microscope images show that the size of the gold nanoparticles obtained by ion implantation is 3-5 nm. For the Au-DLC composite obtained by co-deposition, there were two different nanoparticle sizes, most about 2 nm with some 6-7 nm. Raman spectroscopy indicates that the implanted sample contains a smaller fraction of sp(3) bonding for the DLC, demonstrating that some sp(3) bonds are destroyed by the gold implantation. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4757029]
Resumo:
This manuscript reports on the fabrication of plasmonic substrates using cathodic arc plasma ion implantation, in addition to their performance as SERS substrates. The technique allows for the incorporation of a wide layer of metallic nanoparticles into a polymer matrix, such as PMMA. The ability to pattern different structures using the PMMA matrix is one of the main advantages of the fabrication method. This opens up new possibilities for obtaining tailored substrates with enhanced performance for SERS and other surface-enhanced spectroscopies, as well as for exploring the basic physics of patterned metal nanostructures. The architecture of the SERS-active substrate was varied using three adsorption strategies for incorporating a laser dye (rhodamine): alongside the nanoparticles into the polymer matrix, during the polymer cure and within nanoholes lithographed on the polymer. As a proof-of-concept, we obtained the SERS spectra of rhodamine for the three types of substrates. The hypothesis of incorporation of rhodamine molecules into the polymer matrix during the cathodic arc plasma ion implantation was supported by FDTD (Finite-Difference Time-Domain) simulations. In the case of arrays of nanoholes, rhodamine molecules could be adsorbed directly on the gold surface, then yielding a well-resolved SERS spectrum for a small amount of analyte owing to the short-range interactions and the large longitudinal field component inside the nanoholes. The results shown here demonstrate that the approach based on ion implantation can be adapted to produce reproducible tailored substrates for SERS and other surface-enhanced spectroscopies.
Resumo:
We describe an approach to ion implantation in which the plasma and its electronics are held at ground potential and the ion beam is formed and injected energetically into a space held at high negative potential. The technique allows considerable savings both economically and technologically, rendering feasible ion implantation applications that might otherwise not be possible for many researchers and laboratories. Here, we describe the device and the results of tests demonstrating Nb implantation at 90 keV ion energy and dose about 2 x 10(16) cm(-2). (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4768699]
Resumo:
A comprehensive study of pulsed nitriding in AISI H13 tool steel at low temperature (400 degrees C) is reported for several durations. X-ray diffraction results reveal that a nitrogen enriched compound (epsilon-Fe2-3N, iron nitride) builds up on the surface within the first process hour despite the low process temperature. Beneath the surface, X-ray Wavelength Dispersive Spectroscopy (WDS) in a Scanning Electron Microscope (SEM) indicates relatively higher nitrogen concentrations (up to 12 at.%) within the diffusion layer while microscopic nitrides are not formed and existing carbides are not dissolved. Moreover, in the diffusion layer, nitrogen is found to be dispersed in the matrix and forming nanosized precipitates. The small coherent precipitates are observed by High-Resolution Transmission Electron Microscopy (HR-TEM) while the presence of nitrogen is confirmed by electron energy loss spectroscopy (EELS). Hardness tests show that the material hardness increases linearly with the nitrogen concentration, reaching up to 14.5 GPa in the surface while the Young Modulus remains essentially unaffected. Indeed, the original steel microstructure is well preserved even in the nitrogen diffusion layer. Nitrogen profiles show a case depth of about similar to 43 mu m after nine hours of nitriding process. These results indicate that pulsed plasma nitriding is highly efficient even at such low temperatures and that at this process temperature it is possible to form thick and hard nitrided layers with satisfactory mechanical properties. This process can be particularly interesting to enhance the surface hardness of tool steels without exposing the workpiece to high temperatures and altering its bulk microstructure. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
Chemical disinfectants are usually associated with mechanical methods to remove stains and reduce biofilm formation. This study evaluated the effect of disinfectants on release of metal ions and surface roughness of commercially pure titanium, metal alloys, and heat-polymerized acrylic resin, simulating 180 immersion trials. Disk-shaped specimens were fabricated with commercially pure titanium (Tritan), nickel-chromium-molybdenum-titanium (Vi-Star), nickel-chromium (Fit Cast-SB Plus), and nickel-chromium-beryllium (Fit Cast-V) alloys. Each cast disk was invested in the flasks, incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n=5) were immersed in these solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous, and Polident. Deionized water was used as a control. The quantitative analysis of metal ion release was performed using inductively coupled plasma mass spectrometry (ELAN DRC II). A surface analyzer (Surftest SJ-201P) was used to measure the surface roughness (µm). Data were recorded before and after the immersions and evaluated by two-way ANOVA and Tukey's test (α=0.05). The nickel release proved most significant with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. There was a significant difference in surface roughness of the resin (p=0.011) after immersion. Cepacol caused significantly higher resin roughness. The immersion products had no influence on metal roughness (p=0.388). It could be concluded that the tested alloys can be considered safe for removable denture fabrication, but disinfectant solutions as Cepacol and Medical Interporous tablet for daily denture immersion should be used with caution because it caused greater resin surface roughness and greater ion release, respectively.
Resumo:
We describe an approach to ion implantation in which the plasma and its electronics are held at ground potential and the ion beam is injected into a space held at high negative potential, allowing considerable savings both economically and technologically. We used an “inverted ion implanter” of this kind to carry out implantation of gold into alumina, with Au ion energy 40 keV and dose (3–9) × 1016 cm−2. Resistivity was measured in situ as a function of dose and compared with predictions of a model based on percolation theory, in which electron transport in the composite is explained by conduction through a random resistor network formed by Au nanoparticles. Excellent agreement is found between the experimental results and the theory.
Resumo:
We have explored the suitability and characteristics of interface tailoring as a tool for enhancing the adhesion of hydrogen-free diamond-like carbon (DLC) thin films to silicon substrates. DLC films were deposited on silicon with and without application of an initial high energy carbon ion bombardment phase that formed a broad Si-C interface of gradually changing Si:C composition. The interface depth profile was calculated using the TRIDYN simulation program, revealing a gradient of carbon concentration including a region with the stoichiometry of silicon carbide. DLC films on silicon, with and without interface tailoring, were characterized using Raman spectroscopy, scanning electron microscopy, atomic force microscopy and scratch tests. The Raman spectroscopy results indicated sp3-type carbon bonding content of up to 80%. Formation of a broadened Si:C interface as formed here significantly enhances the adhesion of DLC films to the underlying silicon substrate. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
The synthesis, characterization and formation of Langmuir-Blodgett (LB)films for the luminescent [(C12H25)(2)(CH3)(2)N][Eu(tta)(4)] complex, where [(C12H25)(2)(CH3)(2)](N+) is didodecyldimethylammonium and the tta ligand is thenoyltrifluoroacetone, are reported. The coordination of tta ligands to the Eu3+ ion was confirmed by FTIR spectroscopy and the emission spectrum comprised bands corresponding to D-5(0) -> F-7(0-4) transitions. The lifetime (tau) from the emission state (D-5(0))was 0.41 ms, measured by monitoring the hypersensitive D-5(0) -> F-7(2) transition, with the curve being fitted with a first-order exponential function. The surface pressure-area isotherm indicated that the anionic complex may form condensed structures at the air-water interface due to the amphiphilic properties of the counter ion and the beta-diketone ligand. Y-type LB films of [(C12H25)(2)(CH3)(2)N][Eu(tta)(4)] were deposited on quartz substrates, with preserved luminescence and a band assigned to the D-5(0) -> F-7(2) transition. The molecular arrangement at the air/water interface and the preserved luminescence in LB films are consistent with theoretical predictions using a semi-empirical Sparkle/AM1 calculation method for the molecule in vacuum. These tools were used for the first time to predict the behavior of organized films.
Resumo:
Introduction: The aim of this study was to assess the effect of nitrogen ion implantation on the flexibility of rotary nickel-titanium (NiTi) instruments as measured by the load required to bend implanted and nonimplanted instruments at a 30 degrees angle. Methods: Thirty K3 files, size #40, 0.02 taper and 25-mm length, were allocated into 2 groups as follows: group A, 15 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), voltage 200 KeV, current density 1 mu A/cm(2), temperature 130 degrees C, and vacuum conditions of 10 x 10(-6) mm Hg for 6 hours; and group B, 15 nonimplanted files. One extra file was used for process control. All instruments were subjected to bend testing on a modified troptometer, with measurement of the load required for flexure to an angle of 30 degrees. The Mann-Whitney U test was used for statistical analysis. Findings with P <.05 were considered significant. Results: The mean load required to bend instruments at a 30 degrees angle was 376.26 g for implanted instruments and 383.78 g for nonimplanted instruments. The difference was not statistically significant. Conclusions: Our findings show that nitrogen ion implantation has no appreciable effect on the flexibility of NiTi instruments. (J Endod 2012;38:673-675)
Resumo:
There is special interest in the incorporation of metallic nanoparticles in a surrounding dielectric matrix for obtaining composites with desirable characteristics such as for surface plasmon resonance, which can be used in photonics and sensing, and controlled surface electrical conductivity. We investigated nanocomposites produced through metallic ion implantation in insulating substrate, where the implanted metal self-assembles into nanoparticles. During the implantation, the excess of metal atom concentration above the solubility limit leads to nucleation and growth of metal nanoparticles, driven by the temperature and temperature gradients within the implanted sample including the beam-induced thermal characteristics. The nanoparticles nucleate near the maximum of the implantation depth profile (projected range), that can be estimated by computer simulation using the TRIDYN. This is a Monte Carlo simulation program based on the TRIM (Transport and Range of Ions in Matter) code that takes into account compositional changes in the substrate due to two factors: previously implanted dopant atoms, and sputtering of the substrate surface. Our study suggests that the nanoparticles form a bidimentional array buried few nanometers below the substrate surface. More specifically we have studied Au/PMMA (polymethylmethacrylate), Pt/PMMA, Ti/alumina and Au/alumina systems. Transmission electron microscopy of the implanted samples showed the metallic nanoparticles formed in the insulating matrix. The nanocomposites were characterized by measuring the resistivity of the composite layer as function of the dose implanted. These experimental results were compared with a model based on percolation theory, in which electron transport through the composite is explained by conduction through a random resistor network formed by the metallic nanoparticles. Excellent agreement was found between the experimental results and the predictions of the theory. It was possible to conclude, in all cases, that the conductivity process is due only to percolation (when the conducting elements are in geometric contact) and that the contribution from tunneling conduction is negligible.
Resumo:
Introduction: The increasing number of reports on the relation between transfusion of stored red blood cells (RBCs) and adverse patient outcome has sparked an intense debate on the benefits and risks of blood transfusions. Meanwhile, the pathophysiological mechanisms underlying this postulated relation remain unclear. The development of hemolysis during storage might contribute to this mechanism by release of free hemoglobin (fHb), a potent nitric oxide (NO) scavenger, which may impair vasodilation and microcirculatory perfusion after transfusion. The objective of this prospective observational pilot study was to establish whether RBC transfusion results in increased circulating fHb levels and plasma NO consumption. In addition, the relation between increased fHb values and circulating haptoglobin, its natural scavenger, was studied. Methods: Thirty patients electively received 1 stored packed RBC unit (n = 8) or 2 stored packed RBC units (n = 22). Blood samples were drawn to analyze plasma levels of fHb, haptoglobin, and NO consumption prior to transfusion, and 15, 30, 60 and 120 minutes and 24 hours after transfusion. Differences were compared using Pearson's chi-square test or Fisher's exact test for dichotomous variables, or an independent-sample t test or Mann-Whitney U test for continuous data. Continuous, multiple-timepoint data were analyzed using repeated one-way analysis of variance or the Kruskall-Wallis test. Correlations were analyzed using Spearman or Pearson correlation. Results: Storage duration correlated significantly with fHb concentrations and NO consumption within the storage medium (r = 0.51, P < 0.001 and r = 0.62, P = 0.002). fHb also significantly correlated with NO consumption directly (r = 0.61, P = 0.002). Transfusion of 2 RBC units significantly increased circulating fHb and NO consumption in the recipient (P < 0.001 and P < 0.05, respectively), in contrast to transfusion of 1 stored RBC unit. Storage duration of the blood products did not correlate with changes in fHb and NO consumption in the recipient. In contrast, pre-transfusion recipient plasma haptoglobin levels inversely influenced post-transfusion fHb concentrations. Conclusion: These data suggest that RBC transfusion can significantly increase post-transfusion plasma fHb levels and plasma NO consumption in the recipient. This finding may contribute to the potential pathophysiological mechanism underlying the much-discussed adverse relation between blood transfusions and patient outcome. This observation may be of particular importance for patients with substantial transfusion requirements.
Resumo:
We examine hemolymph ion regulation and the kinetic properties of a gill microsomal (Na+, K+)-ATPase from the intertidal hermit crab, Clibanarius vittatus, acclimated to 45 parts per thousand salinity for 10 days. Hemolymph osmolality is hypo-regulated (1102.5 +/- 22.1 mOsm kg(-1) H2O) at 45 parts per thousand but elevated compared to fresh-caught crabs (801.0 +/- 40.1 mOsm kg(-1) H2O). Hemolymph [Na+ (323.0 +/- 2.5 mmol L-1) and [Me2+) (34.6 +/- 1.0 mmol L-1) are hypo-regulated while [Ca2+] (22.5 +/- 0.7 mmol L-1) is hyper-regulated; [K+] is hyper-regulated in fresh-caught crabs (17.4 +/- 0.5 mmol L-1) but hypo-regulated (6.2 +/- 0.7 mmol L-1) at 45 parts per thousand. Protein expression patterns are altered in the 45 parts per thousand-acclimated crabs, although Western blot analyses reveal just a single immunoreactive band, suggesting a single (Na+, K+)-ATPase alpha-subunit isoform, distributed in different density membrane fractions. A high-affinity (Vm = 46.5 +/- 3.5 U mg(-1); K-0.5 = 7.07 +/- 0.01 mu mol L-1) and a low-affinity ATP binding site (Vm = 108.1 +/- 2.5 U mg(-1); K-0.5 = 0.11 +/- 0.3 mmol L-1), both obeying cooperative kinetics, were disclosed. Modulation of (Na+, K+)-ATPase activity by Mg2+, K+ and NH4+ also exhibits site-site interactions, but modulation by Na+ shows Michaelis-Menten kinetics. (Na+, K+)-ATPase activity is synergistically stimulated up to 45% by NH4+ plus K+. Enzyme catalytic efficiency for variable [K+] and fixed [NH4+] is 10-fold greater than for variable [NH4+] and fixed [K+]. Ouabain inhibited approximate to 80% of total ATPase activity (K-I=464.7 +/- 23.2 mu mol L-1), suggesting that ATPases other than (Na+, K+)-ATPase are present. While (Na+, K+)-ATPase activities are similar in fresh-caught (around 142 nmol Pi min(-1) mg(-1)) and 45 parts per thousand-acclimated crabs (around 154 nmol Pi min(-1) mg(-1)), ATP affinity decreases 110-fold and Na+ and K+ affinities increase 2-3-fold in 45 parts per thousand-acclimated crabs. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Objective: The aim of this study was to investigate the effects of PRP on SAOS-2 cells in terms of cytokine expression, cell activity and oxidative stress. Design: Cell line SAOS-2 (1 x 10(5) cells/mL) were grown in culture medium alpha-MEM with 10% FBS for 24 h and stimulated (or not) with PRP at concentrations of 3, 10 and 20%, LPS (E. coli, 10 g/mL) and IL-1 beta (1 mg/mL) for 24 h. The supernatant was collected and analyzed for the expression of cytokines in a panel array, ALP using a commercial kit and NO2- with Griess reaction method. Also, the cells were analyzed using Western blot for RANKL and slot blotting for nitrotyrosine expression. Result: There were no significant differences amongst the groups in terms of NO2-, protein nitrotyrosine content and RANKL expression. However, all stimuli increased ALP activity and in case of PRP, it was in a dose-dependent manner (p < 0.001). Also, all stimuli induced an increase in cytokines and chemokines expression, but only PRP promoted an increase of component C5, sICAM-1 and RANTES expression. Whilst IL-1 receptor antagonist (IL-1ra) expression was down-regulated by PRP, both LPS and IL-1 beta caused up-regulation of this cytokine. Conclusions: PRP can stimulate osteoblast activity and cytokine/chemokine release, as well as indicate some of the mediators that can (and cannot) be involved in this activation. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Objective. - The aim of this study was to identify the effects of strength training on plasma parameters, body composition and the liver of ovariectomized rats. Methods. - Wistar sedentary (SHAM), ovariectomized (OVX), and ovariectomized trained rats (strength training [OVX-EXE]) of 85% of one maximal repetition (1 RM), three times per week, for 10 weeks, were used on this study. We monitored the body weight and visceral (uterine, mesenteric and retroperitoneal) and subcutaneous adiposity, total cholesterol, triglycerides, HDL, blood glucose and liver morphology to identify the presence of macrovesicular steotosis (haematoxylin and eosin staining). Results. - We observed that strength training changed body weight (SHAM 293.0 +/- 14.5 g; OVX 342.6 +/- 10.8 g; OVX-EXE 317.7 +/- 11.9 g, P < 0.05), visceral and subcutaneous adiposity, glucose (SHAM 111.2 +/- 10.0 mg/dL; OVX 147.4 +/- 18.8 mg/dL; OVX-EXE 118.5 +/- 2.2 mg/dL, P < 0.05), increased HDL (SHAM 82.7 +/- 1.4 mg/dL; OVX 64.6 +/- 2.8 mg/dL; OVX-EXE 91.4 +/- 2.6 mg/dL, P < 0.05) and reduced macrovesicular steatosis in liver tissue. Conclusions. - Considering the data obtained in this research, we emphasise the use of strength exercise training as a therapeutic means to combat or control the metabolic disturbances associated with menopause, including adiposity, and adverse changes in blood glucose, blood HDL and macrovesicular steatosis. (C) 2011 Elsevier Masson SAS. All rights reserved.
Resumo:
Abnormal matrix metalloproteinase (MMP)-9 levels may have a role in hypertensive disorders of pregnancy. We examined whether MMP-9 genetic polymorphisms (g.-1562C>T and g.-90(CA)(13-25)) modify plasma MMP-9 and tissue inhibitor of metalloproteinase (TIMP)-1 levels and the responses to antihypertensive therapy in 214 patients with preeclampsia (PE), 185 patients with gestational hypertension (GH) and a control group of 214 healthy pregnant (HP). Alleles for the g.-90(CA)(13-25) polymorphism were grouped L (low) (<21 CA repeats) or H (high) (>= 21 CA repeats). Plasma MMP-9 and TIMP-1 concentrations were measured by enzyme-linked immunosorbent assay. Plasma MMP-9 concentrations were not affected by genotypes or haplotypes in HP and PE groups, except for the g.-90(CA)(13-25) polymorphism: GH patients with the LH genotype for this polymorphism have higher MMP-9 levels than those with other genotypes. The T allele for the g.-1562C>T polymorphism and the H4 haplotype (combining T and H alleles) are associated with GH and lack of responsiveness to antihypertensive therapy in GH. The H2 haplotype (combining C and H alleles) was associated with lack of responsiveness to antihypertensive therapy in PE, but not in GH. In conclusion, our results show that MMP-9 genetic variants are associated with GH and suggest that MMP-9 haplotypes affect the responsiveness to antihypertensive therapy in hypertensive disorders of pregnancy. The Pharmacogenomics Journal (2012) 12, 489-498; doi: 10.1038/tpj.2011.31; published online 19 July 2011