6 resultados para absolute bar

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct reconstruction algorithm for complex conductivities in W-2,W-infinity(Omega), where Omega is a bounded, simply connected Lipschitz domain in R-2, is presented. The framework is based on the uniqueness proof by Francini (2000 Inverse Problems 6 107-19), but equations relating the Dirichlet-to-Neumann to the scattering transform and the exponentially growing solutions are not present in that work, and are derived here. The algorithm constitutes the first D-bar method for the reconstruction of conductivities and permittivities in two dimensions. Reconstructions of numerically simulated chest phantoms with discontinuities at the organ boundaries are included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To establish normative amplitude values for relative difference measurements of the middle latency response (MLR) in normal-hearing pediatrics and to determine if these measurements provided a significant reduction of within-group variability when compared to raw, absolute amplitude measures. A relative amplitude difference is defined in the present paper as the difference in Na-Pa amplitude between two electrodes (e.g. vertical bar Na-Pa at C3 minus Na-Pa at C4 vertical bar, or electrode effects) or between two ears (e.g. vertical bar Na-Pa on left ear stimulation minus Na-Pa on right ear stimulation vertical bar, or ear effects). In contrast, an absolute amplitude is defined as a single Na-Pa measurement made at one electrode for stimulation of one ear (e.g. Na-Pa measured at C3 on left ear stimulation). Design: Cross-sectional study. Study sample: 155 pediatrics with normal peripheral and central hearing, and no history of psychological, neurological, or learning disability issues. Results: Within-group variability was significantly smaller for relative differences when compared to absolute amplitude measures. Electrode effects showed significantly less variability than ear effects. Normative values for ear and electrode effects were reported. Conclusions: Relative differences may provide better utility in the clinical diagnosis of central auditory pathology in pediatrics when compared to absolute amplitude measures because these difference measures show significantly lower variability when examined across subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We revisit the issue of the constancy of the dark matter (DM) and baryonic Newtonian acceleration scales within the DM scale radius by considering a large sample of late-type galaxies. We rely on a Markov Chain Monte Carlo method to estimate the parameters of the halo model and the stellar mass-to-light ratio and then propagate the uncertainties from the rotation curve data to the estimate of the acceleration scales. This procedure allows us to compile a catalogue of 58 objects with estimated values of the B-band absolute magnitude M-B, the virial mass M-vir, and the DM and baryonic Newtonian accelerations (denoted as g(DM)(r(0)) and g(bar)(r(0)), respectively) within the scale radius r(0) which we use to investigate whether it is possible to define a universal acceleration scale. We find a weak but statistically meaningful correlation with M-vir thus making us argue against the universality of the acceleration scales. However, the results somewhat depend on the sample adopted so that a careful analysis of selection effects should be carried out before any definitive conclusion can be drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absolute configuration and solution-state conformers of three peperomin-type secolignans isolated from Peperomia blanda (Piperaceae) are unambiguously determined by using vibrational circular dichroism (VCD) spectroscopy associated with density functional theory (DFT) calculations. Advantages of VCD over the electronic form of CD for the analysis of diastereomers are also discussed. This work extends our growing knowledge about secondary metabolites within the Piperaceae family species while providing a definitive and straightforward method to assess the absolute stereochemistry of secolignans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reinvestigation of the monoterpene chromane ester enriched fraction from Peperomia obtusifolia using chiral chromatography led to the identification of a minor peak, which was elucidated by NMR and HRMS as fenchyl-3,4-dihydro-5-hydroxy-2,7-dimethyl-8-(3 ''-methyl-2 ''-butenyl)-2-(4'-methyl-1',3'-pentadienyl)-2H-1-benzopyran-6-carboxylate, the same structure assigned to two other fenchyl esters described previously, pointing out a stereoisomeric relationship among them. Further NMR analysis revealed that it was actually a mixture of two compounds, whose absolute configurations were determined by VCD measurements. Although, almost no vibrational transitions could be assigned to the chiral chromane, the experimental VCD spectrum was largely opposite to that obtained for the average experimental VCD [(2S,1'''R,2'''R,4'''S + 2R,1'''R,2'''R,4'''S)/2] for fenchol derivatives. These results allowed us to assign the putative compounds as a racemic mixture of the chiral chromane esterified with the monoterpene (1S,2S,4R)fenchol, which had not been identified in our early work. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The deformation of a ring under axial compression is analyzed in order to estimate a favorable ring specimen geometry capable of limiting the influence of friction on the stress-strain curve obtained from SHPB tests. The analysis shows that the use of a ring specimen with a large inner diameter and a small radial thickness offers some advantages comparing with the traditional disk sample. In particular, it can improve the reliability of the test results for ductile materials in the presence of friction. Based on the deformation analysis of a ductile ring under compression, a correction coefficient is proposed to relate the actual material stress strain curve with the reading from the SHPB. It is shown using finite element simulation that the proposed correction can be used for a wide range of conventional ductile materials. Experimental results with steel alloys indicate that the correction procedure is an effective technique for an accurate measurement of the dynamic material strength response. (C) 2012 Elsevier Ltd. All rights reserved.