22 resultados para Test-retest reliability
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Resumo:
Little is known about the situational contexts in which individuals consume processed sources of dietary sugars. This study aimed to describe the situational contexts associated with the consumption of sweetened food and drink products in a Catholic Middle Eastern Canadian community. A two-stage exploratory sequential mixed-method design was employed with a rationale of triangulation. In stage 1 (n = 62), items and themes describing the situational contexts of sweetened food and drink product consumption were identified from semi-structured interviews and were used to develop the content for the Situational Context Instrument for Sweetened Product Consumption (SCISPC). Face validity, readability and cultural relevance of the instrument were assessed. In stage 2 (n = 192), a cross-sectional study was conducted and exploratory factor analysis was used to examine the structure of themes that emerged from the qualitative analysis as a means of furthering construct validation. The SCISPC reliability and predictive validity on the daily consumption of sweetened products were also assessed. In stage 1, six themes and 40-items describing the situational contexts of sweetened product consumption emerged from the qualitative analysis and were used to construct the first draft of the SCISPC. In stage 2, factor analysis enabled the clarification and/or expansion of the instrument's initial thematic structure. The revised SCISPC has seven factors and 31 items describing the situational contexts of sweetened product consumption. Initial validation of the instrument indicated it has excellent internal consistency and adequate test-retest reliability. Two factors of the SCISPC had predictive validity for the daily consumption of total sugar from sweetened products (Snacking and Energy demands) while the other factors (Socialization, Indulgence, Constraints, Visual Stimuli and Emotional needs) were rather associated to occasional consumption of these products.
Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
The objectives of the study were to translate and adapt the Subjective Handicap of Epilepsy (SHE) instrument to Brazilian Portuguese and to determine its psychometric properties for the evaluation of quality of life in patients with epilepsy. A sample of 448 adult patients with epilepsy with different clinical profiles (investigation, preoperative period, postoperative period, and drug treatment follow-up) was evaluated with the SHE and the Epilepsy Surgery Inventory (ESI-55). Exploratory factorial analysis demonstrated that four factors explained 60.47% of the variance and were sensitive to discriminate the different clinical groups, with the preoperative group having the poorest quality of life. Internal consistency ranged from 0.92 to 0.96, and concurrent validity with the ESI-55 was moderate/strong (0.32-0.70). Test-retest reliability was confirmed, with an ICC value of 0.54 (2 days), 0.91 (7 days), and 0.97 (30 days). The SHE had satisfactory psychometric qualities for use in the Brazilian population, similar to those of the original version. The instrument seems to be more adequate in psychometric terms for the postoperative and drug treatment follow-up groups, and its use should be encouraged. (c) 2012 Elsevier Inc. All rights reserved.
Resumo:
Abstract Background Most of the instruments available to measure the oral health-related quality of life (OHRQoL) in paediatric populations focus on older children, whereas parental reports are used for very young children. The scale of oral health outcomes for 5-year-old children (SOHO-5) assesses the OHRQoL of very young children through self-reports and parental proxy reports. We aimed to cross-culturally adapt the SOHO-5 to the Brazilian Portuguese language and to assess its reliability and validity. Findings We tested the quality of the cross-cultural adaptation in 2 pilot studies with 40 children aged 5–6 years and their parents. The measurement was tested for reliability and validity on 193 children that attended the paediatric dental screening program at the University of São Paulo. The children were also clinically examined for dental caries. The internal consistency was demonstrated by a Cronbach's alpha coefficient of 0.90 for the children’s self-reports and 0.77 for the parental proxy reports. The test-retest reliability results, which were based on repeated administrations on 159 children, were excellent; the intraclass correlation coefficient was 0.98 for parental and 0.92 for child reports. In general, the construct validity was satisfactory and demonstrated consistent and strong associations between the SOHO-5 and different subjective global ratings of oral health, perceived dental treatment need and overall well-being in both the parental and children’s versions (p < 0.001). The SOHO-5 was also able to clearly discriminate between children with and without a history of dental caries (mean scores: 5.8 and 1.1, respectively; p < 0.001). Conclusion The present study demonstrated that the SOHO-5 exhibits satisfactory psychometric properties and is applicable to 5- to 6-year-old children in Brazil.
Resumo:
Background Mindful-based interventions improve functioning and quality of life in fibromyalgia (FM) patients. The aim of the study is to perform a psychometric analysis of the Spanish version of the Mindful Attention Awareness Scale (MAAS) in a sample of patients diagnosed with FM. Methods The following measures were administered to 251 Spanish patients with FM: the Spanish version of MAAS, the Chronic Pain Acceptance Questionnaire, the Pain Catastrophising Scale, the Injustice Experience Questionnaire, the Psychological Inflexibility in Pain Scale, the Fibromyalgia Impact Questionnaire and the Euroqol. Factorial structure was analysed using Confirmatory Factor Analyses (CFA). Cronbach's α coefficient was calculated to examine internal consistency, and the intraclass correlation coefficient (ICC) was calculated to assess the test-retest reliability of the measures. Pearson’s correlation tests were run to evaluate univariate relationships between scores on the MAAS and criterion variables. Results The MAAS scores in our sample were low (M = 56.7; SD = 17.5). CFA confirmed a two-factor structure, with the following fit indices [sbX2 = 172.34 (p < 0.001), CFI = 0.95, GFI = 0.90, SRMR = 0.05, RMSEA = 0.06. MAAS was found to have high internal consistency (Cronbach’s α = 0.90) and adequate test-retest reliability at a 1–2 week interval (ICC = 0.90). It showed significant and expected correlations with the criterion measures with the exception of the Euroqol (Pearson = 0.15). Conclusion Psychometric properties of the Spanish version of the MAAS in patients with FM are adequate. The dimensionality of the MAAS found in this sample and directions for future research are discussed.
Resumo:
Backgroud: It has been shown that different symptoms or symptom combinations of neuropathic pain (NeP) may correspond to different mechanistic backgrounds and respond differently to treatment. The Neuropathic Pain Symptom Inventory (NPSI) is able to detect distinct clusters of symptoms (i.e. dimensions) with a putative common mechanistic background. The present study described the psychometric validation of the Portuguese version (PV) of the NPSI. Methods: Patients were seen in two consecutive visits, three to four weeks apart. They were asked to: (i) rate their mean pain intensity in the last 24 hours on an 11-point (0-10) numerical scale; (ii) complete the PV-NPSI; (iii) provide the list of pain medications and doses currently in use. VAS and Global Impression of Change (GIC) were filled out in the second visit. Results: PV-NPSI underwent test-retest reliability, factor analysis, analysis of sensitivity to changes between both visits. The PV-NPSI was reliable in this setting, with a good intra-class correlation for all items. The factorial analysis showed that the PV-NPSI inventory assessed different components of neuropathic pain. Five different factors were found. The PV-NPSI was adequate to evaluate patients with neuropathic pain and to detect clusters of NeP symptoms. Conclusions: The psychometric properties of the PV-NPSI rendered it adequate to evaluate patients with both central and peripheral neuropathic pain syndromes and to detect clusters of NeP symptoms.
Resumo:
OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.
Resumo:
Bertuzzi, R, Franchini, E, Tricoli, V, Lima-Silva, AE, Pires, FDO, Okuno, NM, and Kiss, MAPDM. Fit-climbing test: A field test for indoor rock climbing. J Strength Cond Res 26(6): 1558-1563, 2012-The aim of this study was to develop an indoor rock-climbing test on an artificial wall (Fit-climbing test). Thirteen climbers (elite group [EG] = 6; recreational group [RG] = 7) performed the following tests: (a) familiarization in the Fitclimbing test, (b) the Fit-climbing test, and (c) a retest to evaluate the Fit-climbing test's reliability. Gas exchange, blood lactate concentration, handgrip strength, and heart rate were measured during the test. Oxygen uptake during the Fit-climbing test was not different between groups (EG = 8.4 +/- 1.1 L; RG = 7.9 +/- 1.5 L, p > 0.05). The EG performance (120 +/- 7 movements) was statistically higher than the RG climbers' performance (78 +/- 13 movements) during the Fit-climbing test. Consequently, the oxygen cost per movement during the Fit-climbing test of the EG was significantly lower than that of the RG (p < 0.05). Handgrip strength was higher in the EG when compared with that in the RG in both pre-Fit- and post-Fit-climbing test (p < 0.05). There were no significant differences in any other variables analyzed during the Fit-climbing test (p > 0.05). Furthermore, the performance in the Fit-climbing test presented high reliability (intraclass correlation coefficient = 0.97). Therefore, the performance during the Fit-climbing test may be an alternative to evaluate rock climbers because of its specificity and relation to oxygen cost per movement during climbing.
Resumo:
Background and Study Aim: The grip strength endurance is important for Brazilian Jiu-Jitsu (BJJ). Thus, the aims of this study were: a) to test the reliability of two kimono grip strength tests named maximum static lift (MSL) and maximum number of repetitions (MNR) and b) to examine differences between elite and non-elite BJJ players in these tests. Material/Methods: Thirty BJJ players participated into two phases: "A" to test reliability and "B" to compare elite and non-elite. In phase A, twenty participants performed the MSL and, 15 min later, the MNR in two occasions with 24-h interval. In phase B, ten other BJJ practitioners (non-elite) and ten athletes (elite) performed the same tests. The intraclass correlation coefficient (ICC) two way fixed model (3,1), Bland-Altman plot and the limits of agreement were used to test reliability, correlation between the tests were evaluated by Pearson correlations and independent T test (P<0.05) was utilized to compare elite vs. non-elite. Results: The ICC was high for repeated measurements on different days of phase A (MSL: r=0.99 and MNR: r=0.97). Limits of agreement for time of suspension were -6.9 to 2.4-s, with a mean difference of -2.3 s (CI: -3.3 to -1.2-s), while for number of repetitions the limits of agreement were -2.9 to 2.3-rep, with a mean difference of -0.3-rep (CI: -0.9 to 0.3-rep). In phase B, elite presented better performance for both tests (P<0.05) compared to non-elite (56 +/- 10-s vs. 37 +/- 11-s in MSL and 15 +/- 4-rep vs. 8 +/- 3-rep in MNR). Moderate correlation were found between MSL and MNR for absolute values during test (r=0.475; p=0.034), and retest phases (r=0.489; p=0.029), while moderate and high correlations in the test (r=0.615; p=0.004) and retest phases (r=0.716; p=0.001) were found for relative values, respectively. Conclusions: These proposed tests are reliable and both static and dynamic grip strength endurance tests seem to differentiate BJJ athletes from different levels.
Resumo:
Este estudo teve como objetivo construir e conhecer os parâmetros psicométricos de um instrumento para análise da percepção visual de adultos. Para a construção da escala participaram 295 adultos saudáveis, sem déficits cognitivos ou perceptivo-visuais. Nesta etapa foi formulada uma escala tetrafatorial constituída por 20 itens que avaliam quatro dimensões referentes à percepção visual: constância da forma, figurafundo, posição e relação espacial. Para obter evidências de validade foi utilizada uma amostra de 183 voluntários com boa saúde física e mental e acuidade visual normal ou corrigida. Os dados obtidos relatam a existência de concordância interjuízes, adequação semântica e significância no teste-reteste do instrumento. Os coeficientes de fidedignidade variaram de 0,84 a 0,93. Os quatro fatores esperados foram encontrados, cada um contendo 5 itens, e juntos explicaram 57,52% da variância do constructo. O instrumento apresentou parâmetros psicométricos adequados, o que pode justificar sua utilidade em pesquisas básicas e na prática clínica.
Resumo:
Objective: to adapt and validate the Patient Expectations and Satisfaction with Prenatal Care instrument for use in Brazil. It contains 41 items divided into two dimensions: expectations and satisfaction. The adapted version was submitted to analysis for stability, convergent construct validity, and internal consistency (Cronbach’s alpha) for distinct groups and dimensions. Method: 119 pregnant women receiving prenatal care were interviewed and 26 of these women answered the instrument twice (retest). Internal consistency was appropriate (Cronbach’s alpha ≥ 0.70); test-retest presented strong correlation (r=0.82; p<0.001) for the domain expectations and moderate correlation (r=0.66; p<0.001) for the satisfaction domain. The analysis confirmed that the instrument’s adapted version is valid in the studied group. Results: there is strong evidence for the validity and reliability of the instrument’s adaptation. Conclusion: the instrument needs to be tested in groups of pregnant women with different social characteristics.
Resumo:
PURPOSE. To evaluate electrically evoked phosphene thresholds (EPTs) in healthy subjects and in patients with retinal disease and to assess repeatability and possible correlations with common ophthalmologic tests. METHODS. In all, 117 individuals participated: healthy subjects (n = 20) and patients with retinitis pigmentosa (RP, n = 30), Stargardt's disease (STG, n = 14), retinal artery occlusion (RAO, n = 20), nonarteritic anterior ischemic optic neuropathy (NAION, n = 16), and primary open-angle glaucoma (POAG, n = 17). EPTs were determined at 3, 6, 9, 20, 40, 60, and 80 Hz with 5+5-ms biphasic current pulses using DTL electrodes. Subjects were examined twice (test-retest range: 1-6 weeks). An empirical model was developed to describe the current-frequency relationship of EPTs. Visual acuity, visual field (kinetic + static), electrophysiology (RP, RAO, STG: Ganzfeld-electroretinography [ERG]/multifocal-ERG; POAG: pattern-ERG; NAION: VEP), slit-lamp biomicroscopy, fundus examination, and tonometry were assessed. RESULTS. EPTs varied between disease groups (20 Hz: healthy subjects: 0.062 +/- 0.038 mA; STG: 0.102 +/- 0.097 mA; POAG: 0.127 +/- 0.09 mA; NAION: 0.244 +/- 0.126 mA; RP: 0.371 +/- 0.223 mA; RAO: 0.988 +/- 1.142 mA). In all groups EPTs were lowest at 20 Hz. In patients with retinal diseases and across all frequencies EPTs were significantly higher than those in healthy subjects, except in STG at 20 Hz (P = 0.09) and 40 Hz (P = 0.17). Test-retest difference at 20 Hz was 0.006 mA in the healthy group and 0.003-0.04 mA in disease groups. CONCLUSIONS. Considering the fast, safe, and reliable practicability of EPT testing, this test might be used more often under clinical circumstances. Determination of EPTs could be potentially useful in elucidation of the progress of ophthalmologic diseases, either in addition to standard clinical assessment or under conditions in which these standard tests cannot be used meaningfully. (ClinicalTrials.gov number, NCT00804102.) (Invest Ophthalmol Vis Sci. 2012; 53: 7440-7448) DOI:10.1167/iovs.12-9612
Resumo:
The objective of this study was to perform the translation on and cultural adaptation of the Global Appraisal of Individual Needs - Initial instrument, and calculate its content validity index. This is a methodological study designed for the cultural adaptation of the instrument. The instrument was translated into Portuguese in two versions that originated the synthesis of the translations, which were then submitted to the evaluation of four judges, experts in the field of alcohol and other drugs. After the suggested changes were made, the instrument was back-translated and resubmitted to the judges and authors of the original instrument, resulting in the final version of the instrument, Avaliacao Global das Necessidades Individuais - Inicial. The content validity index of the instrument was 0.91, considered valid according to the literature. The instrument Avaliacao Global das Necessidades Individuais - Inicial was culturally adapted to the Portuguese language spoken in Brazil; however, it was not submitted to tests with the target population, which suggests further studies should be performed to test its reliability and validity.