56 resultados para Sintered samples

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Cobalt ferrite is a ferrimagnetic magnetostrictive ceramic that has potential application in magnetoelastic and magnetoelectric transducers. In this work, CoFe2O4 was obtained using a conventional ceramic method and Bi2O3 was used as additive in order to obtain liquid-phase sintered samples. Bi2O3 was added to the ferrite in amounts ranging from 0.25 mol% to 0.45 mol% and samples were sintered at 900 degrees C and 950 degrees C. It was observed the presence of Bi-containing particles in the microstructure of the sintered samples and the magnetostriction results indicated microstructural anisotropy. It was verified that it is possible to get dense cobalt ferrites, liquid-phase sintered, with relative densities higher than 90% and with magnetostriction values very close to samples sintered without additives.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recently, a new ternary phase was discovered in the Ti-Si-B system, located near the Ti6Si2B composition. The present study concerns the preparation of titanium alloys that contain such phase mixed with α-titanium and other intermetallic phases. High-purity powders were initially processed in a planetary ball-mill under argon atmosphere with Ti-18Si-6B and Ti-7.5Si-22.5B at. (%) initial compositions. Variation of parameters such as rotary speed, time, and ball diameters were adopted. The as-milled powders were pressureless sintered and hot pressed. Both the as-milled and sintered materials were characterized by X-ray diffraction, scanning electron microscopy and energy-dispersive spectrometry. Sintered samples have presented equilibrium structures formed mainly by the α-Ti+Ti6Si2B+Ti5Si3+TiB phases. Silicon and boron peaks disappear throughout the milling processes, as observed in the powder diffraction data. Furthermore, an iron contamination of up to 10 at. (%) is measured by X-ray spectroscopy analysis on some regions of the sintered samples. Density, hardness and tribological results for these two compositions are also presented here.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The structural and magnetic properties of a Fe-based alloy before and after sintering have been analyzed. X ray diffraction measurements confirm the deformation of the magnetic particles in the compacted samples. After sintering, hysteresis energy dissipation, remanence and intrinsic coercivity differ by less than 10% as porosity changes from 15 to 7%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology to analyze organochlorine pesticides (OCPs) in water samples has been accomplished by using headspace stir bar sorptive extraction (HS-SBSE). The bars were in house coated with a thick film of PDMS in order to properly work in the headspace mode. Sampling was done by a novel HS-SBSE system whereas the analysis was performed by capillary GC coupled mass spectrometric detection (HS-SBSE-GC-MS). The extraction optimization, using different experimental parameters has been established by a standard equilibrium time of 120 min at 85 degrees C. A mixture of ACN/toluene as back extraction solvent promoted a good performance to remove the OCPs sorbed in the bar. Reproducibility between 2.1 and 14.8% and linearity between 0.96 and 1.0 were obtained for pesticides spiked in a linear range between 5 and 17 ng/g in water samples during the bar evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency`s technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 mu mol L-1 with limit of detection of 2.80 mu mol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human T-cell lymphotropic virus type 1 (HTLV-1) is-an RNA virus responsible for diseases such as HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM/TSP) and adult T-cell leukemia/lymphoma (ATL). Cell-to-cell contact and Tax-induced clonal expansion of infected cells are the main modes of virus replication, making virus detection during the viremic stage difficult. Consequently, the proviral load is the current virologic marker for disease monitoring, but the mechanisms of progression have not been established yet. Thus, this study investigated the presence of virus in plasma from asymptomatic HTLV-1 carriers and from HAM/TSP patients. Real-time PCR was performed on DNA from 150 plasma samples; 12(8%) had detectable DNA amplification, including 6(4%) asymptomatic HTLV-1 carriers and 14(26%) HAM/TSP patients (p < 0.005). Of the 33 samples submitted for nested PCR, six (18%, p = 0.02) were positive for HTLV-1 RNA in the plasma. Additionally, 26 plasma samples were treated with DNAse enzyme to eliminate any DNA contamination before RNA extraction. Two of them (8%) showed amplification for HTLV-1 (p = 0.5). Therefore, this study described for the first time the detection of free HTLV-1 RNA in plasma from HTLV-1-infected subjects, regardless of their clinical status. Thus, HTLV-1 viral replication does occur in plasma, and other transmission pathways for HTLV-1 should be investigated further. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A fast method was optimized and validated in order to quantify amphetamine-type stimulants (amphetamine, AMP; methamphetamine, MAMP; fenproporex, FPX; 3,4-methylenedioxymethamphetamine, MDMA; and 3,4-methylenedioxyamphetamine, MDA) in human hair samples. The method was based in an initial procedure of decontamination of hair samples (50 mg) with dichloromethane, followed by alkaline hydrolysis and extraction of the amphetamines using hollow-fiber liquid-phase micro extraction (HF-LPME) in the three-phase mode. Gas chromatography-mass spectrometry (GC-MS) was used for identification and quantification of the analytes. The LoQs obtained for all amphetamines (around 0.05 ng/mg) were below the cut-off value (0.2 ng/mg) established by the Society of Hair Testing (SoHT). The method showed to be simple and precise. The intra-day and inter-day precisions were within 10.6% and 11.4%, respectively, with the use of only two deuteratecl internal standards (AMP-d5 and MDMA-d5). By using the weighted least squares linear regression (1/x(2)), the accuracy of the method was satisfied in the lower concentration levels (accuracy values better than 87%). Hair samples collected from six volunteers who reported regular use of amphetamines were submitted to the developed method. Drug detection was observed in all samples of the volunteers. (c) 2012 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fungal and mycotoxin contamination was investigated in field samples of nuts, shells and pods of the Brazil nut collected during different periods in Itacoatiara, State of Amazonas, Brazil: day 0, samples still on the tree: days 5, 10 and 15, samples in contact with soil for 5, 10 and 15 days, respectively. The most prevalent fungi were Aspergillus flavus in fruit pods and nuts and Fusarium spp. in shells. Penicillium spp. and A. flavus were isolated from soil, and Fusarium spp. and Penicillium spp. from air. Aflatoxins and cyclopiazonic acid were not detected in any of the samples analyzed. The high frequency of isolation of aflatoxigenic A. flavus strains from soil and Brazil nuts increases the chance of aflatoxin production in these substrates. These findings suggest a possible contamination before drying and indicate soil as the main source of fungal contamination of Brazil nuts. (c) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the ability of weevils to transmit Aspergillus flavus and Fusarium verticillioides fungal spores and the consequent production of mycotoxins. For this purpose, corn grain samples were stored in flasks connected to a hose to form a closed system (flasks A and B). Flasks A were inoculated with the following groups: group 1 (corn + weevil); group 2 (corn + A. flavus); group 3 (corn + A. flavus + weevil); group 4 (corn + F. verticillioides); group 5 (corn + E verticillioides + weevil), and group 6 (corn + A. flavus + E verticillioides + weevil). Flasks B contained sterile grains. The samples were incubated for 10, 20 and 30 days, posteriorly, weight, water activity, mycoflora, aflatoxins and fumonisins. The corn grain samples were also submitted to scanning electron microscopy. Our results showed that weevils could enhance corn grains contamination by these fungi, hence, could increase mycotoxins production. These findings demonstrate the importance of weevils as fungal vectors and the need for good manipulation and storage practices of grains. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polythiophene (PTh) phase electropolymerized on the stainless steel wire was evaluated as solid-phase microextraction (SPME), and analysis by liquid chromatography with spectrophotometric detection (LC-UV) for determination of new-generation antidepressants, selective serotonin reuptake inhibitors (SSRIs) (citalopram, paroxetine, fluoxetine and sertraline), in plasma samples. The influence of electropolymerization variables (scan rate, potential range and scan cycles) was evaluated on SPME performance. The SPME variables (extraction time, temperature, matrix pH, ionic strength and desorption procedure), as well as the influence of plasma proteins on sorption mechanisms were also evaluated. The SPME/LC-UV method developed for determination of antidepressants in plasma sample presented a linear range between the limit of quantification (LOQ, 200-250 ng mL(-1)) to 4000 ng mL(-1), and interday precision with coefficient of variation (CV) ranged from 11 to 15%. The proposed method can be a useful tool for the determination of antidepressants in human plasma samples in urgent toxicological analysis after the accidental or suicidal intake of higher doses of medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the occurrence of rotavirus infections in ostriches (Struthio camelus) reared in Northern Parana, Brazil. Fecal (n = 66) and serum (n = 182) samples from nine farms located in four different cities were analyzed by silver stained-polyacrylamide gel electrophoresis (ss-PAGE), RT-PCR assay, virus isolation, and counterimmunoelectroosmophoresis (CIE). Rotavirus group A seropositivity occurred in 5.49% (10/182) of serum samples of ostriches originated from two farms. Only 9.09% (6/66) of fecal samples from ostriches with diarrhea maintained in one farm were positive by ss-PAGE, RT-PCR, and virus isolation. The G (VP7) and P (VP4) genotypes of rotavirus wild strains isolated in cell culture were determined by multiplex-nested PCR. The genotyping identified two rotavirus strains: G6P[1] and G10P[1]. In three rotavirus strains it was only possible to identify the P type; one strain being P[1] and two strains that presented the combination of P[1] + P[7]. These findings might represent the first characterization of rotavirus in ostriches, and the finding of porcine and bovine-like rotavirus genotypes in ostriches might suggest virus reassortment and possible interspecies transmission. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A survey of Microsporum gypseum was conducted in soil samples in different geographical regions of Brazil. The isolation of dermatophyte from soil samples was performed by hair baiting technique and the species were identified by morphology studies. We analyzed 692 soil samples and the recuperating rate was 19.2%. The activities of keratinase and elastase were quantitatively performed in 138 samples. The sequencing of the ITS region of rDNA was performed in representatives samples. M. gypseum isolates showed significant quantitative differences in the expression of both keratinase and elastase, but no significant correlation was observed between these enzymes. The sequencing of the representative samples revealed the presence of two teleomorphic species of M. gypseum (Arthroderma gypseum and A. incurvatum). The enzymatic activities may play an important role in the pathogenicity and a probable adaptation of this fungus to the animal parasitism. Using the phenotypical and molecular analysis, the Microsporum identification and their teleomorphic states will provide a useful and reliable identification system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ayahuasca is a psychoactive plant beverage originally used by indigenous people throughout the Amazon Basin, long before its modern use by syncretic religious groups established in Brazil, the USA and European countries. The objective of this study was to develop a method for quantification of dimethyltryptamine and beta-carbolines in human plasma samples. Results: The analytes were extracted by means of C18 cartridges and injected into LC-MS/MS, operated in positive ion mode and multiple reaction monitoring. The LOQs obtained for all analytes were below 0.5 ng/ml. By using the weighted least squares linear regression, the accuracy of the analytical method was improved at the lower end of the calibration curve (from 0.5 to 100 ng/ml; r(2)> 0.98). Conclusion: The method proved to be simple, rapid and useful to estimate administered doses for further pharmacological and toxicological investigations of ayahuasca exposure.