10 resultados para Finite Difference Time Domain(FDTD)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This manuscript reports on the fabrication of plasmonic substrates using cathodic arc plasma ion implantation, in addition to their performance as SERS substrates. The technique allows for the incorporation of a wide layer of metallic nanoparticles into a polymer matrix, such as PMMA. The ability to pattern different structures using the PMMA matrix is one of the main advantages of the fabrication method. This opens up new possibilities for obtaining tailored substrates with enhanced performance for SERS and other surface-enhanced spectroscopies, as well as for exploring the basic physics of patterned metal nanostructures. The architecture of the SERS-active substrate was varied using three adsorption strategies for incorporating a laser dye (rhodamine): alongside the nanoparticles into the polymer matrix, during the polymer cure and within nanoholes lithographed on the polymer. As a proof-of-concept, we obtained the SERS spectra of rhodamine for the three types of substrates. The hypothesis of incorporation of rhodamine molecules into the polymer matrix during the cathodic arc plasma ion implantation was supported by FDTD (Finite-Difference Time-Domain) simulations. In the case of arrays of nanoholes, rhodamine molecules could be adsorbed directly on the gold surface, then yielding a well-resolved SERS spectrum for a small amount of analyte owing to the short-range interactions and the large longitudinal field component inside the nanoholes. The results shown here demonstrate that the approach based on ion implantation can be adapted to produce reproducible tailored substrates for SERS and other surface-enhanced spectroscopies.
Resumo:
The use of a low-cost benchtop time-domain NMR (TD-NMR) spectrometer to monitor copper electrodeposition in situ is presented. The measurements are based on the strong linear correlation between the concentration of paramagnetic ions and the transverse relaxation rates (R-2) of the solvent protons Two electrochemical NMR (EC-NMR) cells were constructed and applied to monitor the Cu2+ concentration during the electrodeposition reaction. The results show that TD-NMR relaxometry using the Carr-Purcell-Meiboom-Gill pulse sequence can be a very fast, simple, and efficient technique to monitor, in real time, the variation in the Cu2+ concentration during an electrodeposition reaction. This methodology can also be applied to monitor the electrodeposition of other paramagnetic ions, such as Ni2+ and Cr3+, which are commonly used in electroplating.
Resumo:
In the optimization or parametric analyses of risers, several configurations must be analyzed. It is laborious to perform time domain solutions for the dynamic analysis, since they are time-consuming tasks. So, frequency domain solutions appear to be a possible alternative, mainly in the early stages of a riser design. However, frequency domain analysis is linear and requires that nonlinear effects are treated. The aim of this paper is to present a possible way to treat some of these nonlinearities, using an iterative process together with an analytical correction, and compare the results of a frequency domain analysis with the those of a full nonlinear analysis. [DOI: 10.1115/1.4006149]
Resumo:
The technique of Time Domain Reflectometry (TDR) is applied for qualifying ethanol adulterated with water and / or methanol. We used the commercial TDR model VG400, which was originally developed for determining soil moisture, making this study an original approach for qualifying fuels. Several samples of alcohol with the addition of its main contaminants (water and methanol) were prepared and measured with the TDR sensor. The results indicate good response linearity, showing the TDR technique is a promising technique for fuel qualification
Resumo:
The numerical simulation of flows of highly elastic fluids has been the subject of intense research over the past decades with important industrial applications. Therefore, many efforts have been made to improve the convergence capabilities of the numerical methods employed to simulate viscoelastic fluid flows. An important contribution for the solution of the High-Weissenberg Number Problem has been presented by Fattal and Kupferman [J. Non-Newton. Fluid. Mech. 123 (2004) 281-285] who developed the matrix-logarithm of the conformation tensor technique, henceforth called log-conformation tensor. Its advantage is a better approximation of the large growth of the stress tensor that occur in some regions of the flow and it is doubly beneficial in that it ensures physically correct stress fields, allowing converged computations at high Weissenberg number flows. In this work we investigate the application of the log-conformation tensor to three-dimensional unsteady free surface flows. The log-conformation tensor formulation was applied to solve the Upper-Convected Maxwell (UCM) constitutive equation while the momentum equation was solved using a finite difference Marker-and-Cell type method. The resulting developed code is validated by comparing the log-conformation results with the analytic solution for fully developed pipe flows. To illustrate the stability of the log-conformation tensor approach in solving three-dimensional free surface flows, results from the simulation of the extrudate swell and jet buckling phenomena of UCM fluids at high Weissenberg numbers are presented. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.
Resumo:
The boundary layer over concave surfaces can be unstable due to centrifugal forces, giving rise to Goertler vortices. These vortices create two regions in the spanwise direction—the upwash and downwash regions. The downwash region is responsible for compressing the boundary layer toward the wall, increasing the heat transfer rate. The upwash region does the opposite. In the nonlinear development of the Goertler vortices, it can be observed that the upwash region becomes narrow and the spanwise–average heat transfer rate is higher than that for a Blasius boundary layer. This paper analyzes the influence of the spanwise wavelength of the Goertler the heat transfer. The equation is written in vorticity-velocity formulation. The time integration is done via a classical fourth-order Runge-Kutta method. The spatial derivatives are calculated using high-order compact finite difference and spectral methods. Three different wavelengths are analyzed. The results show that steady Goertler flow can increase the heat transfer rates to values close to the values of turbulence, without the existence of a secondary instability. The geometry (and computation domain) are presented
Resumo:
Purpose - The purpose of this paper is to develop an efficient numerical algorithm for the self-consistent solution of Schrodinger and Poisson equations in one-dimensional systems. The goal is to compute the charge-control and capacitance-voltage characteristics of quantum wire transistors. Design/methodology/approach - The paper presents a numerical formulation employing a non-uniform finite difference discretization scheme, in which the wavefunctions and electronic energy levels are obtained by solving the Schrodinger equation through the split-operator method while a relaxation method in the FTCS scheme ("Forward Time Centered Space") is used to solve the two-dimensional Poisson equation. Findings - The numerical model is validated by taking previously published results as a benchmark and then applying them to yield the charge-control characteristics and the capacitance-voltage relationship for a split-gate quantum wire device. Originality/value - The paper helps to fulfill the need for C-V models of quantum wire device. To do so, the authors implemented a straightforward calculation method for the two-dimensional electronic carrier density n(x,y). The formulation reduces the computational procedure to a much simpler problem, similar to the one-dimensional quantization case, significantly diminishing running time.
Resumo:
PURPOSE. We compared retinal nerve fiber layer (RNFL) and macular thickness measurements in patients with multiple sclerosis (MS) and neuromyelitis optica (NMO) with or without a history of optic neuritis, and in controls using Fourier-domain (FD) optical coherence tomography (OCT). METHODS. Patients with MS (n = 60), NMO (n = 33), longitudinal extensive transverse myelitis (LETM, n = 28) and healthy controls (n = 41) underwent ophthalmic examination, including automated perimetry, and FD-OCT RNFL and macular thickness measurements. Five groups of eyes were compared: MS with or without previous optic neuritis, NMO, LETM, and controls. Correlation between OCT and visual field (VF) findings was investigated. RESULTS. With regard to most parameters, RNFL and macular thickness measurements were significantly smaller in eyes of each group of patients compared to controls. MS eyes with optic neuritis did not differ significantly from MS eyes without optic neuritis, but measurements were smaller in NMO eyes than in all other groups. RNFL (but not macular thickness) measurements were significantly smaller in LETM eyes than in controls. While OCT abnormalities were correlated significantly with VF loss in NMO/LETM and MS, the correlation was much stronger in the former. CONCLUSIONS. Although FD-OCT RNFL and macular thickness measurements can reveal subclinical or optic neuritis-related abnormalities in NMO-spectrum and MS patients, abnormalities are predominant in the macula of MS patients and in RFNL measurements in NMO patients. The correlation between OCT and VF abnormalities was stronger in NMO than in MS, suggesting the two conditions differ regarding structural and functional damage. (ClinicalTrials.gov number, NCT01024985.) Invest Ophthalmol Vis Sci. 2012;53:3959-3966) DOI:10.1167/iovs.11-9324
Resumo:
This paper presents preliminary results to determine small displacements of a global positioning system (GPS) antenna fastened to a structure using only one L1 GPS receiver. Vibrations, periodic or not, are common in large structures, such as bridges, footbridges, tall buildings, and towers under dynamic loads. The behavior in time and frequency leads to structural analysis studies. The hypothesis of this article is that any large structure that presents vibrations in the centimeter-to-millimeter range can be monitored by phase measurements of a single L1 receiver with a high data rate, as long as the direction of the displacement is pointing to a particular satellite. Within this scenario, the carrier phase will be modulated by antenna displacement. During a period of a few dozen seconds, the relative displacement to the satellite, the satellite clock, and the atmospheric phase delays can be assumed as a polynomial time function. The residuals from a polynomial adjustment contain the phase modulation owing to small displacements, random noise, receiver clock short time instabilities, and multipath. The results showed that it is possible to detect displacements of centimeters in the phase data of a single satellite and millimeters in the difference between the phases of two satellites. After applying a periodic nonsinusoidal displacement of 10 m to the antenna, it is clearly recovered in the difference of the residuals. The time domain spectrum obtained by the fast Fourier transform (FFT) exhibited a defined peak of the third harmonic much more than the random noise using the proposed third-degree polynomial model. DOI: 10.1061/(ASCE)SU.1943-5428.0000070. (C) 2012 American Society of Civil Engineers.