Ethanol fuel analysis by time-domain reflectometry


Autoria(s): Rodrigues, Daniel B.R.; Peres, Henrique Estanislau Maldonado; Becari, Wesley
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

24/03/2014

24/03/2014

24/03/2014

Resumo

The technique of Time Domain Reflectometry (TDR) is applied for qualifying ethanol adulterated with water and / or methanol. We used the commercial TDR model VG400, which was originally developed for determining soil moisture, making this study an original approach for qualifying fuels. Several samples of alcohol with the addition of its main contaminants (water and methanol) were prepared and measured with the TDR sensor. The results indicate good response linearity, showing the TDR technique is a promising technique for fuel qualification

Identificador

#978-1-4799-1397-8

http://www.producao.usp.br/handle/BDPI/44260

http://www.imoc2013.org/IMOC2013/index.php#

Idioma(s)

eng

Publicador

Rio de Janeiro

Relação

SBMO/IEEE MTT-S International Microwave and Optoelectronics Conference

Direitos

openAccess

http://creativecommons.org/licenses/by-nc-nd/3.0/br/

IEEE

Palavras-Chave #Time-Domain Reflectometry #TDR #Fuel Qualification
Tipo

conferenceObject

Palestra