21 resultados para BARE

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new measurement of the B-11(p,alpha(0))Be-8 has been performed applying the Trojan horse method (THM) to the H-2(B-11,alpha Be-8(0))n quasi-free reaction induced at a laboratory energy of 27 MeV. The astrophysical S(E) factor has been extracted from similar to 600 keV down to zero energy by means of an improved data analysis technique and it has been compared with direct data available in the literature. The range investigated here overlaps with the energy region of the light element LiBeB stellar burning and with that of future aneutronic fusion power plants using the B-11+p fuel cycle. The new investigation described here confirms the preliminary results obtained in the recent TH works. The origin of the discrepancy between the direct estimate of the B-11(p,alpha(0))Be-8 S(E)-factor at zero energy and that from a previous THM investigation is quantitatively corroborated. The results obtained here support, within the experimental uncertainties, the low-energy S(E)-factor extrapolation and the value of the electron screening potential deduced from direct measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The preserved activity of immobilized biomolecules in layer-by-layer (LbL) films can be exploited in various applications. including biosensing. In this study, cholesterol oxidase (COX) layers were alternated with layers of poly(allylamine hydrochloride) (PAH) in LbL films whose morphology was investigated with atomic force microscopy (AFM). The adsorption kinetics of COX layers comprised two regimes, a fast, first-order kinetics process followed by a slow process fitted with a Johnson-Mehl-Avrami (JMA) function. with exponent similar to 2 characteristic of aggregates growing as disks. The concept based on the use of sensor arrays to increase sensitivity, widely employed in electronic tongues, was extended to biosensing with impedance spectroscopy measurements. Using three sensing units, made of LbL films of PAH/COX and PAHIPVS (polyvinyl sulfonic acid) and a bare gold interdigitated electrode, we were able to detect cholesterol in aqueous solutions down to the 10(-6) M level. This high sensitivity is attributed to the molecular-recognition interaction between COX and cholesterol, and opens the way for clinical tests to be made with low cost. fast experimental procedures. (C) 2008 Published by Elsevier B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 mu mol L-1 with limit of detection of 2.80 mu mol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flow of sediment from cropped land is the main pollutant of water sources in rural areas. Due to this fact, it is necessary to develop and implement technologies that will reduce water and sediment discharges. Accordingly, an experiment was conducted in the Department of Biosystems Engineering - ESALQ / USP, Piracicaba - SP with the objective to evaluate the effect of different soil cover (bean, grass and bare ground) and erosion control practices (wide base terraces and infiltration furrows in slopes (no practices to control erosion)) while measuring water losses in runoff. The statistical design adopted was randomized blocks in a 3x3 factorial scheme resulting in 9 treatments with 3 replicates (blocks). The period of rainfall data collection was December 6, 2007 to April 11, 2008. A 21.1 cm diameter rain gauge was installed in the experimental area. Terraces were the most efficient practices for reducing erosion losses in the treatments with infiltration furrows being better than the control treatment. Bean was more effective than grass in reducing erosion. Bare ground was the least efficient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The male of Potiicoara brasiliensis is reported for the first time with evidence of sexual dimorphism. Male diagnostic characters are described and compared with the other three species of Spelaeogriphidae. Males present differential morphology on both distal podomere articles of the antennula and antenna, an elongate and curved bare endopod on pleopod 2, a pair of short round penes on the sternum near the base of pereopod 7, and telson with dorsum almost smooth and apex straight. Material is sampled for the first time from karstic areas north of the species type-locality, Gruta Ricardo Franco near Corumba City, and Gruta do Curupira in the Araras Mountains. These new findings expand the distribution of the species over seven hundred kilometers. Comparisons between exemplars of both sexes are presented. A hypothesis on the distributional pattern of P. brasiliensis is introduced based on the geological history of Central-West Brazil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We investigated the relation between duration of dual antiplatelet therapy (DAPT) and clinical outcomes up to 12 months after Genous (TM) endothelial progenitor cell capturing R stent (TM) placement in patients from the e-HEALING registry. Background: Cessation of (DAPT) has been shown to be associated with the occurrence of stent thrombosis (ST). After Genous placement, 1 month of DAPT is recommended. Methods: Patients were analyzed according to continuation or discontinuation of DAPT at a 30-day and 6-month landmark, excluding patients with events before the landmark. Each landmark was a new baseline, and outcomes were followed up to 12 months after stenting. The main outcome for our current analysis was target vessel failure (TVF), defined as target vessel-related cardiac death or myocardial infarction and target vessel revascularization. Secondary outcomes included ST. (Un)adjusted hazard ratios (HR) for TVF were calculated with Cox regression. Results: No difference was observed in the incidence of TVF [HR: 1.03; 95% confidence intervals (CI): 0.651.65, P = 0.89] in patients continuing DAPT (n = 4,249) at 30 days versus patients stopped (n = 309), and HR: 0.82 (95% CI: 0.551.23, P = 0.34) in patients continuing DAPT (n = 2,654) at 6 months versus patients stopped [n = 1,408] DAPT). Furthermore, no differences were observed in ST. Even after addition of identified independent predictors for TVF, adjusted TVF hazards were comparable. Conclusions: In a post-hoc analysis of e-HEALING, duration of DAPT was not associated with the occurrence of the outcomes TVF or ST. The Genous stent may be an attractive treatment especially in patients at increased risk for (temporary) cessation of DAPT or bleeding. (C) 2011 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Current recommendations for antithrombotic therapy after drug-eluting stent (DES) implantation include prolonged dual antiplatelet therapy (DAPT) with aspirin and clopidogrel >= 12 months. However, the impact of such a regimen for all patients receiving any DES system remains unclear based on scientific evidence available to date. Also, several other shortcomings have been identified with prolonged DAPT, including bleeding complications, compliance, and cost. The second-generation Endeavor zotarolimus-eluting stent (E-ZES) has demonstrated efficacy and safety, despite short duration DAPT (3 months) in the majority of studies. Still, the safety and clinical impact of short-term DAPT with E-ZES in the real world is yet to be determined. Methods The OPTIMIZE trial is a large, prospective, multicenter, randomized (1: 1) non-inferiority clinical evaluation of short-term (3 months) vs long-term (12-months) DAPT in patients undergoing E-ZES implantation in daily clinical practice. Overall, 3,120 patients were enrolled at 33 clinical sites in Brazil. The primary composite endpoint is death (any cause), myocardial infarction, cerebral vascular accident, and major bleeding at 12-month clinical follow-up post-index procedure. Conclusions The OPTIMIZE clinical trial will determine the clinical implications of DAPT duration with the second generation E-ZES in real-world patients undergoing percutaneous coronary intervention. (Am Heart J 2012;164:810-816.e3.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Films of cellulose acetate butyrate (CAB) and carboxymethylcellulose acetate butyrate (CMCAB) were deposited from ethyl acetate solutions onto bare silicon wafers (Si/SiO2) or amino-terminated surfaces (APS) by means of equilibrium adsorption. All surfaces were characterized by means of ellipsometry, atomic force microscopy (AFM) and contact angle measurements. The presence of amino groups on the support surface favored the adsorption of CAB and CMCAB, inducing the orientation almost polar groups to the surface and the exposition of alkyl group to the air. Such molecular orientation caused increase of the dispersive component of surface energy (gamma(d)(s)) and decrease of the polar component of surface energy (gamma(p)(s)) of cellulose esters in comparison to those values determined for films deposited onto bare Si/SiO2 wafers. Adsorption behavior of jacalin or concanavalin A onto CAB and CMCAB films was also investigated. The adsorbed amounts of lectins were more pronounced on cellulose esters with high (gamma(p)(s)) and total surface energy (gamma(t)(s)) values. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical lead analyses of gunshot residues (GSRs) were performed using an acidic solution with a bare gold microelectrode in the presence of chloride ions. GSRs from four different guns (0.38 in. revolver, 12 caliber pump-action shotgun, 0.38 repeating rifle, and a 0.22 caliber semi-automatic rifle) and six different types of ammunition (CleanRange (R), normal, semi-jacketed, especial 24g (R), 3T (R), CBC (R), and Eley (R)) were analyzed. Results obtained with the proposed methodology were compared with those from an atomic absorption spectrometry analysis, and a paired Student's t-test indicated that there was no significant difference between them at the 95% confidence level. With this methodology, a detection limit of 1.7 nmol L-1 (3 sigma/slope), a linear range between 10 and 100 nmol L-1, and a relative standard deviation of 2.5% from 10 measurements were obtained. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the results of full-scale tests in beam-to-column connections for composite slim floor systems, including tests on Bare Steel connection and composite connection. The tested system consists of a concrete-filled composite column and a composite floor where an asymmetric steel beam is connected to a composite column by shear steel plates. Tests results previously obtained on partially encased composite beams were used to define the position of the headed studs in the slim floor system. Based on the obtained results of connections, the composite and Bare Steel connection behaved as semi-rigid and nominally pinned respectively. The tests results also indicated a significant contribution of the slim floor to the moment capacity of the connection. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A bare graphite-epoxy composite was evaluated as an electrode material in the determination of atenolol in natural water samples and pharmaceutical formulations for which the analyte was spiked. Using a DPV procedure, a linear response was observed in the 4.45-84.7 mu mol L-1 range with a LOD = 2.23 mu mol L-1, without need of surface renewal between successive runs, and recoveries between 92.5 and 107.5% for pharmaceutical formulations. The results obtained from the proposed procedure agreed with HPLC results within a 95% confidence level. During the determination of atenolol in water samples, recoveries between 96.1 and 102.6% were found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vortex-induced motion (VIM) is a specific way for naming the vortex-induced vibration (VIV) acting on floating units. The VIM phenomenon can occur in monocolumn production, storage and offloading system (MPSO) and spar platforms, structures presenting aspect ratio lower than 4 and unity mass ratio, i.e., structural mass equal to the displaced fluid mass. These platforms can experience motion amplitudes of approximately their characteristic diameters, and therefore, the fatigue life of mooring lines and risers can be greatly affected. Two degrees-of-freedom VIV model tests based on cylinders with low aspect ratio and small mass ratio have been carried out at the recirculating water channel facility available at NDF-EPUSP in order to better understand this hydro-elastic phenomenon. The tests have considered three circular cylinders of mass ratio equal to one and different aspect ratios, respectively L/D = 1.0, 1.7, and 2.0, as well as a fourth cylinder of mass ratio equal to 2.62 and aspect ratio of 2.0. The Reynolds number covered the range from 10 000 to 50 000, corresponding to reduced velocities from 1 to approximately 12. The results of amplitude and frequency in the transverse and in-line directions were analyzed by means of the Hilbert-Huang transform method (HHT) and then compared to those obtained from works found in the literature. The comparisons have shown similar maxima amplitudes for all aspect ratios and small mass ratio, featuring a decrease as the aspect ratio decreases. Moreover, some changes in the Strouhal number have been indirectly observed as a consequence of the decrease in the aspect ratio. In conclusion, it is shown that comparing results of small-scale platforms with those from bare cylinders, all of them presenting low aspect ratio and small mass ratio, the laboratory experiments may well be used in practical investigation, including those concerning the VIM phenomenon acting on platforms. [DOI: 10.1115/1.4006755]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The immobilization of the glucose/mannose-binding lectin from Concanavalia ensiformis seeds (ConA) onto a monolayer made of a galactomannan extracted from Leucaena leucocephala seeds (GML), which was adsorbed onto - amino-terminated surfaces, was investigated by means of ellipsometry and atomic force microscopy. The mean thickness of GML monolayer, which polysaccharide consists of linear 1 -> 4-linked beta-D-mannopyranosil units partially substituted at C-6 by alpha-D-galactopyranosyl units, amounted to (1.5 +/- 0.2) nm. ConA molecules adsorbed onto GML surfaces forming (2.0 +/- 0.5) nm thick layers. However, in the presence of mannose the adsorption failed, indicating that ConA binding sites were blocked by mannose and were no longer available for mannose units present in the GML backbone. The GML film was also used as support for the adsorption of three serotypes of dengue virus particles (DENV-1, DENV-2 and DENV-3), where DENV-2 formed the thickest film (4 +/- 2) nm. The adsorbed layer of DENV-2 onto ConA-covered GML surfaces presented mean thickness values similar to that determined for DENV-2 onto bare GML surfaces. The addition of free mannose units prevented DENV-2 adsorption onto ConA-covered GML films by similar to 50%, suggesting competition between virus and mannose for ConA binding sites. This finding suggests that if ConA is also adsorbed to GML surface and its binding site is blocked by free mannose, virus particles are able to recognized GML mannose unities substituted by galactose. interactions between polysaccharides thin films, proteins, and viruses are of great relevance since they can provide basis for the development of biotechnological devices. These results indicate that GML is a potential polysaccharide for biomaterials development, as those could involve interactions between ConA in immune system and viruses. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate an innovative technique for intrastromal air injection to achieve deep anterior lamellar keratoplasty (DALK) with bare Descemet membrane (DM). Thirty-four eyes with anterior corneal pathology, including 27 with keratoconus, underwent DALK. After 400 mm trephination with a suction trephine, ultrasound pachymetry was performed 0.8 mm internally from the trephination groove in the 11 to 1 o'clock position. In this area, a 2-mm incision was created, parallel to the groove, with a micrometer diamond knife calibrated to 90% depth of the thinnest measurement. A cannula was inserted through the incision and 0.5 mL of air was injected to dissect the DM from the stroma. After peripheral paracentesis, anterior keratectomy was carried out to bare the DM. A 0.25-mm oversized graft was sutured in place. Overall, 94.1% of eyes achieved DALK. Bare DM was achieved in 30 eyes, and a pre-DM dissection was performed in 2 eyes. Air injection was successful in detaching the DM (achieving the big bubble) in 88.2% of the eyes. In keratoconus eyes, the rate was 88.9%. All cases but one required a single air injection to achieve DM detachment. Microperforations occurred in 5 cases: 3 during manual layer-by-layer dissection after air injection failed to detach the DM, 1 during removal of the residual stroma after big-bubble formation, and 1 during the diamond knife incision. Two cases (5.9%) were converted to penetrating keratoplasty because of macroperforations. The technique was reproducible, safe, and highly effective in promoting DALK with bare DM.