2 resultados para 382.98

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antimicrobial activity of hemoglobin fragments (hemocidins) has been reported in a variety of models. The cattle tick Rhipicephalus (Boophilus) microplus is a blood sucking arthropod from where the first in vivo-generated hemocidin was characterized (Hb 33-61). In the present work we identified a novel antimicrobial peptide from the midgut of fully engorged R. (B.) microplus females, which comprises the amino acids 98-114 of the alpha subunit of bovine hemoglobin, and was designated Hb 98-114. This peptide was active against several yeast and filamentous fungi, although no activity was detected against bacteria up to 50 mu M of the synthetic peptide. Hb 98-114 was capable of permeabilizing Candida albicans cell membrane and had a fungicidal effect against this yeast. Circulardichroism (CD) and nuclear magnetic resonance (NMR) experiments showed that Hb 98-114 has a random conformation in aqueous solution but switches to an alpha-helical conformation in the presence of sodium dodecyl sulfate (SDS). This alpha helix adopts an amphipathic structure which may be the mechanism of cell membrane permeabilization. Importantly, Hb 98-114 may play an important role in defending the tick midgut against fungal pathogens and is the first hemocidin with specific antifungal activity to be characterized. (C) 2012 Elsevier Inc. All rights reserved.