The Endothelial Sample Size Analysis in Corneal Specular Microscopy Clinical Examinations


Autoria(s): Abib, Fernando C.; Holzchuh, Ricardo; Schaefer, Artur; Schaefer, Tania; Godois, Ronialci
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

30/09/2013

30/09/2013

2012

Resumo

Purpose: To evaluate endothelial cell sample size and statistical error in corneal specular microscopy (CSM) examinations. Methods: One hundred twenty examinations were conducted with 4 types of corneal specular microscopes: 30 with each BioOptics, CSO, Konan, and Topcon corneal specular microscopes. All endothelial image data were analyzed by respective instrument software and also by the Cells Analyzer software with a method developed in our lab(US Patent). A reliability degree (RD) of 95% and a relative error (RE) of 0.05 were used as cut-off values to analyze images of the counted endothelial cells called samples. The sample size mean was the number of cells evaluated on the images obtained with each device. Only examinations with RE<0.05 were considered statistically correct and suitable for comparisons with future examinations. The Cells Analyzer software was used to calculate the RE and customized sample size for all examinations. Results: Bio-Optics: sample size, 97 +/- 22 cells; RE, 6.52 +/- 0.86; only 10% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 162 +/- 34 cells. CSO: sample size, 110 +/- 20 cells; RE, 5.98 +/- 0.98; only 16.6% of the examinations had sufficient endothelial cell quantity (RE<0.05); customized sample size, 157 +/- 45 cells. Konan: sample size, 80 +/- 27 cells; RE, 10.6 +/- 3.67; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 336 +/- 131 cells. Topcon: sample size, 87 +/- 17 cells; RE, 10.1 +/- 2.52; none of the examinations had sufficient endothelial cell quantity (RE>0.05); customized sample size, 382 +/- 159 cells. Conclusions: A very high number of CSM examinations had sample errors based on Cells Analyzer software. The endothelial sample size (examinations) needs to include more cells to be reliable and reproducible. The Cells Analyzer tutorial routine will be useful for CSM examination reliability and reproducibility.

Identificador

CORNEA, PHILADELPHIA, v. 31, n. 5, pp. 546-550, MAY, 2012

0277-3740

http://www.producao.usp.br/handle/BDPI/33853

10.1097/ICO.0b013e3181cc7961

http://dx.doi.org/10.1097/ICO.0b013e3181cc7961

Idioma(s)

eng

Publicador

LIPPINCOTT WILLIAMS & WILKINS

PHILADELPHIA

Relação

CORNEA

Direitos

restrictedAccess

Copyright LIPPINCOTT WILLIAMS & WILKINS

Palavras-Chave #CORNEA #ENDOTHELIUM #SPECULAR MICROSCOPY #SPECULAR MICROSCOPE #ANALYSIS #SAMPLE #SAMPLE ERROR #OPHTHALMOLOGY
Tipo

article

original article

publishedVersion