31 resultados para Diagnostic Errors
Resumo:
This paper introduces a skewed log-Birnbaum-Saunders regression model based on the skewed sinh-normal distribution proposed by Leiva et al. [A skewed sinh-normal distribution and its properties and application to air pollution, Comm. Statist. Theory Methods 39 (2010), pp. 426-443]. Some influence methods, such as the local influence and generalized leverage, are presented. Additionally, we derived the normal curvatures of local influence under some perturbation schemes. An empirical application to a real data set is presented in order to illustrate the usefulness of the proposed model.
Resumo:
Nowadays, the zinc oxide surge arresters (ZnO) are widely used in power systems, however, a large number of silicon carbide surge arresters (SiC) are still in service in the utilities. On the other hand, it is not possible to replace all SiC surge arresters in a short time period, being necessary to review the maintenance program taking into account the surge arresters that are more degraded. In this context, a research project was established between the University of Sao Paulo and the electrical utility CTEEP, aiming the investigation of its SiC surge arresters. This work shows that the leakage current measurement, a diagnostic method for the ZnO surge arresters, can provide useful information related to the condition of the SiC surge arresters. Analysis of the amplitude and distortion of the leakage current, also considering thermovision measurements, resulted in better evaluation of the SiC surge arresters.
Resumo:
PURPOSE: To evalulate the applicability of the Revised Diagnostic Criteria for Vogt-Koyanagi-Harada (VKH) disease to Brazilian patients and to verify the association between different disease categories, clinical parameters, and the presence of HLA-DRB1*0405. DESIGN: A retrospective observational case series. METHODS: Medical charts of 67 patients (10 to 64 years in age; 12 men and 55 women), from the Uveitis Service, Hospital das Clinicas, University of Sao Paulo School of Medicine (HCFMUSP), Sao Paulo, Brazil were reviewed. Patients, previously diagnosed with VKH disease using criteria proposed by the American Uveitis Society, underwent retrospective classification based on the Revised Diagnostic Criteria. The degree of concordance was assessed. At presentation, 46 patients (69%) were in the early phase. In this group, the mean time from disease onset to treatment was 15 days (range, one to 30 days). Forty-eight patients (72%) were typed for HLA-DRB1*0405 by polymerase chain reaction-sequence specific primer and polymerase chain reaction,sequence, specific oligonucleotides primer. Disease categories, phase at initial presentation, and ocular complications were analyzed. RESULTS: There was a 100% of concordance between the two criteria. Disease was classified as complete in 10 patients (15%), incomplete in 37 patients (55%), and probable in 20 patients (30%). In each group, respectively, 90%, 76%, and 45% were in the early phase at presentation (P = .017). There was no association between disease categories, the presence of HLA-DRB1*0405, and clinical parameters. CONCLUSION. The Revised Diagnostic Criteria proved useful for diagnosis of VKH disease in Brazilian patients. The present retrospective study did not find any association between disease category and severity parameters. To better understand the relevance of disease categories, a minimum follow-up period to categorize patients should be included in future prospective studies. (Am J Ophthalmol 2009;147:339-345. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Across the Americas and the Caribbean, nearly 561,000 slide-confirmed malaria infections were reported officially in 2008. The nine Amazonian countries accounted for 89% of these infections; Brazil and Peru alone contributed 56% and 7% of them, respectively. Local populations of the relatively neglected parasite Plasmodium vivax, which currently accounts for 77% of the regional malaria burden, are extremely diverse genetically and geographically structured. At a time when malaria elimination is placed on the public health agenda of several endemic countries, it remains unclear why malaria proved so difficult to control in areas of relatively low levels of transmission such as the Amazon Basin. We hypothesize that asymptomatic parasite carriage and massive environmental changes that affect vector abundance and behavior are major contributors to malaria transmission in epidemiologically diverse areas across the Amazon Basin. Here we review available data supporting this hypothesis and discuss their implications for current and future malaria intervention policies in the region. Given that locally generated scientific evidence is urgently required to support malaria control interventions in Amazonia, we briefly describe the aims of our current field-oriented malaria research in rural villages and gold-mining enclaves in Peru and a recently opened agricultural settlement in Brazil. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Activin A is a growth factor, produced by the endometrium, whose actions are modulated by the binding protein follistatin. Both proteins are detectable in the peripheral serum and their concentrations may be increased in women with endometriosis. The present study was designed to evaluate whether serum levels of activin A and follistatin are altered, and therefore have a potential diagnostic value, in women with peritoneal, ovarian and deep infiltrating endometriosis. We performed a multicenter controlled study evaluating simultaneously serum activin A and follistatin concentrations in women with and without endometriosis. Women with endometriosis (n 139) were subdivided into three groups: peritoneal endometriosis (n 28); ovarian endometrioma (n 61) and deep infiltrating endometriosis (n 50). The control group (n 75) consisted of healthy women with regular menstrual cycles. Blood samples were collected from a peripheral vein and assayed for activin A and follistatin using commercially available enzyme immunoassay kits. The ovarian endometrioma group had serum activin A levels significantly higher than healthy controls (0.22 0.01 ng/ml versus 0.17 0.01 ng/ml, P 0.01). None of the endometriosis groups had serum follistatin levels which were significantly altered compared with healthy controls; however, levels found in the endometrioma group (2.34 0.32 ng/ml) were higher than that in the deep endometriosis group (1.50 0.17 ng/ml, P 0.05). The area under the receiver operating characteristic curve of activin A was 0.700 (95 confidence interval: 0.6050.794), while that of follistatin was 0.620 (95 confidence interval: 0.5100.730) for the diagnosis of ovarian endometrioma. The combination of both markers into a duo marker index did not improve significantly their diagnostic accuracy. The present study demonstrated that serum activin A and follistatin are not significantly altered in peritoneal or deep infiltrating endometriosis and have limited diagnostic accuracy in the diagnosis of ovarian endometrioma.
Resumo:
This article describes the development and evaluation of software that verifies the accuracy of diagnoses made by nursing students. The software was based on a model that uses fuzzy logic concepts, including PERL, the MySQL database for Internet accessibility, and the NANDA-I 2007-2008 classification system. The software was evaluated in terms of its technical quality and usability through specific instruments. The activity proposed in the software involves four stages in which students establish the relationship values between nursing diagnoses, defining characteristics/risk factors and clinical cases. The relationship values determined by students are compared to those of specialists, generating performance scores for the students. In the evaluation, the software demonstrated satisfactory outcomes regarding the technical quality and, according to the students, helped in their learning and may become an educational tool to teach the process of nursing diagnosis.
Resumo:
We address the problem of selecting the best linear unbiased predictor (BLUP) of the latent value (e.g., serum glucose fasting level) of sample subjects with heteroskedastic measurement errors. Using a simple example, we compare the usual mixed model BLUP to a similar predictor based on a mixed model framed in a finite population (FPMM) setup with two sources of variability, the first of which corresponds to simple random sampling and the second, to heteroskedastic measurement errors. Under this last approach, we show that when measurement errors are subject-specific, the BLUP shrinkage constants are based on a pooled measurement error variance as opposed to the individual ones generally considered for the usual mixed model BLUP. In contrast, when the heteroskedastic measurement errors are measurement condition-specific, the FPMM BLUP involves different shrinkage constants. We also show that in this setup, when measurement errors are subject-specific, the usual mixed model predictor is biased but has a smaller mean squared error than the FPMM BLUP which points to some difficulties in the interpretation of such predictors. (C) 2011 Elsevier By. All rights reserved.
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
The main goal of this article is to consider influence assessment in models with error-prone observations and variances of the measurement errors changing across observations. The techniques enable to identify potential influential elements and also to quantify the effects of perturbations in these elements on some results of interest. The approach is illustrated with data from the WHO MONICA Project on cardiovascular disease.
Resumo:
A recent review of the homology concept in cladistics is critiqued in light of the historical literature. Homology as a notion relevant to the recognition of clades remains equivalent to synapomorphy. Some symplesiomorphies are homologies inasmuch as they represent synapomorphies of more inclusive taxa; others are complementary character states that do not imply any shared evolutionary history among the taxa that exhibit the state. Undirected character-state change (as characters optimized on an unrooted tree) is a necessary but not sufficient test of homology, because the addition of a root may alter parsimonious reconstructions. Primary and secondary homology are defended as realistic representations of discovery procedures in comparative biology, recognizable even in Direct Optimization. The epistemological relationship between homology as evidence and common ancestry as explanation is again emphasized. An alternative definition of homology is proposed. (c) The Willi Hennig Society 2012.
Resumo:
Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.
Resumo:
Changepoint regression models have originally been developed in connection with applications in quality control, where a change from the in-control to the out-of-control state has to be detected based on the avaliable random observations. Up to now various changepoint models have been suggested for differents applications like reliability, econometrics or medicine. In many practical situations the covariate cannot be measured precisely and an alternative model are the errors in variable regression models. In this paper we study the regression model with errors in variables with changepoint from a Bayesian approach. From the simulation study we found that the proposed procedure produces estimates suitable for the changepoint and all other model parameters.
Resumo:
Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.
Resumo:
We propose a new general Bayesian latent class model for evaluation of the performance of multiple diagnostic tests in situations in which no gold standard test exists based on a computationally intensive approach. The modeling represents an interesting and suitable alternative to models with complex structures that involve the general case of several conditionally independent diagnostic tests, covariates, and strata with different disease prevalences. The technique of stratifying the population according to different disease prevalence rates does not add further marked complexity to the modeling, but it makes the model more flexible and interpretable. To illustrate the general model proposed, we evaluate the performance of six diagnostic screening tests for Chagas disease considering some epidemiological variables. Serology at the time of donation (negative, positive, inconclusive) was considered as a factor of stratification in the model. The general model with stratification of the population performed better in comparison with its concurrents without stratification. The group formed by the testing laboratory Biomanguinhos FIOCRUZ-kit (c-ELISA and rec-ELISA) is the best option in the confirmation process by presenting false-negative rate of 0.0002% from the serial scheme. We are 100% sure that the donor is healthy when these two tests have negative results and he is chagasic when they have positive results.
Resumo:
Robust analysis of vector fields has been established as an important tool for deriving insights from the complex systems these fields model. Traditional analysis and visualization techniques rely primarily on computing streamlines through numerical integration. The inherent numerical errors of such approaches are usually ignored, leading to inconsistencies that cause unreliable visualizations and can ultimately prevent in-depth analysis. We propose a new representation for vector fields on surfaces that replaces numerical integration through triangles with maps from the triangle boundaries to themselves. This representation, called edge maps, permits a concise description of flow behaviors and is equivalent to computing all possible streamlines at a user defined error threshold. Independent of this error streamlines computed using edge maps are guaranteed to be consistent up to floating point precision, enabling the stable extraction of features such as the topological skeleton. Furthermore, our representation explicitly stores spatial and temporal errors which we use to produce more informative visualizations. This work describes the construction of edge maps, the error quantification, and a refinement procedure to adhere to a user defined error bound. Finally, we introduce new visualizations using the additional information provided by edge maps to indicate the uncertainty involved in computing streamlines and topological structures.