98 resultados para offset implant placement

em Queensland University of Technology - ePrints Archive


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This article reviews the literature on the outcome of flapless surgery for dental implants in the posterior maxilla. The literature search was carried out in using the keywords: flapless, dental implants and maxilla. A hand search and Medline search were carried out on studies published between 1971 and 2011. The authors included research involving a minimum of 15 dental implants with a followup period of 1 year, an outcome measurement of implant survival, but excluded studies involving multiple simultaneous interventions, and studies with missing data. The Cochrane approach for cohort studies and Oxford Centre for Evidence- Based Medicine were applied. Of the 56 published papers selected, 14 papers on the flapless technique showed high overall implant survival rates. The prospective studies yielded 97.01% (95% CI: 90.72–99.0) while retrospective studies or case series illustrated 95.08% (95% CI: 91.0–97.93) survival. The average of intraoperative complications was 6.55% using the flapless procedure. The limited data obtained showed that flapless surgery in posterior maxilla areas could be a viable and predictable treatment method for implant placement. Flapless surgery tends to be more applicable in this area of the mouth. Further long-term clinical controlled studies are needed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Adolescent idiopathic scoliosis (AIS) is a complex 3D deformity of the spine, which may require surgical correction in severe cases. Computer models of the spine provide a potentially powerful tool to virtually ‘test’ various surgical scenarios prior to surgery. Using patient-specific computer models of seven AIS patients who had undergone a single rod anterior procedure, we have recently found that the majority of the deformity correction occurs at the apical joint or the joint immediately cephalic to the apex. In the current paper, we investigate the biomechanics of the apical joint for these patients using clinically measured intra-operative compressive forces applied during implant placement. The aim of this study is to determine a relationship between the compressive joint force applied intra-operatively and the achievable deformity correction at the apical joint.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Use of patient-specific computer models as a pre-operative planning tool permits predictions of the likely deformity correction and allows a more detailed investigation of the biomechanical influence of different surgical procedures on the scoliotic spinal anatomy. In this paper, patient-specific computer models are used of adolescent idiopathic scoliosis patients who underwent a single rod anterior procedure at the Mater Children’s Hospital in Brisbane, to predict deformity correction and to investigate the change in biomechanics of the scoliotic spine due to surgical compressive forces applied during implant placement.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The project applied analytical facilities to characterize the composition and mechanical properties of osteoporosis in maxillary bone using an ovariectomized rat model. It was found that osteoporotic jaw bone contained different amount of trace elements in comparison with the normal bone, which plays a significant role in bone quality. The knowledge generated from the study will assist the treatment of jaw bone fracture and dental implant placement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The accuracy of marker placement on palpable surface anatomical landmarks is an important consideration in biomechanics. Although marker placement reliability has been studied in some depth, it remains unclear whether or not the markers are accurately positioned over the intended landmark in order to define the static position and orientation of the segment. A novel method using commonly available X-ray imaging was developed to identify the accuracy of markers placed on the shoe surface by palpating landmarks through the shoe. An anterior–posterior and lateral–medial X-ray was taken on 24 participants with a newly developed marker set applied to both the skin and shoe. The vector magnitude of both skin- and shoe-mounted markers from the anatomical landmark was calculated, as well as the mean marker offset between skin- and shoe-mounted markers. The accuracy of placing markers on the shoe relative to the skin-mounted markers, accounting for shoe thickness, was less than 5mm for all markers studied. Further, when using the developed guidelines provided in this study, the method was deemed reliable (Intra-rater ICCs¼0.50–0.92). In conclusion, the method proposed here can reliably assess marker placement accuracy on the shoe surface relative to chosen anatomical landmarks beneath the skin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Exeter stems vary in length from 90 to 150 mm. The shorter stems generally have lower offsets. The purpose of this study was to determine if length of stem, with fixed offset, affected rotational stability. Mechanical testing was carried out on 10 implant-cement constructs with 2 loading profiles, rising from chair and stair climbing, at different simulated implant lengths using purpose-built apparatus. This paper presents a mechanism for clinically observed rotational stability and explains the mechanical characteristics required for rotational stability in Exeter femoral stems. © 2012.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to identify retrospectively the predictors of implant survival when the flapless protocol was used in two private dental practices. Materials and Methods: The collected data were initially computer searched to identify the patients; later, a hand search of patient records was carried out to identify all flapless implants consecutively inserted over the last 10 years. The demographic information gathered on statistical predictors included age, sex, periodontal and peri-implantitis status, smoking, details of implants inserted, implant locations, placement time after extraction, use of simultaneous guided hard and soft tissue regeneration procedures, loading protocols, type of prosthesis, and treatment outcomes (implant survival and complications). Excluded were any implants that required flaps or simultaneous guided hard and soft tissue regeneration procedures, and implants narrower than 3.25 mm. Results: A total of 1,241 implants had been placed in 472 patients. Life table analysis indicated cumulative 5-year and 10-year implant survival rates of 97.9% and 96.5%, respectively. Most of the failed implants occurred in the posterior maxilla (54%) in type 4 bone (74.0%), and 55.0% of failed implants had been placed in smokers. Conclusion: Flapless dental implant surgery can yield an implant survival rate comparable to that reported in other studies using traditional flap techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the effectiveness of virtual product placement as a marketing tool by examining the relationship between brand recall and recognition and virtual product placement. It also aims to address a gap in the existing academic literature by focusing on the impact of product placement on recall and recognition of new brands. The growing importance of product placement is discussed and a review of previous research on product placement and virtual product placement is provided. The research methodology used to study the recall and recognition effects of virtual product placement are described and key findings presented. Finally, implications are discussed and recommendations for future research provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In some Queensland universities, Information Systems academics have moved out of Business Faculties. This study uses a pilot SWOT analysis to examine the ramifications of Information Systems academics being located within or outside of the Business Faculty. The analysis provides a useful basis for decision makers in the School studied, to exploit opportunities and minimise external threats. For Information Systems academics contemplating administrative relocation of their group, the study also offers useful insights. The study presages a series of further SWOT analyses to provide a range of perspectives on the relative merits of having Information Systems academics administratively located inside versus outside Business faculties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Growth rods are commonly used for the treatment of scoliosis in the immature spine. Many variations have been proposed but breakage of implants is a common problem. Growth rod insertion commonly involves large exposures at initial insertion followed by multiple smaller procedures for lengthening. We present our early experiences using a percutaneous technique of insertion of a new titanium mobile bearing implant (Medtronic Inc). The implant allows some rotatory motion in the middle of the construct thus reducing construct stresses and thus possibly reducing rod breakage risk. Based on this small initial series with 12 months follow-up, percutaneous insertion of growth rods using the new implant is a safe and reliable technique although the infection rate in our sample was of note. This may be related to the titanium wear and inflammation seen in the soft tissues at time of operation and visualised on histology. No implants have required removal due to infection, and all infections were treated with debridement at next lengthening and suppressive antibiotics. Propionibacterium is one of the commonest infections seen with spinal implants and sometimes does not respond to simple antibiotic suppression. The technique allows preservation of the soft tissues until definitive fusion is needed and may lead to a decrease in hospital stay. The implant is low profile and seems to offer advantages over other systems on the market. Further follow up is needed to look at longer term outcomes with this new implant type.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Practice placement education has been recognised as an integral and critical component of the training of occupational therapy students. Although there is an extensive body of literature on clinical education and traditional practice placement education models, there has been limited research on alternative placements.-------- This paper reviews the literature on various practice placement education models and presents a contemporary view on how it is currently delivered. The literature is examined with a particular focus on the increasing range of practice placement education opportunities, such as project and role-emerging placements. The drivers for non-traditional practice placement education include shortages of traditional placement options, health reform and changing work practices, potential for role development and influence on practice choice. The benefits and challenges of non-traditional practice placement education are discussed, including supervision issues, student evaluation, professional and personal development and the opportunity to practise clinical skills.--------- Further research is recommended to investigate occupational therapy graduates' perceptions of role-emerging and project placements in order to identify the benefits or otherwise of these placements and to contribute to the limited body of knowledge of emerging education opportunities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite its growth and prominence, product placement is generally under-researched and this is even more apparent in the area of placement in video gaming. This paper presents exploratory focus group research into this practice. Findings indicate that the introductory footage to a game provides placement opportunities with the highest level of recall, while peripheral non-action is the worst. Interestingly, recall also appears to be higher for individual brands as opposed to manufacturer brands.