27 resultados para Questionário SRS-22r

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the variation of photon field penumbra shape with initial electron beam diameter, for very narrow beams. A Varian Millenium MLC (Varian Medical Systems, Palo Alto, USA) and a Brainlab m3 microMLC (Brainlab AB. Feldkirchen, Germany) were used, with one Varian iX linear accelerator, to produce fields that were (nominally) 0.20 cm across. Dose profiles for these fields were measured using radiochromic film and compared with the results of simulations completed using BEAMnrc and DOSXYZnrc, where the initial electron beam was set to FWHM = 0.02, 0.10, 0.12, 0.15, 0.20 and 0.50 cm. Increasing the electron-beam FWHM produced increasing occlusion of the photon source by the closely spaced collimator leaves and resulted in blurring of the simulated profile widths from 0.26 to 0.64 cm, for the MLC, from 0.12 to 0.43 cm, for the microMLC. Comparison with measurement data suggested that the electron spot size in the clinical linear accelerator was between FWHM = 0.10 and 0.15 cm, encompassing the result of our previous output-factor based work, which identified a FWHM of 0.12. Investigation of narrow-beam penumbra variation has been found to be a useful procedure, with results varying noticeably with linear accelerator spot size and allowing FWHM estimates obtained using other methods to be verified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This study investigated the sensitivity of calculated stereotactic radiotherapy and radiosurgery doses to the accuracy of the beam data used by the treatment planning system. Methods Two sets of field output factors were acquired using fields smaller than approximately 1 cm2, for inclusion in beam data used by the iPlan treatment planning system (Brainlab, Feldkirchen, Germany). One set of output factors were measured using an Exradin A16 ion chamber (Standard Imaging, Middleton, USA). Although this chamber has a relatively small collecting volume (0.007 cm3), measurements made in small fields using this chamber are subject to the effects of volume averaging, electronic disequilibrium and chamber perturbations. The second, more accurate, set of measurements were obtained by applying perturbation correction factors, calculated using Monte Carlo simulations according to a method recommended by Cranmer-Sargison et al. [1] to measurements made using a 60017 unshielded electron diode (PTW, Freiburg, Germany). A series of 12 sample patient treatments were used to investigate the effects of beam data accuracy on resulting planned dose. These treatments, which involved 135 fields, were planned for delivery via static conformal arcs and 3DCRT techniques, to targets ranging from prostates (up to 8 cm across) to meningiomas (usually more than 2 cm across) to arterioveinous malformations, acoustic neuromas and brain metastases (often less than 2 cm across). Isocentre doses were calculated for all of these fields using iPlan, and the results of using the two different sets of beam data were evaluated. Results While the isocentre doses for many fields are identical (difference = 0.0 %), there is a general trend for the doses calculated using the data obtained from corrected diode measurements to exceed the doses calculated using the less-accurate Exradin ion chamber measurements (difference\0.0 %). There are several alarming outliers (circled in the Fig. 1) where doses differ by more than 3 %, in beams from sample treatments planned for volumes up to 2 cm across. Discussion and conclusions These results demonstrate that treatment planning dose calculations for SRT/SRS treatments can be substantially affected when beam data for fields smaller than approximately 1 cm2 are measured inaccurately, even when treatment volumes are up to 2 cm across.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The measurement of Cobb angles on radiographs of patients with spinal deformities is routine practice in spinal clinics. The technique relies on the use and availability of specialist equipment such as a goniometer, cobbometer or protractor. The aim of this study was to validate the use of i-Phone (Apple Inc) combined with Tilt Meter Pro software as compared to a protractor in the measurement of Cobb angles. The i-Phone combined with Tilt Meter Pro software offers a faster alternative to the traditional method of Cobb angle measurement. The use of i-Phone offers a more convenient way of measuring Cobb angles in the outpatient setting. The intra-observer repeatability of the iPhone is equivalent to the protractor in the measurement of Cobb angles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surgical treatment of scoliosis is quantitatively assessed in the clinic using radiographic measures of deformity correction, as well as the rib hump, but it is important to understand the extent to which these quantitative measures correlate with self-reported improvements in patients’ quality of life following surgery. The purpose of this prospective study was to evaluate the relationship between clinical outcomes of thoracoscopic anterior scoliosis surgery and deformity correction using the Scoliosis Research Society questionnaire (SRS-24). Patients undergoing thoracoscopic anterior scoliosis correction report good SRS scores which are comparable to those reported in previous studies for both open and thoracoscopic scoliosis correction procedures. Major Cobb correction is a significant predictor of patient satisfaction when comparing subgroups of patients with the highest and lowest major curve corrections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between deformity correction and self-reported patient satisfaction after thoracoscopic anterior scoliosis surgery is unknown. Scoliosis Research Society questionnaire scores, radiographic outcomes, and rib hump correction were prospectively assessed for a group of 100 patients pre-operatively and at two years after surgery. Patients with lower post-op major Cobb angles report significantly higher SRS scores than patients with higher post-op Cobb angles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prospective clinical case series of 100 patients receiving thoracoscopic anterior scoliosis correction surgery. The objective was to evaluate the relationship between clinical outcomes of thoracoscopic anterior scoliosis surgery and deformity correction using the Scoliosis Research Society (SRS) outcomes instrument questionnaire. The surgical treatment of scoliosis is quantitatively assessed in the clinic using radiographic measures of deformity correction, as well as the rib hump, but it is important to understand the extent to which these quantitative measures correlate with self-reported improvements in patients’ quality of life following surgery. A series of 100 consecutive adolescent idiopathic scoliosis patients received a single anterior rod via a thoracoscopic approach at the Mater Children’s Hospital, Brisbane, Australia. Patients completed SRS outcomes questionnaires pre-operatively and at 24 months post-operatively. There were 94 females and 6 males with a mean age of 16.1 years. The mean Cobb angle improved from 52º pre-operatively to 25º post-operatively (52%) and the mean rib hump improved from 16º to 8º (51%). The mean total SRS score for the cohort was 99.4/120. None of the deformity related parameters in the multiple regression were significant. However, patients with the lowest post-operative major Cobb angles reported significantly higher SRS scores than those with the highest post-operative Cobb angles, but there was no difference on the basis of rib hump correction. There were no significant differences between patients with either rod fractures or screw-related complications compared to those without complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. Surgical treatment of scoliosis is assessed in the spine clinic by the surgeon making numerous measurements on X-Rays as well as the rib hump. But it is important to understand which of these measures correlate with self-reported improvements in patients’ quality of life following surgery. The objective of this study was to examine the relationship between patient satisfaction after thoracoscopic (keyhole) anterior scoliosis surgery and standard deformity correction measures using the Scoliosis Research Society (SRS) adolescent questionnaire. Methods. A series of 100 consecutive adolescent idiopathic scoliosis patients received a single anterior rod via a keyhole approach at the Mater Children’s Hospital, Brisbane. Patients completed SRS outcomes questionnaires before surgery and again at 24 months after surgery. Multiple regression and t-tests were used to investigate the relationship between SRS scores and deformity correction achieved after surgery. Results. There were 94 females and 6 males with a mean age of 16.1 years. The mean Cobb angle improved from 52º pre-operatively to 21º for the instrumented levels post-operatively (59% correction) and the mean rib hump improved from 16º to 8º (51% correction). The mean total SRS score for the cohort was 99.4/120 which indicated a high level of satisfaction with the results of their scoliosis surgery. None of the deformity related parameters in the multiple regressions were significant. However, the twenty patients with the smallest Cobb angles after surgery reported significantly higher SRS scores than the twenty patients with the largest Cobb angles after surgery, but there was no difference on the basis of rib hump correction. Discussion. Patients undergoing thoracoscopic (keyhole) anterior scoliosis correction report good SRS scores which are comparable to those in previous studies. We suggest that the absence of any statistically significant difference in SRS scores between patients with and without rod or screw complications is because these complications are not associated with any clinically significant loss of correction in our patient group. The Cobb angle after surgery was the only significant predictor of patient satisfaction when comparing subgroups of patients with the largest and smallest Cobb angles after surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigated the grain size dependence of mechanical properties and deformation mechanisms of microcrystalline (mc) and nanocrystalline (nc: grain size below 100 nm) Mg-5wt% Al alloys. The Hall-Petch relationship was investigated by both instrumented indentation tests and compression tests. The test results from the indentation tests and compression tests match well with each other. The breakdown of Hall-Petch relationship and the elevated strain rate sensitivity (SRS) of present Mg-5wt% Al alloys when the grain size was reduced below 58nm indicated the more significant role of GB mediated mechanisms in plastic deformation process. However, the relatively smaller SRS values compared to GB sliding and coble creep process suggested the plastic deformation in the current study is still dislocation mediated mechanism dominant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The relationship between radiologic union and clinical outcomes in thoracoscopic scoliosis surgery is not clear, as apparent non-union of a spinal fusion does not always correspond to a poor clinical result. The aim of this study was to evaluate for the first time the interbody fusion rates using low dose CT scans at minimum 24 months after thoracoscopic scoliosis surgery, and to explore the relationship between fusion scores and; (i) rod diameter, (ii) graft type, (iii) fusion level, (iv) implant failure, and (v) lateral position in the disc space. The study found that moderate fusion scores on the Sucato scale secure successful clinical outcomes in thoracoscopic scoliosis surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Australia, there is only one, newly established, dedicated mental health service catering specifically for the signing *Deaf community. It is staffed by four part-time hearing professionals and based in Brisbane. There are currently no Deaf psychologists or psychiatrists and there is no valid or reliable empirical evidence on outcomes for Deaf people accessing specialised or mainstream mental health services. Further compounding these issues, is the fact that there are no sign language versions of the most common standardised mental health or psychological instruments available to clinicians in Australia. Contemporary counselling literature is acknowledging the role of the therapeutic alliance and the impact of 'common factors' on therapeutic outcomes. However, these issues are complicated by the relationship between the Deaf client and the hearing therapist being a cross-cultural exchange. The disability model of deafness is contentious and few professionals in Australia have the requisite knowledge and understanding of deafness from a cultural perspective to attend to the therapeutic relationship with this in mind. Consequently, Deaf people are severely disadvantaged by the current lack of services, resources and skilled professionals in the field of deafness and psychology in this country. The primary aim of the following program of research has been to propose a model for culturally affirmative service delivery and to provide clinicians with tools to evaluate the effect of their therapeutic work with Deaf people seeking mental health treatment. The research document is presented as a thesis by publication and comprises four specific objectives formulated in response to the lack of existing services and resources. The first objective was to explore the use of social constructionist counselling techniques and a reflecting team with Deaf clients, hearing therapists and an interpreter. Following the establishment of a pilot counselling clinic, indepth semi-structured interviews were conducted with two long-term clients following the one year pilot of this service. These interviews generated recommendations for the development of a new 'enriched' model of counselling to be implemented and evaluated in later stages of the research program. The second objective was to identify appropriate psychometric measures that could be translated into Australian Sign Language (Auslan) for research into efficacy, effectiveness and counselling outcomes. Two instruments were identified as potentially suitable; the Outcome Rating Scale (ORS), a measure of global functioning, and the Session Rating Scale (SRS), a measure of therapeutic alliance. A specialised team of bi-lingual and bi-cultural interpreters, native signers and the primary researcher for this thesis, produced the ORS-Auslan and the SRS-Auslan in DVD format, using the translation and back-translation process. The third objective was to establish the validity and reliability of these new Auslan measures based on normative data from the Deaf community. Data from the ORS-Auslan was collected from one clinical and one non-clinical sample of Deaf people. Statistical analyses revealed that the ORS-Auslan is reliable, valid and adequately distinguishes between clinical and non-clinical presentations. Furthermore, construct validity has been established using a yet to be validated sign language version of the Depression, Anxiety and Stress Scale-21 items (DASS-21), providing a platform for further research using the DASS-21 with Deaf people. The fourth objective was to evaluate counselling outcomes following the implementation of an enriched counselling service, based on the findings generated by the first objective, and using the newly translated Auslan measures. A second university counselling clinic was established and implemented over the course of one year. Practice-based evidence guided the research and the ORS-Auslan and the SRS-Auslan were administered at every session and provided outcome data on Deaf clients' global functioning. Data from six clients over the course of ten months indicated that this culturally affirmative model was an effective approach for these six clients. This is the first time that outcome data have been collected in Australia using valid and reliable Auslan measures to establish preliminary evidence for the effectiveness of any therapeutic intervention for clinical work with adult, signing Deaf clients. The research generated by this thesis contributes theoretical knowledge, professional development and practical resources that can be used by a variety of mental health clinicians in the context of mental health service delivery to Deaf clients in Australia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work presented in this poster outlines the steps taken to model a 4 mm conical collimator (BrainLab, Germany) on a Novalis Tx linear accelerator (Varian, Palo Alto, USA) capable of producing a 6MV photon beam for treatment of Stereotactic Radiosurgery (SRS) patients. The verification of this model was performed by measurements in liquid water and in virtual water. The measurements involved scanning depth dose and profiles in a water tank plus measurement of output factors in virtual water using Gafchromic® EBT3 film.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To provide an overview and a critical appraisal of systematic reviews (SRs) of published interventions for the prevention/management of radiation dermatitis. Methods and Materials: We searched Medline, CINAHL, Embase, and the Cochrane Library. We also manually searched through individual reference lists of potentially eligible articles and a number of key journals in the topic area. Two authors screened all potential articles and included eligible SRs. Two authors critically appraised and extracted key findings from the included reviews using AMSTAR (the measurement tool for “assessment of multiple systematic reviews”). Results: Of 1837 potential titles, 6 SRs were included. A number of interventions have been reported to be potentially beneficial for managing radiation dermatitis. Interventions evaluated in these reviews included skin care advice, steroidal/nonsteroidal topical agents, systemic therapies, modes of radiation delivery, and dressings. However, all the included SRs reported that there is insufficient evidence supporting any single effective intervention. The methodological quality of the included studies varied, and methodological shortfalls in these reviews might create biases to the overall results or recommendations for clinical practice. Conclusions: An up-to-date high-quality SR in the prevention/management of radiation dermatitis is needed to guide practice and direction for future research. We recommend that clinicians or guideline developers critically evaluate the information of SRs in their decision making.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Systematic reviews (SRs) are increasingly recognised as the standard approach in summarising health research and influence clinical nursing practice and health care decisions (Coster and Norman, 2009, Grimshaw and Russell, 1993 and Griffiths and Norman, 2005). High quality SRs should have a clearly stated set of objectives with pre-defined eligibility criteria for studies; an explicit reproducible methodology; a systematic search that attempts to identify all studies that would meet the eligibility criteria; an assessment of the validity of the findings of the included studies; the assessment of risk of bias; and a systematic presentation and synthesis of the characteristics of findings of the included study (Higgins and Green, 2011). Although SRs are highly regarded and are expected to be rigorous, just as other research, their quality may vary (Choi et al., 2001 and Hoving et al., 2001)...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effect of very small air gaps (less than 1 mm) on the dosimetry of small photon fields used for stereotactic treatments. Measurements were performed with optically stimulated luminescent dosimeters (OSLDs) for 6 MV photons on a Varian 21iX linear accelerator with a Brainlab μMLC attachment for square field sizes down to 6 mm × 6 mm. Monte Carlo simulations were performed using EGSnrc C++ user code cavity. It was found that the Monte Carlo model used in this study accurately simulated the OSLD measurements on the linear accelerator. For the 6 mm field size, the 0.5 mm air gap upstream to the active area of the OSLD caused a 5.3 % dose reduction relative to a Monte Carlo simulation with no air gap. A hypothetical 0.2 mm air gap caused a dose reduction > 2 %, emphasizing the fact that even the tiniest air gaps can cause a large reduction in measured dose. The negligible effect on an 18 mm field size illustrated that the electronic disequilibrium caused by such small air gaps only affects the dosimetry of the very small fields. When performing small field dosimetry, care must be taken to avoid any air gaps, as can be often present when inserting detectors into solid phantoms. It is recommended that very small field dosimetry is performed in liquid water. When using small photon fields, sub-millimetre air gaps can also affect patient dosimetry if they cannot be spatially resolved on a CT scan. However the effect on the patient is debatable as the dose reduction caused by a 1 mm air gap, starting out at 19% in the first 0.1 mm behind the air gap, decreases to < 5 % after just 2 mm, and electronic equilibrium is fully re-established after just 5 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is imperative that we consider the use of current and emerging technologies in terms of the nature of our learners, the physical environment of the lecture theatre, and how technology may help to support appropriate pedagogies that facilitate the capturing of student attention in active engaging learning experiences. It is argued that a re-evaluation of pedagogy is required to address the tech-savy traits of the 21st century learner and the extent to which their mobile devices are capable of not only distracting them from learning but also enhancing face-to-face learning experiences.