40 resultados para HYPERCHOLESTEROLEMIC SUBJECTS

em Queensland University of Technology - ePrints Archive


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on students’ perceptions, experiences and beliefs about the voluntary use of Facebook in Advertising, Law, Nursing and Creative Industries’ subjects at an Australian University. The researchers conducted in-depth interviews with students and the transcriptions were analysed using the constant comparison method. This resulted in a number of emergent themes, of which six are explored in this paper. The findings suggest that students are quite divergent in their responses to academics using Facebook in their subjects. They do not always see its relevance to the subject and are somewhat ambivalent about how it facilitates peer-to-peer relationships or a better relationship with the lecturer. The study also identifies themes relating to cynicism and intrusion into social spaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recombinant glucagon-like peptide-1 (7–36)amide (rGLP-1) was recently shown to cause significant weight loss in type 2 diabetics when administered for 6 weeks as a continuous subcutaneous infusion. The mechanisms responsible for the weight loss are not clarified. In the present study, rGLP-1 was given for 5d by prandial subcutaneous injections (PSI) (76nmol 30min before meals, four times daily; a total of 302·4nmol/24h) or by continuous subcutaneous infusion (CSI) (12·7nmol/h; a total of 304·8nmol/24h). This was performed in nineteen healthy obese subjects (mean age 44·2 (sem 2·5) years; BMI 39·0 (sem 1·2)kg/m2) in a prospective randomised, double-blind, placebo-controlled, cross-over study. Compared with the placebo, rGLP-1 administered as PSI and by CSI generated a 15% reduction in mean food intake per meal (P=0·02) after 5d treatment. A weight loss of 0·55 (sem 0·2) kg (P<0·05) was registered after 5d with PSI of rGLP-1. Gastric emptying rate was reduced during both PSI (P<0·001) and CSI (P<0·05) treatment, but more rapidly and to a greater extent with PSI of rGLP-1. To conclude, a 5d treatment of rGLP-1 at high doses by PSI, but not CSI, promptly slowed gastric emptying as a probable mechanism of action of increased satiety, decreased hunger and, hence, reduced food intake with an ensuing weight loss.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study assessed the reliability and validity of a palm-top-based electronic appetite rating system (EARS) in relation to the traditional paper and pen method. Twenty healthy subjects [10 male (M) and 10 female (F)] — mean age M=31 years (S.D.=8), F=27 years (S.D.=5); mean BMI M=24 (S.D.=2), F=21 (S.D.=5) — participated in a 4-day protocol. Measurements were made on days 1 and 4. Subjects were given paper and an EARS to log hourly subjective motivation to eat during waking hours. Food intake and meal times were fixed. Subjects were given a maintenance diet (comprising 40% fat, 47% carbohydrate and 13% protein by energy) calculated at 1.6×Resting Metabolic Rate (RMR), as three isoenergetic meals. Bland and Altman's test for bias between two measurement techniques found significant differences between EARS and paper and pen for two of eight responses (hunger and fullness). Regression analysis confirmed that there were no day, sex or order effects between ratings obtained using either technique. For 15 subjects, there was no significant difference between results, with a linear relationship between the two methods that explained most of the variance (r2 ranged from 62.6 to 98.6). The slope for all subjects was less than 1, which was partly explained by a tendency for bias at the extreme end of results on the EARS technique. These data suggest that the EARS is a useful and reliable technique for real-time data collection in appetite research but that it should not be used interchangeably with paper and pen techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present paper reviews the reliability and validity of visual analogue scales (VAS) in terms of (1) their ability to predict feeding behaviour, (2) their sensitivity to experimental manipulations, and (3) their reproducibility. VAS correlate with, but do not reliably predict, energy intake to the extent that they could be used as a proxy of energy intake. They do predict meal initiation in subjects eating their normal diets in their normal environment. Under laboratory conditions, subjectively rated motivation to eat using VAS is sensitive to experimental manipulations and has been found to be reproducible in relation to those experimental regimens. Other work has found them not to be reproducible in relation to repeated protocols. On balance, it would appear, in as much as it is possible to quantify, that VAS exhibit a good degree of within-subject reliability and validity in that they predict with reasonable certainty, meal initiation and amount eaten, and are sensitive to experimental manipulations. This reliability and validity appears more pronounced under the controlled (but more arti®cial) conditions of the laboratory where the signal : noise ratio in experiments appears to be elevated relative to real life. It appears that VAS are best used in within-subject, repeated-measures designs where the effect of different treatments can be compared under similar circumstances. They are best used in conjunction with other measures (e.g. feeding behaviour, changes in plasma metabolites) rather than as proxies for these variables. New hand-held electronic appetite rating systems (EARS) have been developed to increase reliability of data capture and decrease investigator workload. Recent studies have compared these with traditional pen and paper (P&P) VAS. The EARS have been found to be sensitive to experimental manipulations and reproducible relative to P&P. However, subjects appear to exhibit a signi®cantly more constrained use of the scale when using the EARS relative to the P&P. For this reason it is recommended that the two techniques are not used interchangeably

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article provides an overview of the concept of vulnerability through the lens of the U.S. federal regulations for the protection of human subjects of research. General issues that emerge for nurse researchers working with regulated vulnerable populations are identified. Points of current controversy in the application of the regulations and current discourse about vulnerable groups are highlighted. Suggestions for negotiating the tension between federally regulated human subject requirements and the realities of research with vulnerable subjects are given. The limitations of the designation of vulnerable as a protection for human subjects will also be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to investigate the influence of water loading upon intraocular pressure (IOP), ocular pulse amplitude (OPA) and axial length. Twenty one young adult subjects who were classified based on their spherical equivalent refraction as either myopes (n=11), or emmetropes (n=10) participated. Measures of IOP, OPA and ocular biometrics were collected before, and then 10, 15, 25 and 30 minutes following the ingestion of 1000 ml of water. Significant increases in both IOP and OPA were found to occur following water loading (p<0.0001), with peaks in both parameters occurring at 10 minutes after water loading (mean ± SEM increase of 2.24 ± 0.31 mmHg in IOP and 0.46 ± 0.06 mmHg in OPA). Axial length was found to reduce significantly following water loading (p=0.0005), with the largest reduction in axial length evident 10 minutes after water drinking (mean decrease 12 ± 3 µm). A significant time by refractive error group interaction (p=0.048) was found in axial length, indicative of a different pattern of change in eye length following water loading between the myopic and emmetropic populations. The largest difference in axial length change was evident at 10 minutes after water loading with a 17 ± 5 µm reduction in axial length evident in the myopes and only a 6 ± 2 µm reduction in the emmetropes. These findings illustrate significant changes in ocular parameters in young adult subjects following water loading.