278 resultados para Nanometric displacement measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enterprise architecture (EA) management has become an intensively discussed approach to manage enterprise transformations. Despite the popularity and potential of EA, both researchers and practitioners lament a lack of knowledge about the realization of benefits from EA. To determine the benefits from EA, we explore the various dimensions of EA benefit realization and report on the development of a validated and robust measurement instrument. In this paper, we test the reliability and construct validity of the EA benefit realization model (EABRM), which we have designed based on the DeLone & McLean IS success model and findings from exploratory interviews. A confirmatory factor analysis confirms the existence of an impact of five distinct and individually important dimensions on the benefits derived from EA: EA artefact quality, EA infrastructure quality, EA service quality, EA culture, and EA use. The analysis presented in this paper shows that the EA benefit realization model is an instrument that demonstrates strong reliability and validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Qualitative and quantitative measurements of biomass components dissolved in the phosphonium ionic liquids (ILs), trihexyltetradecylphosphonium chloride ([P66614]Cl) and tributylmethylphosphonium methylsulphate ([P4441]MeSO 4), are obtained using attenuated total reflectance-FTIR. Absorption bands related to cellulose, hemicelluloses, and lignin dissolution monitored in situ in biomass-IL mixtures indicate lignin dissolution in both ILs and some holocellulose dissolution in the hydrophilic [P4441]MeSO 4. The kinetics of lignin dissolution reported here indicate that while dissolution in the hydrophobic IL [P66614]Cl appears to follow an accepted mechanism of acid catalyzed -aryl ether cleavage, dissolution in the hydrophilic IL [P4441]MeSO 4 does not appear to follow this mechanism and may not be followed by condensation reactions (initiated by reactive ketones). The measurement of lignin dissolution in phosphonium ILs based on absorbance at 1510 cm 1 has demonstrated utility. When coupled with the gravimetric Klason lignin method, ATR-FTIR study of reaction mixtures can lead to a better understanding of the delignification process. © 2012 Copyright Taylor and Francis Group, LLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The accurate evaluation of physical activity levels amongst youth is critical for quantifying physical activity behaviors and evaluating the effect of physical activity interventions. The purpose of this review is to evaluate contemporary approaches to physical activity evaluation amongst youth. Data sources: The literature from a range of sources was reviewed and synthesized to provide an overview of contemporary approaches for measuring youth physical activity. Results: Five broad categories are described: self-report, instrumental movement detection, biological approaches, direct observation, and combined methods. Emerging technologies and priorities for future research are also identified. Conclusions: There will always be a trade-off between accuracy and available resources when choosing the best approach for measuring physical activity amongst youth. Unfortunately, cost and logistical challenges may prohibit the use of "gold standard" physical activity measurement approaches such as doubly labelled water. Other objective methods such as heart rate monitoring, accelerometry, pedometry, indirect calorimetry, or a combination of measures have the potential to better capture the duration and intensity of physical activity, while self-reported measures are useful for capturing the type and context of activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differences in the NMR detectability of 39K in various excised rat tissues (liver, brain, kidney, muscle, and testes) have been observed. The lowest NMR detectability occurs for liver (61 ± 3% of potassium as measured by flame photometry) and highest for erythrocytes (100 ± 7%). These differences in detectability correlate with differences in the measured 39K NMR relaxation constants in the same tissues. 39K detectabilities were also found to correlate inversely with the mitochondrial content of the tissues. Mitochondria prepared from liver showed greatly reduced 39K NMR detectability when compared with the tissue from which it was derived, 31.6 ± 9% of potassium measured by flame photometry compared to 61 ± 3%. The detectability of potassium in mitochondria was too low to enable the measurement of relaxation constants. This study indicates that differences in tissue structure, particularly mitochondrial content are important in determining 39K detectability and measured relaxation rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data quality has become a major concern for organisations. The rapid growth in the size and technology of a databases and data warehouses has brought significant advantages in accessing, storing, and retrieving information. At the same time, great challenges arise with rapid data throughput and heterogeneous accesses in terms of maintaining high data quality. Yet, despite the importance of data quality, literature has usually condensed data quality into detecting and correcting poor data such as outliers, incomplete or inaccurate values. As a result, organisations are unable to efficiently and effectively assess data quality. Having an accurate and proper data quality assessment method will enable users to benchmark their systems and monitor their improvement. This paper introduces a granules mining for measuring the random degree of error data which will enable decision makers to conduct accurate quality assessment and allocate the most severe data, thereby providing an accurate estimation of human and financial resources for conducting quality improvement tasks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. Methods Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. Results Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort. Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion. When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. Conclusions The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Business process management (BPM) is becoming the dominant management paradigm. Business process modelling is central to BPM, and the resultant business process model the core artefact guiding subsequent process change. Thus, model quality is at the centre, mediating between the modelling effort and related growing investment in ultimate process improvements. Nonetheless, though research interest in the properties that differentiate high quality process models is longstanding, there have been no past reports of a valid, operationalised, holistic measure of business process model quality. In attention to this gap, this paper reports validation of a Business Process Model Quality measurement model, conceptualised as a single-order, formative index. Such a measurement model has value as the dependent variable in rigorously researching the drivers of model quality; as antecedent of ultimate process improvements; and potentially as an economical comparator and diagnostic for practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Factors associated with the development of hallux valgus (HV) are multifactorial and remain unclear. The objective of this systematic review and meta-analysis was to investigate characteristics of foot structure and footwear associated with HV. Design Electronic databases (Medline, Embase, and CINAHL) were searched to December 2010. Cross-sectional studies with a valid definition of HV and a non-HV comparison group were included. Two independent investigators quality rated all included papers. Effect sizes and 95% confidence intervals (CIs) were calculated (standardized mean differences (SMDs) for continuous data and risk ratios (RRs) for dichotomous data). Where studies were homogeneous, pooling of SMDs was conducted using random effects models. Results A total of 37 papers (34 unique studies) were quality rated. After exclusion of studies without reported measurement reliability for associated factors, data were extracted and analysed from 16 studies reporting results for 45 different factors. Significant factors included: greater first intermetatarsal angle (pooled SMD = 1.5, CI: 0.88–2.1), longer first metatarsal (pooled SMD = 1.0, CI: 0.48–1.6), round first metatarsal head (RR: 3.1–5.4), and lateral sesamoid displacement (RR: 5.1–5.5). Results for clinical factors (e.g., first ray mobility, pes planus, footwear) were less conclusive regarding their association with HV. Conclusions Although conclusions regarding causality cannot be made from cross-sectional studies, this systematic review highlights important factors to monitor in HV assessment and management. Further studies with rigorous methodology are warranted to investigate clinical factors associated with HV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Vertebral rotation found in structural scoliosis contributes to trunkal asymmetry which is commonly measured with a simple Scoliometer device on a patient's thorax in the forward flexed position. The new generation of mobile 'smartphones' have an integrated accelerometer, making accurate angle measurement possible, which provides a potentially useful clinical tool for assessing rib hump deformity. This study aimed to compare rib hump angle measurements performed using a Smartphone and traditional Scoliometer on a set of plaster torsos representing the range of torsional deformities seen in clinical practice. Methods. Nine observers measured the rib hump found on eight plaster torsos moulded from scoliosis patients with both a Scoliometer and an Apple iPhone on separate occasions. Each observer repeated the measurements at least a week after the original measurements, and were blinded to previous results. Intra-observer reliability and inter-observer reliability were analysed using the method of Bland and Altman and 95% confidence intervals were calculated. The Intra-Class Correlation Coefficients (ICC) were calculated for repeated measurements of each of the eight plaster torso moulds by the nine observers. Results. Mean absolute difference between pairs of iPhone/Scoliometer measurements was 2.1 degrees, with a small (1 degrees) bias toward higher rib hump angles with the iPhone. 95% confidence intervals for intra-observer variability were +/- 1.8 degrees (Scoliometer) and +/- 3.2 degrees (iPhone). 95% confidence intervals for inter-observer variability were +/- 4.9 degrees (iPhone) and +/- 3.8 degrees (Scoliometer). The measurement errors and confidence intervals found were similar to or better than the range of previously published thoracic rib hump measurement studies. Conclusions. The iPhone is a clinically equivalent rib hump measurement tool to the Scoliometer in spinal deformity patients. The novel use of plaster torsos as rib hump models avoids the variables of patient fatigue and discomfort, inconsistent positioning and deformity progression using human subjects in a single or multiple measurement sessions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study considered factors influencing teachers' reporting of child sexual abuse (CSA). Conducted in three Australian jurisdictions with different reporting laws and policies, the study focused on teachers' actual past and anticipated future reporting of CSA. A sample of 470 teachers within randomly selected rural and urban schools was surveyed, to identify training and experience; knowledge of reporting legislation and policy; attitudes; and reporting practices. Factors influencing actual past reporting and anticipated future reporting were identified using logistic regression modelling. This is the first study to simultaneously examine the effect of important influences in reporting practice using both retrospective and prospective approaches across jurisdictions with different reporting laws. Teachers who have actually reported CSA in the past are more likely have higher levels of policy knowledge, and hold more positive attitudes towards reporting CSA along three specific dimensions: commitment to the reporting role; confidence in the system's effective response to their reporting; and they are more likely to be able to override their concerns about the consequences of their reporting. Teachers indicating intention to report hypothetical scenarios are more likely to hold reasonable grounds for suspecting CSA, to recognise that significant harm has been caused to the child, to know that their school policy requires a report, and to be able to override their concerns about the consequences of their reporting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total hip arthroplasty (THA) has a proven clinical record for providing pain relief and return of function to patients with disabling arthritis. There are many successful options for femoral implant design and fixation. Cemented, polished, tapered femoral implants have been shown to have excellent results in national joint registries and long-term clinical series. These implants are usually 150mm long at their lateral aspect. Due to their length, these implants cannot always be offered to patients due to variations in femoral anatomy. Polished, tapered implants as short as 95mm exist, however their small proximal geometry (neck offset and body size) limit their use to smaller stature patients. There is a group of patients in which a shorter implant with a maintained proximal body size would be advantageous. There are also potential benefits to a shorter implant in standard patient populations such as reduced bone removal due to reduced reaming, favourable loading of the proximal femur, and the ability to revise into good proximal bone stock if required. These factors potentially make a shorter implant an option for all patient populations. The role of implant length in determining the stability of a cemented, polished, tapered femoral implant is not well defined by the literature. Before changes in implant design can be made, a better understanding of the role of each region in determining performance is required. The aim of the thesis was to describe how implant length affects the stability of a cemented, polished, tapered femoral implant. This has been determined through an extensive body of laboratory testing. The major findings are that for a given proximal body size, a reduction in implant length has no effect on the torsional stability of a polished, tapered design, while a small reduction in axial stability should be expected. These findings are important because the literature suggests that torsional stability is the major determinant of long-term clinical performance of a THA system. Furthermore, a polished, tapered design is known to be forgiving of cement-implant interface micromotion due to the favourable wear characteristics. Together these findings suggest that a shorter polished, tapered implant may be well tolerated. The effect of a change in implant length on the geometric characteristics of polished, tapered design were also determined and applied to the mechanical testing. Importantly, interface area does play a role in stability of the system; however it is the distribution of the interface and not the magnitude of the area that defines stability. Taper angle (at least in the range of angles seen in this work) was shown not to be a determinant of axial or torsional stability. A range of implants were tested, comparing variations in length, neck offset and indication (primary versus cement-in-cement revision). At their manufactured length, the 125mm implants were similar to their longer 150mm counterparts suggesting that they may be similarly well tolerated in the clinical environment. However, the slimmer cement-in-cement revision implant was shown to have a poorer mechanical performance, suggesting their use in higher demand patients may be hazardous. An implant length of 125mm has been shown to be quite stable and the results suggest that a further reduction to 100mm may be tolerated. However, further work is required. A shorter implant with maintained proximal body size would be useful for the group of patients who are unable to access the current standard length implants due to variations in femoral anatomy. Extending the findings further, the similar function with potential benefits of a shorter implant make their application to all patients appealing.