128 resultados para cone index


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the effect of rod–cone interactions on mesopic visual reaction time (RT). Rod and cone photoreceptor excitations were independently controlled using a four-primary photostimulator. It was observed that (1) lateral rod–cone interactions increase the cone-mediated RTs; (2) the rod–cone interactions are strongest when rod sensitivity is maximal in a dark surround, but weaker with increased rod activity in a light surround; and (3) the presence of a dark surround nonselectively increased the mean and variability of chromatic (+L-M, S-cone) and luminance (L+M+S) RTs independent of the level of rod activity. The results demonstrate that lateral rod–cone interactions must be considered when deriving mesopic luminous efficiency using RT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the relative contributions of rods, cones and melanopsin to pupil responses in humans using temporal sinusoidal stimulation for light levels spanning the low mesopic to photopic range. Methods: A four-primary Ganzfeld photostimulator controlled flicker stimulations at seven light levels (-2.7 to 2 log cd/m2) and five frequencies (0.5 to 8Hz). Pupil diameter was measured using a high-resolution eyetracker. Three kinds of sinusoidal photoreceptor modulations were generated using silent substitution: 1) rod modulation, 2) cone modulation, and 3) combined rod and cone modulation in phase (Experiment 1) or phase shifted (Experiment 2) from a fixed rod phase. The melanopsin excitation was computed for each condition. A vector sum model was used to estimate the relative contribution of rods, cones and melanopsin to the pupil response. Results: From Experiment 1, the pupil frequency response peaked at 1Hz at two mesopic light levels for the three modulation conditions. Analyzing the rod-cone phase difference for the combined modulations (Experiment 2) identified a V-shaped response amplitude with a minimum between 135° and 180°. The pupil response phases increased as cone modulation phase increased. The pupil amplitude increased with increasing light level for cone and combined in-phase rod and cone modulation, but not for the rod modulation. Conclusions: These results demonstrate that cone- and rod-pathway contributions are more predominant than melanopsin contribution to the phasic pupil response. The combined rod, cone and melanopsin inputs to the phasic state of the pupil light reflex follow linear summation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose There is a suggestion that the long wavelength-sensitive (LWS)-to-middle wavelength-sensitive (MWS) cone ratio in the retina is associated with myopia. The aim was to measure the LWS/MWS amplitude modulation ratio, an estimate of the LWS/MWS cone ratio, in young adult emmetropes and myopes. Methods Multifocal visual evoked potentials were measured when the LWS and MWS cone systems were excited separately using the method of silent substitution. The 30 young adult participants (22 to 33 years) included 10 emmetropes (mean [±SD] refraction, +0.3 [±0.4] diopters [D]) and 20 myopes (mean [±SD] refraction, -3.4 [±1.7] D). Results The LWS/MWS amplitude modulation ratios ranged from 0.56 to 1.80 in the central 3- to 13-degree diameter ring and from 0.94 to 1.91 in the peripheral 13- to 30-degree diameter ring. Within the central ring, the mean (±SD) ratios were 1.20 (±0.26) and 1.20 (±0.33) for the emmetropic and the myopic groups, respectively. For the peripheral ring, the mean (±SD) ratios were 1.48 (±0.27) and 1.30 (±0.27), respectively. There were no significant differences in the ratios between the emmetropic and myopic groups for either the central (p = 0.99) or peripheral (p = 0.08) rings. For the latter, more myopic refractive error was associated with lower LWS/MWS amplitude modulation ratio; the refraction explained 16% (p = 0.02) of variation in ratio. Conclusions The relationship between the LWS/MWS amplitude modulation ratios and refraction at 13 to 30 degrees indicates that a large longitudinal study of changes in refraction in persons with known cone ratio is required to determine if a low LWS/MWS cone ratio is associated with myopia development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purposes: The first objective was to propose a new model representing the balance level of adults with intellectual and developmental disabilities (IDD) using Principal Components Analysis (PCA); and the second objective was to use the results from the PCA recorded by regression method to construct and validate summative scales of the standardized values of the index, which may be useful to facilitate a balance assessment in adults with IDD. Methods: A total of 801 individuals with IDD (509 males) mean 33.1±8.5 years old, were recruited from Special Olympic Games in Spain 2009 to 2012. The participants performed the following tests: the timed-stand test, the single leg stance test with open and closed eyes, the Functional Reach Test, the Expanded Timed-Get-up-and-Go Test. Data was analyzed using principal components analysis (PCA) with Oblimin rotation and Kaiser normalization. We examined the construct validity of our proposed two-factor model underlying balance for adults with IDD. The scores from PCA were recorded by regression method and were standardized. Results: The Component Plot and Rotated Space indicated that a two-factor solution (Dynamic and Static Balance components) was optimal. The PCA with direct Oblimin rotation revealed a satisfactory percentage of total variance explained by the two factors: 51.6 and 21.4%, respectively. The median score standardized for component dynamic and static of the balance index for adults with IDD is shown how references values. Conclusions: Our study may lead to improvements in the understanding and assessment of balance in adults with IDD. First, it confirms that a two-factor model may underlie the balance construct, and second, it provides an index that may be useful for identifying the balance level for adults with IDD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The purpose of this study was the development of a valid and reliable “Mechanical and Inflammatory Low Back Pain Index” (MIL) for assessment of non-specific low back pain (NSLBP). This 7-item tool assists practitioners in determining whether symptoms are predominantly mechanical or inflammatory. Methods Participants (n = 170, 96 females, age = 38 ± 14 years-old) with NSLP were referred to two Spanish physiotherapy clinics and completed the MIL and the following measures: the Roland Morris Questionnaire (RMQ), SF-12 and “Backache Index” (BAI) physical assessment test. For test-retest reliability, 37 consecutive patients were assessed at baseline and three days later during a non-treatment period. Face and content validity, practical characteristics, factor analysis, internal consistency, discriminant validity and convergent validity were assessed from the full sample. Results A total of 27 potential items that had been identified for inclusion were subsequently reduced to 11 by an expert panel. Four items were then removed due to cross-loading under confirmatory factor analysis where a two-factor model yielded a good fit to the data (χ2 = 14.80, df = 13, p = 0.37, CFI = 0.98, and RMSEA = 0.029). The internal consistency was moderate (α = 0.68 for MLBP; 0.72 for ILBP), test-retest reliability high (ICC = 0.91; 95%CI = 0.88-0.93) and discriminant validity good for either MLBP (AUC = 0.74) and ILBP (AUC = 0.92). Convergent validity was demonstrated through similar but weak correlations between the ILBP and both the RMQ and BAI (r = 0.34, p < 0.001) and the MLBP and BAI (r = 0.38, p < 0.001). Conclusions The MIL is a valid and reliable clinical tool for patients with NSLBP that discriminates between mechanical and inflammatory LBP. Keywords: Low back pain; Psychometrics properties; Pain measurement; Screening tool; Inflammatory; Mechanical

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In images with low contrast-to-noise ratio (CNR), the information gain from the observed pixel values can be insufficient to distinguish foreground objects. A Bayesian approach to this problem is to incorporate prior information about the objects into a statistical model. A method for representing spatial prior information as an external field in a hidden Potts model is introduced. This prior distribution over the latent pixel labels is a mixture of Gaussian fields, centred on the positions of the objects at a previous point in time. It is particularly applicable in longitudinal imaging studies, where the manual segmentation of one image can be used as a prior for automatic segmentation of subsequent images. The method is demonstrated by application to cone-beam computed tomography (CT), an imaging modality that exhibits distortions in pixel values due to X-ray scatter. The external field prior results in a substantial improvement in segmentation accuracy, reducing the mean pixel misclassification rate for an electron density phantom from 87% to 6%. The method is also applied to radiotherapy patient data, demonstrating how to derive the external field prior in a clinical context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Symptom burden in chronic kidney disease (CKD) is poorly understood. To date, the majority of research focuses on single symptoms and there is a lack of suitable multidimensional symptom measures. The purpose of this study was to modify, translate, cross-culturally adapt and psychometrically analyse the Dialysis Symptom Index (DSI). Methods The study methods involved four phases: modification, translation, pilot-testing with a bilingual non-CKD sample and then psychometric testing with the target population. Content validity was assessed using an expert panel. Inter-rater agreement, test-retest reliability and Cronbach’s alpha coefficient were calculated to demonstrate reliability of the modified DSI. Discriminative and convergent validity were assessed to demonstrate construct validity. Results Content validity index during translation was 0.98. In the pilot study with 25 bilingual students a moderate to perfect agreement (Kappa statistic = 0.60-1.00) was found between English and Arabic versions of the modified DSI. The main study recruited 433 patients CKD with stages 4 and 5. The modified DSI was able to discriminate between non-dialysis and dialysis groups (p < 0.001) and demonstrated convergent validity with domains of the Kidney Disease Quality of Life short form. Excellent test-retest and internal consistency (Cronbach’s α = 0.91) reliability were also demonstrated. Conclusion The Arabic version of the modified DSI demonstrated good psychometric properties, measures the multidimensional nature of symptoms and can be used to assess symptom burden at different stages of CKD. The modified instrument, renamed the CKD Symptom Burden Index (CKD-SBI), should encourage greater clinical and research attention to symptom burden in CKD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heavy metal pollution of sediments is a growing concern in most parts of the world, and numerous studies focussed on identifying contaminated sediments by using a range of digestion methods and pollution indices to estimate sediment contamination have been described in the literature. The current work provides a critical review of the more commonly used sediment digestion methods and identifies that weak acid digestion is more likely to provide guidance on elements that are likely to be bioavailable than other traditional methods of digestion. This work also reviews common pollution indices and identifies the Nemerow Pollution Index as the most appropriate method for establishing overall sediment quality. Consequently, a modified Pollution Index that can lead to a more reliable understanding of whole sediment quality is proposed. This modified pollution index is then tested against a number of existing studies and demonstrated to give a reliable and rapid estimate of sediment contamination and quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Spine Functional Index (SFI) is a patient reported outcome measure with sound clinimetric properties and clinical viability for the determination of whole-spine impairment. To date, no validated Turkish version is available. The purpose of this study is to cross-culturally adapted the SFI for Turkish-speaking patients (SFI-Tk) and determine the psychometric properties of reliability, validity and factor structure in a Turkish population with spine musculoskeletal disorders. Methods The SFI English version was culturally adapted and translated into Turkish using a double forward and backward method according to established guidelines. Patients (n = 285, cervical = l29, lumbar = 151, cervical and lumbar region = 5, 73% female, age 45 ± 1) with spine musculoskeletal disorders completed the SFI-Tk at baseline and after a seven day period for test-retest reliability. For criterion validity the Turkish version of the Functional Rating Index (FRI) was used plus the Neck Disability Index (NDI) for cervical patients and the Oswestry Disability Index (ODI) for back patients. Additional psychometric properties were determined for internal consistency (Chronbach’s α), criterion validity and factor structure. Results There was a high degree of internal consistency (α = 0.85, item range 0.80-0.88) and test-retest reliability (r = 0.93, item range = 0.75-0.95). The factor analysis demonstrated a one-factor solution explaining 24.2% of total variance. Criterion validity with the ODI was high (r = 0.71, p < 0.001) while the FRI and NDI were fair (r = 0.52 and r = 0.58, respectively). The SFI-Tk showed no missing responses with the ‘half-mark’ option used in 11.75% of total responses by 77.9% of participants. Measurement error from SEM and MDC90 were respectively 2.96% and 7.12%. Conclusions The SFI-Tk demonstrated a one-factor solution and is a reliable and valid instrument. The SFI-Tk consists of simple and easily understood wording and may be used to assess spine region musculoskeletal disorders in Turkish speaking patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To evaluate the influence of cone location and corneal cylinder on RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Methods In this prospective study, 156 eyes from 134 patients were enrolled. Complete ophthalmologic examination including manifest refraction, Best spectacle visual acuity (BSCVA), slit-lamp biomicroscopy was performed and corneal topography analysis was done. According to the cone location on the topographic map, the patients were divided into central and paracentral cone groups. Trial RGP lenses were selected based on the flat Sim K readings and a ‘three-point touch’ fitting approach was used. Over contact lens refraction was performed, residual astigmatism (RA) was measured and best-corrected RGP visual acuities (RGPVA) were recorded. Results The mean age (±SD) was 22.1 ± 5.3 years. 76 eyes (48.6%) had central and 80 eyes (51.4%) had paracentral cone. Prior to RGP lenses fitting mean (±SD) subjective refraction spherical equivalent (SRSE), subjective refraction astigmatism (SRAST) and BSCVA (logMAR) were −5.04 ± 2.27 D, −3.51 ± 1.68 D and 0.34 ± 0.14, respectively. There were statistically significant differences between central and paracentral cone groups in mean values of SRSE, SRAST, flat meridian (Sim K1), steep meridian (Sim K2), mean K and corneal cylinder (p-values < 0.05). Comparison of BSCVA to RGPVA shows that vision has improved 0.3 logMAR by RGP lenses (p < 0.0001). Mean (±SD) RA was −0.72 ± 0.39 D. There were no statistically significant differences between RGPVAs and RAs of central and paracentral cone groups (p = 0.22) and (p = 0.42), respectively. Pearson's correlation analysis shows that there is a statistically significant relationship between corneal cylinder and BSCVA and RGPVA, However, the relationship between corneal cylinder and residual astigmatism was not significant. Conclusions Cone location has no effect on the RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Corneal cylinder and Sim K values influence RGP-corrected visual acuities but do not influence residual astigmatism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND CONTEXT: The Neck Disability Index frequently is used to measure outcomes of the neck. The statistical rigor of the Neck Disability Index has been assessed with conflicting outcomes. To date, Confirmatory Factor Analysis of the Neck Disability Index has not been reported for a suitably large population study. Because the Neck Disability Index is not a condition-specific measure of neck function, initial Confirmatory Factor Analysis should consider problematic neck patients as a homogenous group. PURPOSE: We sought to analyze the factor structure of the Neck Disability Index through Confirmatory Factor Analysis in a symptomatic, homogeneous, neck population, with respect to pooled populations and gender subgroups. STUDY DESIGN: This was a secondary analysis of pooled data. PATIENT SAMPLE: A total of 1,278 symptomatic neck patients (67.5% female, median age 41 years), 803 nonspecific and 475 with whiplash-associated disorder. OUTCOME MEASURES: The Neck Disability Index was used to measure outcomes. METHODS: We analyzed pooled baseline data from six independent studies of patients with neck problems who completed Neck Disability Index questionnaires at baseline. The Confirmatory Factor Analysis was considered in three scenarios: the full sample and separate sexes. Models were compared empirically for best fit. RESULTS: Two-factor models have good psychometric properties across both the pooled and sex subgroups. However, according to these analyses, the one-factor solution is preferable from both a statistical perspective and parsimony. The two-factor model was close to significant for the male subgroup (p<.07) where questions separated into constructs of mental function (pain, reading headaches and concentration) and physical function (personal care, lifting, work, driving, sleep, and recreation). CONCLUSIONS: The Neck Disability Index demonstrated a one-factor structure when analyzed by Confirmatory Factor Analysis in a pooled, homogenous sample of neck problem patients. However, a two-factor model did approach significance for male subjects where questions separated into constructs of mental and physical function. Further investigations in different conditions, subgroup and sex-specific populations are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The purpose of this study was to adapt and validate the Foot Function Index to the Spanish (FFI-Sp) following the guidelines of the American Academy of Orthopaedic Surgeons. Methods A cross-sectional study 80 participants with some foot pathology. A statistical analysis was made, including a correlation study with other questionnaires (the Foot Health Status Questionnaire, EuroQol 5-D, Visual Analogue Pain Scale, and the Short Form SF-12 Health Survey). Data analysis included reliability, construct and criterion-related validity and factor analyses. Results The principal components analysis with varimax rotation produced 3 principal factors that explained 80% of the variance. The confirmatory factor analysis showed an acceptable fit with a comparative fit index of 0.78. The FFI-Sp demonstrated excellent internal consistency on the three subscales: pain 0.95; disability 0.96; and activity limitation 0.69, the subscale that scored lowest. The correlation between the FFI-Sp and the other questionnaires was high to moderate. Conclusions The Spanish version of the Foot Function Index (FFI-Sp) is a tool that is a valid and reliable tool with a very good internal consistency for use in the assessment of pain, disability and limitation of the function of the foot, for use both in clinic and research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We commend Swanenburg et al. (2013) on translation, development, and clinimetric analysis of the NDI-G. However, the dual-factor structure with factor analysis and the high level of internal consistency (IC) highlighted in their discussion were not emphasized in the abstract or conclusion. These points may imply some inconsistencies with the final conclusions since determination of stable point estimates with the study's small sample are exceedingly difficult.