209 resultados para Synchronous generators
Resumo:
Nonlinear filter generators are common components used in the keystream generators for stream ciphers and more recently for authentication mechanisms. They consist of a Linear Feedback Shift Register (LFSR) and a nonlinear Boolean function to mask the linearity of the LFSR output. Properties of the output of a nonlinear filter are not well studied. Anderson noted that the m-tuple output of a nonlinear filter with consecutive taps to the filter function is unevenly distributed. Current designs use taps which are not consecutive. We examine m-tuple outputs from nonlinear filter generators constructed using various LFSRs and Boolean functions for both consecutive and uneven (full positive difference sets where possible) tap positions. The investigation reveals that in both cases, the m-tuple output is not uniform. However, consecutive tap positions result in a more biased distribution than uneven tap positions, with some m-tuples not occurring at all. These biased distributions indicate a potential flaw that could be exploited for cryptanalysis
Resumo:
The economiser is a critical component for efficient operation of coal-fired power stations. It consists of a large system of water-filled tubes which extract heat from the exhaust gases. When it fails, usually due to erosion causing a leak, the entire power station must be shut down to effect repairs. Not only are such repairs highly expensive, but the overall repair costs are significantly affected by fluctuations in electricity market prices, due to revenue lost during the outage. As a result, decisions about when to repair an economiser can alter the repair costs by millions of dollars. Therefore, economiser repair decisions are critical and must be optimised. However, making optimal repair decisions is difficult because economiser leaks are a type of interactive failure. If left unfixed, a leak in a tube can cause additional leaks in adjacent tubes which will need more time to repair. In addition, when choosing repair times, one also needs to consider a number of other uncertain inputs such as future electricity market prices and demands. Although many different decision models and methodologies have been developed, an effective decision-making method specifically for economiser repairs has yet to be defined. In this paper, we describe a Decision Tree based method to meet this need. An industrial case study is presented to demonstrate the application of our method.
Resumo:
Bronfenbrenner.s Bioecological Model, expressed as the developmental equation, D f PPCT, is the theoretical framework for two studies that bring together diverse strands of psychology to study the work-life interface of working adults. Occupational and organizational psychology is focused on the demands and resources of work and family, without emphasising the individual in detail. Health and personality psychology examine the individual but without emphasis on the individual.s work and family roles. The current research used Bronfenbrenner.s theoretical framework to combine individual differences, work and family to understand how these factors influence the working adult.s psychological functioning. Competent development has been defined as high well-being (measured as life satisfaction and psychological well-being) and high work engagement (as work vigour, work dedication and absorption in work) and as the absence of mental illness (as depression, anxiety and stress) and the absence of burnout (as emotional exhaustion, cynicism and professional efficacy). Study 1 and 2 were linked, with Study 1 as a cross-sectional survey and Study 2, a prospective panel study that followed on from the data used in Study1. Participants were recruited from a university and from a large public hospital to take part in a 3-wave, online study where they completed identical surveys at 3-4 month intervals (N = 470 at Time 1 and N = 198 at Time 3). In Study 1, hierarchical multiple regressions were used to assess the effects of individual differences (Block 1, e.g. dispositional optimism, coping self-efficacy, perceived control of time, humour), work and family variables (Block 2, e.g. affective commitment, skill discretion, work hours, children, marital status, family demands) and the work-life interface (Block 3, e.g. direction and quality of spillover between roles, work-life balance) on the outcomes. There were a mosaic of predictors of the outcomes with a group of seven that were the most frequent significant predictors and which represented the individual (dispositional optimism and coping self-efficacy), the workplace (skill discretion, affective commitment and job autonomy) and the work-life interface (negative work-to-family spillover and negative family-to-work spillover). Interestingly, gender and working hours were not important predictors. The effects of job social support, generally and for work-life issues, perceived control of time and egalitarian gender roles on the outcomes were mediated by negative work-to-family spillover, particularly for emotional exhaustion. Further, the effect of negative spillover on depression, anxiety and work engagement was moderated by the individual.s personal and workplace resources. Study 2 modelled the longitudinal relationships between the group of the seven most frequent predictors and the outcomes. Using a set of non-nested models, the relative influences of concurrent functioning, stability and change over time were assessed. The modelling began with models at Time 1, which formed the basis for confirmatory factor analysis (CFA) to establish the underlying relationships between the variables and calculate the composite variables for the longitudinal models. The CFAs were well fitting with few modifications to ensure good fit. However, using burnout and work engagement together required additional analyses to resolve poor fit, with one factor (representing a continuum from burnout to work engagement) being the only acceptable solution. Five different longitudinal models were investigated as the Well-Being, Mental Distress, Well-Being-Mental Health, Work Engagement and Integrated models using differing combinations of the outcomes. The best fitting model for each was a reciprocal model that was trimmed of trivial paths. The strongest paths were the synchronous correlations and the paths within variables over time. The reciprocal paths were more variable with weak to mild effects. There was evidence of gain and loss spirals between the variables over time, with a slight net gain in resources that may provide the mechanism for the accumulation of psychological advantage over a lifetime. The longitudinal models also showed that there are leverage points at which personal, psychological and managerial interventions can be targeted to bolster the individual and provide supportive workplace conditions that also minimise negative spillover. Bronfenbrenner.s developmental equation has been a useful framework for the current research, showing the importance of the person as central to the individual.s experience of the work-life interface. By taking control of their own life, the individual can craft a life path that is most suited to their own needs. Competent developmental outcomes were most likely where the person was optimistic and had high self-efficacy, worked in a job that they were attached to and which allowed them to use their talents and without too much negative spillover between their work and family domains. In this way, individuals had greater well-being, better mental health and greater work engagement at any one time and across time.
Resumo:
AC motors are largely used in a wide range of modern systems, from household appliances to automated industry applications such as: ventilations systems, fans, pumps, conveyors and machine tool drives. Inverters are widely used in industrial and commercial applications due to the growing need for speed control in ASD systems. Fast switching transients and the common mode voltage, in interaction with parasitic capacitive couplings, may cause many unwanted problems in the ASD applications. These include shaft voltage and leakage currents. One of the inherent characteristics of Pulse Width Modulation (PWM) techniques is the generation of the common mode voltage, which is defined as the voltage between the electrical neutral of the inverter output and the ground. Shaft voltage can cause bearing currents when it exceeds the amount of breakdown voltage level of the thin lubricant film between the inner and outer rings of the bearing. This phenomenon is the main reason for early bearing failures. A rapid development in power switches technology has lead to a drastic decrement of switching rise and fall times. Because there is considerable capacitance between the stator windings and the frame, there can be a significant capacitive current (ground current escaping to earth through stray capacitors inside a motor) if the common mode voltage has high frequency components. This current leads to noises and Electromagnetic Interferences (EMI) issues in motor drive systems. These problems have been dealt with using a variety of methods which have been reported in the literature. However, cost and maintenance issues have prevented these methods from being widely accepted. Extra cost or rating of the inverter switches is usually the price to pay for such approaches. Thus, the determination of cost-effective techniques for shaft and common mode voltage reduction in ASD systems, with the focus on the first step of the design process, is the targeted scope of this thesis. An introduction to this research – including a description of the research problem, the literature review and an account of the research progress linking the research papers – is presented in Chapter 1. Electrical power generation from renewable energy sources, such as wind energy systems, has become a crucial issue because of environmental problems and a predicted future shortage of traditional energy sources. Thus, Chapter 2 focuses on the shaft voltage analysis of stator-fed induction generators (IG) and Doubly Fed Induction Generators DFIGs in wind turbine applications. This shaft voltage analysis includes: topologies, high frequency modelling, calculation and mitigation techniques. A back-to-back AC-DC-AC converter is investigated in terms of shaft voltage generation in a DFIG. Different topologies of LC filter placement are analysed in an effort to eliminate the shaft voltage. Different capacitive couplings exist in the motor/generator structure and any change in design parameters affects the capacitive couplings. Thus, an appropriate design for AC motors should lead to the smallest possible shaft voltage. Calculation of the shaft voltage based on different capacitive couplings, and an investigation of the effects of different design parameters are discussed in Chapter 3. This is achieved through 2-D and 3-D finite element simulation and experimental analysis. End-winding parameters of the motor are also effective factors in the calculation of the shaft voltage and have not been taken into account in previous reported studies. Calculation of the end-winding capacitances is rather complex because of the diversity of end winding shapes and the complexity of their geometry. A comprehensive analysis of these capacitances has been carried out with 3-D finite element simulations and experimental studies to determine their effective design parameters. These are documented in Chapter 4. Results of this analysis show that, by choosing appropriate design parameters, it is possible to decrease the shaft voltage and resultant bearing current in the primary stage of generator/motor design without using any additional active and passive filter-based techniques. The common mode voltage is defined by a switching pattern and, by using the appropriate pattern; the common mode voltage level can be controlled. Therefore, any PWM pattern which eliminates or minimizes the common mode voltage will be an effective shaft voltage reduction technique. Thus, common mode voltage reduction of a three-phase AC motor supplied with a single-phase diode rectifier is the focus of Chapter 5. The proposed strategy is mainly based on proper utilization of the zero vectors. Multilevel inverters are also used in ASD systems which have more voltage levels and switching states, and can provide more possibilities to reduce common mode voltage. A description of common mode voltage of multilevel inverters is investigated in Chapter 6. Chapter 7 investigates the elimination techniques of the shaft voltage in a DFIG based on the methods presented in the literature by the use of simulation results. However, it could be shown that every solution to reduce the shaft voltage in DFIG systems has its own characteristics, and these have to be taken into account in determining the most effective strategy. Calculation of the capacitive coupling and electric fields between the outer and inner races and the balls at different motor speeds in symmetrical and asymmetrical shaft and balls positions is discussed in Chapter 8. The analysis is carried out using finite element simulations to determine the conditions which will increase the probability of high rates of bearing failure due to current discharges through the balls and races.
Resumo:
Network has emerged from a contempory worldwide phenomenon, culturally manifested as a consequence of globalization and the knowledge economy. It is in this context that the internet revolution has prompted a radical re-ordering of social and institutional relations and the associated structures, processes and places which support them. Within the duality of virtual space and the augmentation of traditional notions of physical place, the organizational structures pose new challenges for the design professions. Technological developments increasingly permit communication anytime and anywhere, and provide the opportunity for both synchronous and asynchronous collaboration. The resultant ecology formed through the network enterprise has resulted in an often convolted and complex world wherein designers are forced to consider the relevance and meaning of this new context. The role of technology and that of space are thus interwined in the relation between the network and the individual workplace. This paper explores a way to inform the interior desgn process for contemporary workplace environments. It reports on both theoretical and practical outcomes through an Australia-wide case study of three collaborating, yet independent business entities. It further suggests the link between workplace design and successful business innovation being realized between partnering organizations in Great Britain. Evidence presented indicates that, for architects and interior designers, the scope of the problem has widened, the depth of knowledge required to provide solutions has increased, and the rules of engagement are required to change. The ontological and epistemological positions adopted in the study enabled the spatial dimensions to be examined from both within and beyond the confines of a traditional design only viewpoint. Importantly it highlights the significance of a trans-disiplinary collaboration in dealing with the multiple layers and complexity of the contemporary social and business world, from both a research and practice perspective.
Resumo:
This paper proposes a novel peak load management scheme for rural areas. The scheme transfers certain customers onto local nonembedded generators during peak load periods to alleviate network under voltage problems. This paper develops and presents this system by way of a case study in Central Queensland, Australia. A methodology is presented for determining the best location for the nonembedded generators as well as the number of generators required to alleviate network problems. A control algorithm to transfer and reconnect customers is developed to ensure that the network voltage profile remains within specification under all plausible load conditions. Finally, simulations are presented to show the performance of the system over a typical maximum daily load profile with large stochastic load variations.
Resumo:
It is well accepted that different types of distributed architectures require different degrees of coupling. For example, in client-server and three-tier architectures, application components are generally tightly coupled, both with one another and with the underlying middleware. Meanwhile, in off-line transaction processing, grid computing and mobile applications, the degree of coupling between application components and with the underlying middleware needs to be minimized. Terms such as ‘synchronous’, ‘asynchronous’, ‘blocking’, ‘non-blocking’, ‘directed’, and ‘non-directed’ are often used to refer to the degree of coupling required by an architecture or provided by a middleware. However, these terms are used with various connotations. Although various informal definitions have been provided, there is a lack of an overarching formal framework to unambiguously communicate architectural requirements with respect to (de-)coupling. This article addresses this gap by: (i) formally defining three dimensions of (de-)coupling; (ii) relating these dimensions to existing middleware; and (iii) proposing notational elements to represent various coupling integration patterns. This article also discusses a prototype that demonstrates the feasibility of its implementation.
Resumo:
In this paper a new approach is proposed for interpreting of regional frequencies in multi machine power systems. The method uses generator aggregation and system reduction based on coherent generators in each area. The reduced system structure is able to be identified and a kalman estimator is designed for the reduced system to estimate the inter-area modes using the synchronized phasor measurement data. The proposed method is tested on a six machine, three area test system and the obtained results show the estimation of inter-area oscillations in the system with a high accuracy.
Resumo:
This paper presents the outcome of investigations and studies of the vibratioon characteristics and response of low frequency structural systems for a composite concrete steel floor plate and a reverse profiled cable tensioned foot bridge. These highly dynamic and slender structure are the engineering response to planning, aesthetic and environmental influences, but are prone to excessive and complex vibration. A number of design codes and practice guides provided information to engineers for vibration mitigation However, they are limited to very simple load function applied to a few uncoupled translational modes of excitation. Motivated by the need to address the knowledge gaps in this area, the investigations described in this paper focused on synchronous multi-modal and coupled excitation of the floor plate and footbridge with considerations for torsinal effects. The results showed the potential for adverse dynamic response from multi-modal and coupled excitation influenced by patterned loading, structure geometry, stiffness distribution, directional effects, forcing functions based on activity frequency and duration of foot contact, and modal participation. It was also shown that higher harmonics of the load frequency can excite higher modes in the composite floor structure. Such responsive behaviour is prevalent mainly in slender and lightweight construction and not in stiffer and heavier structural systems. The analytical techniques and methods used in these investigations can supplement the current limited code and best practice provisions for mitigating the impact of human induced vibrations in slender structural systems.
Resumo:
Association rule mining has contributed to many advances in the area of knowledge discovery. However, the quality of the discovered association rules is a big concern and has drawn more and more attention recently. One problem with the quality of the discovered association rules is the huge size of the extracted rule set. Often for a dataset, a huge number of rules can be extracted, but many of them can be redundant to other rules and thus useless in practice. Mining non-redundant rules is a promising approach to solve this problem. In this paper, we first propose a definition for redundancy, then propose a concise representation, called a Reliable basis, for representing non-redundant association rules. The Reliable basis contains a set of non-redundant rules which are derived using frequent closed itemsets and their generators instead of using frequent itemsets that are usually used by traditional association rule mining approaches. An important contribution of this paper is that we propose to use the certainty factor as the criterion to measure the strength of the discovered association rules. Using this criterion, we can ensure the elimination of as many redundant rules as possible without reducing the inference capacity of the remaining extracted non-redundant rules. We prove that the redundancy elimination, based on the proposed Reliable basis, does not reduce the strength of belief in the extracted rules. We also prove that all association rules, their supports and confidences, can be retrieved from the Reliable basis without accessing the dataset. Therefore the Reliable basis is a lossless representation of association rules. Experimental results show that the proposed Reliable basis can significantly reduce the number of extracted rules. We also conduct experiments on the application of association rules to the area of product recommendation. The experimental results show that the non-redundant association rules extracted using the proposed method retain the same inference capacity as the entire rule set. This result indicates that using non-redundant rules only is sufficient to solve real problems needless using the entire rule set.
Resumo:
Inspired by and featuring the poetry of Roger McGough (by permission of the author), Unlucky for Some is a spare, minimalistic work about homelessness, mental illness and class division performed entirely in slow motion. This multimedia work also utilised prerecorded and live feed video and music, and experimented with synchronous and asynchonous live and mediatised performance.
Resumo:
This thesis investigates the place of online moderation in supporting teachers to work in a system of standards-based assessment. The participants of the study were fifty middle school teachers who met online with the aim of developing consistency in their judgement decisions. Data were gathered through observation of the online meetings, interviews, surveys and the collection of artefacts. The data were viewed and analysed through sociocultural theories of learning and sociocultural theories of technology, and demonstrates how utilising these theories can add depth to understanding the added complexity of developing shared meaning of standards in an online context. The findings contribute to current understanding of standards-based assessment by examining the social moderation process as it acts to increase the reliability of judgements that are made within a standards framework. Specifically, the study investigates the opportunities afforded by conducting social moderation practices in a synchronous online context. The study explicates how the technology affects the negotiation of judgements and the development of shared meanings of assessment standards, while demonstrating how involvement in online moderation discussions can support teachers to become and belong within a practice of standards-based assessment. This research responds to a growing international interest in standards-based assessment and the use of social moderation to develop consistency in judgement decisions. Online moderation is a new practice to address these concerns on a systemic basis.
Resumo:
With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.
Resumo:
This paper proposes a comprehensive approach to the planning of distribution networks and the control of microgrids. Firstly, a Modified Discrete Particle Swarm Optimization (MDPSO) method is used to optimally plan a distribution system upgrade over a 20 year planning period. The optimization is conducted at different load levels according to the anticipated load duration curve and integrated over the system lifetime in order to minimize its total lifetime cost. Since the optimal solution contains Distributed Generators (DGs) to maximize reliability, the DG must be able to operate in islanded mode and this leads to the concept of microgrids. Thus the second part of the paper reviews some of the challenges of microgrid control in the presence of both inertial (rotating direct connected) and non-inertial (converter interfaced) DGs. More specifically enhanced control strategies based on frequency droop are proposed for DGs to improve the smooth synchronization and real power sharing minimizing transient oscillations in the microgrid. Simulation studies are presented to show the effectiveness of the control.
Resumo:
Condition monitoring of diesel engines can prevent unpredicted engine failures and the associated consequence. This paper presents an experimental study of the signal characteristics of a 4-cylinder diesel engine under various loading conditions. Acoustic emission, vibration and in-cylinder pressure signals were employed to study the effectiveness of these techniques for condition monitoring and identifying symptoms of incipient failures. An event driven synchronous averaging technique was employed to average the quasi-periodic diesel engine signal in the time domain to eliminate or minimize the effect of engine speed and amplitude variations on the analysis of condition monitoring signal. It was shown that acoustic emission (AE) is a better technique than vibration method for condition monitor of diesel engines due to its ability to produce high quality signals (i.e., excellent signal to noise ratio) in a noisy diesel engine environment. It was found that the peak amplitude of AE RMS signals correlating to the impact-like combustion related events decreases in general due to a more stable mechanical process of the engine as the loading increases. A small shift in the exhaust valve closing time was observed as the engine load increases which indicates a prolong combustion process in the cylinder (to produce more power). On the contrary, peak amplitudes of the AE RMS attributing to fuel injection increase as the loading increases. This can be explained by the increase fuel friction caused by the increase volume flow rate during the injection. Multiple AE pulses during the combustion process were identified in the study, which were generated by the piston rocking motion and the interaction between the piston and the cylinder wall. The piston rocking motion is caused by the non-uniform pressure distribution acting on the piston head as a result of the non-linear combustion process of the engine. The rocking motion ceased when the pressure in the cylinder chamber stabilized.