105 resultados para Optics and Photonics


Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is well known that a broad range of ocular anatomical and physiological parameters undergo significant diurnal variation. However, the natural diurnal variations that occur in the length of the human eye (axial length) and their underlying causes have been less well studied. Improvements in optical methods for the measurement of ocular biometrics now allow more precise and comprehensive measurements of axial length to be performed than has previously been possible. Research from animal models also suggests a link between diurnal axial length variations and longer term myopic eye growth, and that retinal image defocus can disrupt these diurnal rhythms in axial length. This research programme has examined the diurnal variations in axial length in young normal eyes, the contributing components and the influence of optical stimuli on these changes. In the first experiment, the normal pattern and consistency of the diurnal variations in axial length were examined at 10 different times (5 measurements each day, at ~ 3-hour intervals from ~ 9 am to ~ 9 pm) over 2 consecutive days on 30 young adult subjects (15 myopes, 15 emmetropes). Additionally, variations in a range of other ocular biometric measurements such as choroidal thickness, intraocular pressure, and other ocular biometrics were also explored as potential factors that may be associated with the observed variations in axial length. To investigate the potential influence of refractive error on diurnal axial length variations, the differences in the magnitude and pattern of diurnal variations in axial length between the myopic and emmetropic subjects were examined. Axial length underwent significant diurnal variation that was consistently observed over the 2 consecutive days of measurements, with the longest axial length typically occurring during the day, and the shortest at night. Significant diurnal variations were also observed in choroidal thickness, IOP and other ocular biometrics (such as central corneal thickness, anterior chamber depth and vitreous chamber depth) of the eye. Diurnal variations in vitreous chamber depth, IOP (positive associations) and choroidal thickness (negative association) were all significantly correlated with the diurnal changes in axial length. Choroidal thickness was found to fluctuate approximately in antiphase to the axial length changes, with the average timing of the longest axial length coinciding with the thinnest choroid and vice versa. There were no significant differences in the ocular diurnal variations associated with refractive error. Given that the diurnal changes in axial length could be associated with the changes in the eye’s optical quality, whether the optical quality of the eye also undergoes diurnal variation in the same cohort of young adult myopes and emmetropes over 2 consecutive days was also examined. Significant diurnal variations were observed only in the best sphere refraction (power vector M) and in the spherical aberration of the eye over two consecutive days of testing. The changes in the eyes lower and higher order ocular optics were not significantly associated with the diurnal variations in axial length and the other measured ocular biometric parameters. No significant differences were observed in the magnitude and timing of diurnal variations in lower-order and higher-order optics associated with refractive error. Since the small natural fluctuations in the eye’s optical quality did not appear to be sufficient to influence the natural diurnal fluctuations in ocular biometric parameters, in the next experiment, the influence of monocular myopic defocus (+1.50 DS) upon the normal diurnal variations in axial length and choroidal thickness of young adult emmetropic human subjects (n=13) imposed over a 12 hour period was examined. A series of axial length and choroidal thickness measurements (collected at ~3 hourly intervals, with the first measurement at ~9 am and the final measurement at ~9 pm) were obtained over three consecutive days. The natural diurnal rhythms (Day 1, no defocus), diurnal rhythms with monocular myopic defocus (Day 2, +1.50 DS spectacle lens over the right eye), and the recovery from any defocus induced changes (Day 3, no defocus) were examined. Significant diurnal variations over the course of the day were observed in both axial length and choroidal thickness on each of the three measurement days. The introduction of monocular myopic defocus led to significant reductions in the mean amplitude of diurnal change, and phase shifts in the peak timing of the diurnal rhythms in axial length and choroidal thickness. These defocus induced changes were found to be transient in nature and returned to normal the day following removal of the defocus. To further investigate the influence of optical stimuli on human diurnal rhythms, in the final experiment, the influence of monocular hyperopic defocus on the normal diurnal rhythms in axial length and choroidal thickness was examined in young adult emmetropic subjects (n=15). Similar to the previous experiment, the natural diurnal rhythms (Day 1, no defocus), diurnal rhythms with monocular hyperopic defocus (Day 2, -2.00 DS spectacle lens over the right eye), and the recovery from any defocus induced changes (Day 3, no defocus) were examined over three consecutive days. Both axial length and choroidal thickness underwent significant diurnal variations on each of the three days. The introduction of monocular hyperopic defocus resulted in a significant increase in the amplitude of diurnal change, but no change in the peak timing of diurnal rhythms in both parameters. The ocular changes associated with hyperopic defocus returned to normal, the day following removal of the defocus. This research has shown that axial length undergoes significant diurnal variation in young adult human eyes, and has shown that the natural diurnal variations in choroidal thickness and IOP are significantly associated, and may underlie these diurnal fluctuations in axial length. This work also demonstrated for the first time that exposing young human eyes to monocular myopic and hyperopic defocus leads to a significant disruption in the normal diurnal rhythms of axial length and choroidal thickness. These changes in axial length with defocus may reflect underlying mechanisms in the human eye that are involved in the regulation of longer term eye growth.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: In animal models hemi-field deprivation results in localised, graded vitreous chamber elongation and presumably deprivation induced localised changes in retinal processing. The aim of this research was to determine if there are variations in ERG responses across the retina in normal chick eyes and to examine the effect of hemi-field and full-field deprivation on ERG responses across the retina and at earlier times than have previously been examined electrophysiologically. Methods: Chicks were either untreated, wore monocular full-diffusers or half-diffusers (depriving nasal retina) (n = 6-8 each group) from day 8. mfERG responses were measured using the VERIS mfERG system across the central 18.2º× 16.7º (H × V) field. The stimulus consisted of 61 unscaled hexagons with each hexagon modulated between black and white according to a pseudorandom binary m-sequence. The mfERG was measured on day 12 in untreated chicks, following 4 days of hemi-field diffuser wear, and 2, 48 and 96 h after application of full-field diffusers. Results: The ERG response of untreated chick eyes did not vary across the measured field; there was no effect of retinal location on the N1-P1 amplitude (p = 0.108) or on P1 implicit time (p > 0.05). This finding is consistent with retinal ganglion cell density of the chick varying by only a factor of two across the entire retina. Half-diffusers produced a ramped retina and a graded effect of negative lens correction (p < 0.0001); changes in retinal processing were localized. The untreated retina showed increasing complexity of the ERG waveform with development; form-deprivation prevented the increasing complexity of the response at the 2, 48 and 96 h measurement times and produced alterations in response timing. Conclusions: Form-deprivation and its concomitant loss of image contrast and high spatial frequency images prevented development of the ERG responses, consistent with a disruption of development of retinal feedback systems. The characterisation of ERG responses in normal and deprived chick eyes across the retina allows the assessment of concurrent visual and retinal manipulations in this model. (Ophthalmic & Physiological Optics © 2013 The College of Optometrists.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose/aim Myopia incidence is increasing around the world. Myopisation is considered to be caused by a variety of factors. One consideration is whether higher-order aberrations (HOA) influence myopisation. More knowledge of optics in anisometropic eyes might give further insight into the development of refractive error. Materials and methods To analyse the possible influence of HOA on refractive error development, we compared HOA between anisometropes and isometropes. We analysed HOA up to the 4th order for both eyes of 20 anisometropes (mean age: 43 ± 17 years) and 20 isometropes (mean age: 33 ±17 years). HOA were measured with the Shack-Hartman i.Profiler (Carl Zeiss, Germany) and were recalculated for a 4 mm pupil. Mean spherical equivalent (MSE) was based on the subjective refraction. Anisometropia was defined as ≥1D interocular difference in MSE. The mean absolute differences between right and left eyes in spherical equivalent were 0.28 ± 0.21 D in the isometropic group and 2.81 ± 2.04 D in the anisometropic group. Interocular differences in HOA were compared with the interocular difference in MSE using correlations. Results For isometropes oblique trefoil, vertical coma, horizontal coma and spherical aberration showed significant correlations between the two eyes. In anisometropes all analysed higher-order aberrations correlated significantly between the two eyes except oblique secondary astigmatism and secondary astigmatism. When analysing anisometropes and isometropes separately, no significant correlations were found between interocular differences of higher-order aberrations and MSE. For isometropes and anisometropes combined, tetrafoil correlated significantly with MSE in left eyes. Conclusions The present study could not show that interocular differences of higher-order aberrations increase with increasing interocular difference in MSE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parsons' Diseases of the Eye, first published in 1907, is one of the foundation texts of modern ophthalmology. It has seen a new edition at approximately 5-year intervals throughout the century. This latest edition incorporates developments that have taken place within the specialty since the 1984 impression, but remains in a virtually unchanged format...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To investigate the differences between and variations across time in corneal topography and ocular wavefront aberrations in young Singaporean myopes and emmetropes. Methods We used a videokeratoscope and wavefront sensor to measure the ocular surface topography and wavefront aberrations of the total eye optics in the morning, mid-day and late afternoon on two separate days. Topography data were used to derive the corneal surface wavefront aberrations. Both the corneal and total wavefronts were analysed up to the 4th radial order of the Zernike polynomial expansion, and were centred on the entrance pupil (5 mm). The participants included 12 young progressing myopes, 13 young stable myopes and 15 young age-matched emmetropes. Results For all subjects considered together there were significant changes in some of the aberrations terms across the day, such as spherical aberration ( ) and vertical coma ( ) (repeated measures ANOVA, p<0.05). The magnitude of positive spherical aberration ( ) was significantly lower in the progressing myope group than that of the stable myopes (p=0.04) and emmetrope group (p=0.02). There were also significant interactions between refractive group and time of day for with/against-the-rule astigmatism ( ). Significantly lower 4th order RMS of ocular wavefront aberrations were found in the progressing myope group compared with the stable myopes and emmetropes (p<0.01). Conclusions These differences and variations in the corneal and total aberrations may have significance for our understanding of refractive error development and for clinical applications requiring accurate wavefront measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To investigate changes in the characteristics of the corneal optics, total optics, anterior biometrics and axial length of the eye during a near task, in downward gaze, over 10 min. METHODS Ten emmetropes (mean - 0.14 ± 0.24 DS) and 10 myopes (mean - 2.26 ± 1.42 DS) aged from 18 to 30 years were recruited. To measure ocular biometrics and corneal topography in downward gaze, an optical biometer (Lenstar LS900) and a rotating Scheimpflug camera (Pentacam HR) were inclined on a custom built, height and tilt adjustable table. The total optics of the eye were measured in downward gaze with binocular fixation using a modified Shack-Hartmann wavefront sensor. Initially, subjects performed a distance viewing task at primary gaze for 10 min to provide a "wash-out" period for prior visual tasks. A distance task (watching video at 6 m) in downward gaze (25°) and a near task (watching video on a portable LCD screen with 2.5 D accommodation demand) in primary gaze and 25°downward gaze were then carried out, each for 10 min in a randomized order. During measurements, in dichoptic view, a Maltese cross was fixated with the right (untested) eye and the instrument’s fixation target was fixated with the subject’s tested left eye. Immediately after (0 min), 5 and 10 min from the commencement of each trial, measurements of ocular parameters were acquired in downward gaze. RESULTS Axial length exhibited a significant increase with downward gaze and accommodation over time (p<0.05). The greatest axial elongation was observed in downward gaze with 2.5 D accommodation after 10 min (mean change from baseline 23±3 µm). Downward gaze also caused greater changes in anterior chamber depth (ACD) and lens thickness (LT) with accommodation (ACD mean change -163±12µm at 10 min; LT mean change 173±17 µm at 10 min) compared to primary gaze with accommodation (ACD mean change -138±12µm at 10 min; LT mean change 131±15 µm at 10 min). Both corneal power and total ocular power changed by a small but significant amount with downward gaze (p<0.05), resulting in a myopic shift (~0.10 D) in the spherical power of the eye compared with primary gaze. CONCLUSION The axial length, anterior biometrics and ocular refraction change significantly with accommodation in downward gaze as a function of time. These findings provide new insights into the optical and bio-mechanical changes of the eye during typical near tasks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the effects of handling and fixation processes on the two-photon fluorescence spectroscopy of endogenous fluorophors in mouse skeletal muscle. The skeletal muscle was handled in one of two ways: either sectioned without storage or sectioned following storage in a freezer. The two-photon fluorescence spectra measured for different storage or fixation periods show a differential among those samples that were stored in water or were fixed either in formalin or methanol. The spectroscopic results indicate that formalin was the least disruptive fixative, having only a weak effect on the two-photon fluorescence spectroscopy of muscle tissue, whereas methanol had a significant influence on one of the autofluorescence peaks. The two handling processes yielded similar spectral information, indicating no different effects between them.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on its enticing properties, graphene has been envisioned with applications in the area of electronics, photonics, sensors, bioapplications and others. To facilitate various applications, doping has been frequently used to manipulate the properties of graphene. Despite a number of studies conducted on doped graphene regarding its electrical and chemical properties, the impact of doping on the mechanical properties of graphene has been rarely discussed. A systematic study of the vibrational properties of graphene doped with nitrogen and boron is performed by means of a molecular dynamics simulation. The influence from different density or species of dopants has been assessed. It is found that the impacts on the quality factor, Q, resulting from different densities of dopants vary greatly, while the influence on the resonance frequency is insignificant. The reduction of the resonance frequency caused by doping with boron only is larger than the reduction caused by doping with both boron and nitrogen. This study gives a fundamental understanding of the resonance of graphene with different dopants, which may benefit their application as resonators.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We demonstrate the first biaxial fiber Bragg grating (FBG) accelerometer using axial and transverse forces. An inertial object is fixed at the middle of two FBGs inscribed in one fiber. The difference between the resonant wavelengths of the two FBGs can distinguish the acceleration in the axial direction, while being insensitive in the transverse direction. The average of the resonant wavelengths of the two FBGs can distinguish the acceleration in the transverse direction, while being insensitive in the axial direction. In the experiments, when the transverse direction was vertical, the crest-to-trough sensitivity at 5 Hz and resonant frequency of the average were 0.545 nm/g and 34.42 Hz, respectively. When the axial direction was vertical, those of the difference were 0.0454 nm/g and 900 Hz, respectively. For each FBG, the crest-to-trough sensitivity at 5 Hz and resonant frequency in the transverse/vertical direction were 24 and 1/26 times those in the axial/vertical direction, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis has systemically investigated the possibility of improving one type of optical fiber sensors by using a novel mechanism. Many parameters of the sensor have been improved, and one outcome of this innovation is that civil structures, such as bridges and high-rise buildings, may be operated more safely and used longer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Older adults have increased visual impairment, including refractive blur from presbyopic multifocal spectacle corrections, and are less able to extract visual information from the environment to plan and execute appropriate stepping actions; these factors may collectively contribute to their higher risk of falls. The aim of this study was to examine the effect of refractive blur and target visibility on the stepping accuracy and visuomotor stepping strategies of older adults during a precision stepping task. Methods: Ten healthy, visually normal older adults (mean age 69.4 ± 5.2 years) walked up and down a 20 m indoor corridor stepping onto selected high and low-contrast targets while viewing under three visual conditions: best-corrected vision, +2.00 DS and +3.00 DS blur; the order of blur conditions was randomised between participants. Stepping accuracy and gaze behaviours were recorded using an eyetracker and a secondary hand-held camera. Results: Older adults made significantly more stepping errors with increasing levels of blur, particularly exhibiting under-stepping (stepping more posteriorly) onto the targets (p<0.05), while visuomotor stepping strategies did not significantly alter. Stepping errors were also significantly greater for the low compared to the high contrast targets and differences in visuomotor stepping strategies were found, including increased duration of gaze and increased interval between gaze onset and initiation of the leg swing when stepping onto the low contrast targets. Conclusions: These findings highlight that stepping accuracy is reduced for low visibility targets, and for high levels of refractive blur at levels typically present in multifocal spectacle corrections, despite significant changes in some of the visuomotor stepping strategies. These findings highlight the importance of maximising the contrast of objects in the environment, and may help explain why older adults wearing multifocal spectacle corrections exhibit an increased risk of falling.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We studied the effect of rod–cone interactions on mesopic visual reaction time (RT). Rod and cone photoreceptor excitations were independently controlled using a four-primary photostimulator. It was observed that (1) lateral rod–cone interactions increase the cone-mediated RTs; (2) the rod–cone interactions are strongest when rod sensitivity is maximal in a dark surround, but weaker with increased rod activity in a light surround; and (3) the presence of a dark surround nonselectively increased the mean and variability of chromatic (+L-M, S-cone) and luminance (L+M+S) RTs independent of the level of rod activity. The results demonstrate that lateral rod–cone interactions must be considered when deriving mesopic luminous efficiency using RT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose To quantify the effects of driver age on night-time pedestrian conspicuity, and to determine whether individual differences in visual performance can predict drivers' ability to recognise pedestrians at night. Methods Participants were 32 visually normal drivers (20 younger: M = 24.4 years ± 6.4 years; 12 older: M = 72.0 years ± 5.0 years). Visual performance was measured in a laboratory-based testing session including visual acuity, contrast sensitivity, motion sensitivity and the useful field of view. Night-time pedestrian recognition distances were recorded while participants drove an instrumented vehicle along a closed road course at night; to increase the workload of drivers, auditory and visual distracter tasks were presented for some of the laps. Pedestrians walked in place, sideways to the oncoming vehicles, and wore either a standard high visibility reflective vest or reflective tape positioned on the movable joints (biological motion). Results Driver age and pedestrian clothing significantly (p < 0.05) affected the distance at which the drivers first responded to the pedestrians. Older drivers recognised pedestrians at approximately half the distance of the younger drivers and pedestrians were recognised more often and at longer distances when they wore a biological motion reflective clothing configuration than when they wore a reflective vest. Motion sensitivity was an independent predictor of pedestrian recognition distance, even when controlling for driver age. Conclusions The night-time pedestrian recognition capacity of older drivers was significantly worse than that of younger drivers. The distance at which drivers first recognised pedestrians at night was best predicted by a test of motion sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The population is ageing. Globally, the number of older adults (aged 60 years or over) is expected to more than double, from 841 million people in 2013 to more than 2 billion in 2050.1 In light of the increasing size of the older adult population, there is a pressing need to better identify the nature of, and mechanisms underlying, age-related vision impairment and the functional impact it has on the performance of everyday activities in older adults. The content of this feature issue reflects the diversity of research currently being undertaken on the topic of the ageing visual system and the important visual challenges that this presents for our ageing patient population. The scope is broad and includes topics relating to three main related themes: 1) The treatment of age-related ocular disorders and diseases and their consequences, including presbyopia and AMD; 2) The impact of age-related visual changes on everyday activities in older people, including mobility, driving and falls, and; 3) The interaction of age-related visual impairments and other age-related impairments including hearing and cognitive changes.