Through-focus performance with multifocal contact lenses : effect of binocularity, pupil diameter and inherent ocular aberrations


Autoria(s): Plainis, Sotiris; Ntzilepis, George; Atchison, David A.; Charman, W. Neil
Data(s)

2013

Resumo

Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/64948/

Publicador

John Wiley & Sons, Inc

Relação

http://eprints.qut.edu.au/64948/2/64948.pdf

DOI:10.1111/opo.12004

Plainis, Sotiris, Ntzilepis, George, Atchison, David A., & Charman, W. Neil (2013) Through-focus performance with multifocal contact lenses : effect of binocularity, pupil diameter and inherent ocular aberrations. Ophthalmic and Physiological Optics, 33(1), pp. 42-50.

Direitos

Copyright 2013 The College of Optometrists

Fonte

Faculty of Health; Institute of Health and Biomedical Innovation; School of Optometry & Vision Science

Palavras-Chave #111303 Vision Science #multifocal contact lenses #visual acuity #depth-of-focus #spherical aberration
Tipo

Journal Article