201 resultados para Quantum Error-correction
Resumo:
This work investigates the computer modelling of the photochemical formation of smog products such as ozone and aerosol, in a system containing toluene, NOx and water vapour. In particular, the problem of modelling this process in the Commonwealth Scientific and Industrial Research Organization (CSIRO) smog chambers, which utilize outdoor exposure, is addressed. The primary requirement for such modelling is a knowledge of the photolytic rate coefficients. Photolytic rate coefficients of species other than N02 are often related to JNo2 (rate coefficient for the photolysis ofN02) by a simple factor, but for outdoor chambers, this method is prone to error as the diurnal profiles may not be similar in shape. Three methods for the calculation of diurnal JNo2 are investigated. The most suitable method for incorporation into a general model, is found to be one which determines the photolytic rate coefficients for N02, as well as several other species, from actinic flux, absorption cross section and quantum yields. A computer model was developed, based on this method, to calculate in-chamber photolysis rate coefficients for the CSIRO smog chambers, in which ex-chamber rate coefficients are adjusted by accounting for variation in light intensity by transmittance through the Teflon walls, albedo from the chamber floor and radiation attenuation due to clouds. The photochemical formation of secondary aerosol is investigated in a series of toluene-NOx experiments, which were performed in the CSIRO smog chambers. Three stages of aerosol formation, in plots of total particulate volume versus time, are identified: a delay period in which no significant mass of aerosol is formed, a regime of rapid aerosol formation (regime 1) and a second regime of slowed aerosol formation (regime 2). Two models are presented which were developed from the experimental data. One model is empirically based on observations of discrete stages of aerosol formation and readily allows aerosol growth profiles to be calculated. The second model is based on an adaptation of published toluene photooxidation mechanisms and provides some chemical information about the oxidation products. Both models compare favorably against the experimental data. The gross effects of precursor concentrations (toluene, NOx and H20) and ambient conditions (temperature, photolysis rate) on the formation of secondary aerosol are also investigated, primarily using the mechanism model. An increase in [NOx]o results in increased delay time, rate of aerosol formation in regime 1 and volume of aerosol formed in regime 1. This is due to increased formation of dinitrocresol and furanone products. An increase in toluene results in a decrease in the delay time and an increase in the rate of aerosol formation in regime 1, due to enhanced reactivity from the toluene products, such as the radicals from the photolysis of benzaldehyde. Water vapor has very little effect on the formation of aerosol volume, except that rates are slightly increased due to more OH radicals from reaction with 0(1D) from ozone photolysis. Increased temperature results in increased volume of aerosol formed in regime 1 (increased dinitrocresol formation), while increased photolysis rate results in increased rate of aerosol formation in regime 1. Both the rate and volume of aerosol formed in regime 2 are increased by increased temperature or photolysis rate. Both models indicate that the yield of secondary particulates from hydrocarbons (mass concentration aerosol formed/mass concentration hydrocarbon precursor) is proportional to the ratio [NOx]0/[hydrocarbon]0
Resumo:
An algorithm based on the concept of combining Kalman filter and Least Error Square (LES) techniques is proposed in this paper. The algorithm is intended to estimate signal attributes like amplitude, frequency and phase angle in the online mode. This technique can be used in protection relays, digital AVRs, DGs, DSTATCOMs, FACTS and other power electronics applications. The Kalman filter is modified to operate on a fictitious input signal and provides precise estimation results insensitive to noise and other disturbances. At the same time, the LES system has been arranged to operate in critical transient cases to compensate the delay and inaccuracy identified because of the response of the standard Kalman filter. Practical considerations such as the effect of noise, higher order harmonics, and computational issues of the algorithm are considered and tested in the paper. Several computer simulations and a laboratory test are presented to highlight the usefulness of the proposed method. Simulation results show that the proposed technique can simultaneously estimate the signal attributes, even if it is highly distorted due to the presence of non-linear loads and noise.
Resumo:
Measures and theories of information abound, but there are few formalised methods for treating the contextuality that can manifest in different information systems. Quantum theory provides one possible formalism for treating information in context. This paper introduces a quantum-like model of the human mental lexicon, and shows one set of recent experimental data suggesting that concept combinations can indeed behave non-separably. There is some reason to believe that the human mental lexicon displays entanglement.
Resumo:
Purpose: To investigate the influence of accommodation upon axial length (and a comprehensive range of ocular biometric parameters), in populations of young adult myopic and emmetropic subjects. Methods: Forty young adult subjects had ocular biometry measured utilizing a non-contact optical biometer (Lenstar LS 900) based upon the principle of optical low coherence reflectometry, under three different accommodation demands (0 D, 3 D and 6 D). Subjects were classified as emmetropes (n=19) or myopes (n=21) based upon their spherical equivalent refraction (mean emmetropic refraction -0.05 ± 0.27DS and mean myopic refraction -1.82 ± 0.84 DS). Results: Axial length changed significantly with accommodation, with a mean increase of 11.9 ± 12.3 µm and 24.1 ± 22.7 µm for the 3 D and 6 D accommodation stimuli respectively. A significant axial elongation associated with accommodation was still evident even following correction of the axial length data for potential error due to lens thickness change. The mean ‘corrected’ increase in axial length was 5.2 ± 11.2 µm, and 7.4 ± 18.9 µm for the 3 D and 6 D stimuli respectively. There was no significant difference between the myopic and emmetropic populations in terms of the magnitude of change in axial length with accommodation, regardless of whether the data were corrected or not. A number of other ocular biometric parameters, such as anterior chamber depth, lens thickness and vitreous chamber depth also exhibited significant change with accommodation. The myopic and emmetropic populations also exhibited no significant difference in the magnitude of change in these parameters with accommodation. Conclusions: The eye undergoes a significant axial elongation associated with a brief period of accommodation, and the magnitude of this change in eye length increases for larger accommodation demands, however there is no significant difference in the magnitude of eye elongation in myopic and emmetropic subjects.
Resumo:
Prospective clinical case series of 100 patients receiving thoracoscopic anterior scoliosis correction surgery. The objective was to evaluate the relationship between clinical outcomes of thoracoscopic anterior scoliosis surgery and deformity correction using the Scoliosis Research Society (SRS) outcomes instrument questionnaire. The surgical treatment of scoliosis is quantitatively assessed in the clinic using radiographic measures of deformity correction, as well as the rib hump, but it is important to understand the extent to which these quantitative measures correlate with self-reported improvements in patients’ quality of life following surgery. A series of 100 consecutive adolescent idiopathic scoliosis patients received a single anterior rod via a thoracoscopic approach at the Mater Children’s Hospital, Brisbane, Australia. Patients completed SRS outcomes questionnaires pre-operatively and at 24 months post-operatively. There were 94 females and 6 males with a mean age of 16.1 years. The mean Cobb angle improved from 52º pre-operatively to 25º post-operatively (52%) and the mean rib hump improved from 16º to 8º (51%). The mean total SRS score for the cohort was 99.4/120. None of the deformity related parameters in the multiple regression were significant. However, patients with the lowest post-operative major Cobb angles reported significantly higher SRS scores than those with the highest post-operative Cobb angles, but there was no difference on the basis of rib hump correction. There were no significant differences between patients with either rod fractures or screw-related complications compared to those without complications.
Resumo:
Purpose. To investigate the effect of various presbyopic vision corrections on nighttime driving performance on a closed-road driving circuit. Methods. Participants were 11 presbyopes (mean age, 57.3 ± 5.8 years), with a mean best sphere distance refractive error of R+0.23±1.53 DS and L+0.20±1.50 DS, whose only experience of wearing presbyopic vision correction was reading spectacles. The study involved a repeated-measures design by which a participant's nighttime driving performance was assessed on a closed-road circuit while wearing each of four power-matched vision corrections. These included single-vision distance lenses (SV), progressive-addition spectacle lenses (PAL), monovision contact lenses (MV), and multifocal contact lenses (MTF CL) worn in a randomized order. Measures included low-contrast road hazard detection and avoidance, road sign and near target recognition, lane-keeping, driving time, and legibility distance for street signs. Eye movement data (fixation duration and number of fixations) were also recorded. Results. Street sign legibility distances were shorter when wearing MV and MTF CL than SV and PAL (P < 0.001), and participants drove more slowly with MTF CL than with PALs (P = 0.048). Wearing SV resulted in more errors (P < 0.001) and in more (P = 0.002) and longer (P < 0.001) fixations when responding to near targets. Fixation duration was also longer when viewing distant signs with MTF CL than with PAL (P = 0.031). Conclusions. Presbyopic vision corrections worn by naive, unadapted wearers affected nighttime driving. Overall, spectacle corrections (PAL and SV) performed well for distance driving tasks, but SV negatively affected viewing near dashboard targets. MTF CL resulted in the shortest legibility distance for street signs and longer fixation times.
Resumo:
The paper provides an assessment of the performance of commercial Real Time Kinematic (RTK) systems over longer than recommended inter-station distances. The experiments were set up to test and analyse solutions from the i-MAX, MAX and VRS systems being operated with three triangle shaped network cells, each having an average inter-station distance of 69km, 118km and 166km. The performance characteristics appraised included initialization success rate, initialization time, RTK position accuracy and availability, ambiguity resolution risk and RTK integrity risk in order to provide a wider perspective of the performance of the testing systems. ----- ----- The results showed that the performances of all network RTK solutions assessed were affected by the increase in the inter-station distances to similar degrees. The MAX solution achieved the highest initialization success rate of 96.6% on average, albeit with a longer initialisation time. Two VRS approaches achieved lower initialization success rate of 80% over the large triangle. In terms of RTK positioning accuracy after successful initialisation, the results indicated a good agreement between the actual error growth in both horizontal and vertical components and the accuracy specified in the RMS and part per million (ppm) values by the manufacturers. ----- ----- Additionally, the VRS approaches performed better than the MAX and i-MAX when being tested under the standard triangle network with a mean inter-station distance of 69km. However as the inter-station distance increases, the network RTK software may fail to generate VRS correction and then may turn to operate in the nearest single-base RTK (or RAW) mode. The position uncertainty reached beyond 2 meters occasionally, showing that the RTK rover software was using an incorrect ambiguity fixed solution to estimate the rover position rather than automatically dropping back to using an ambiguity float solution. Results identified that the risk of incorrectly resolving ambiguities reached 18%, 20%, 13% and 25% for i-MAX, MAX, Leica VRS and Trimble VRS respectively when operating over the large triangle network. Additionally, the Coordinate Quality indicator values given by the Leica GX1230 GG rover receiver tended to be over-optimistic and not functioning well with the identification of incorrectly fixed integer ambiguity solutions. In summary, this independent assessment has identified some problems and failures that can occur in all of the systems tested, especially when being pushed beyond the recommended limits. While such failures are expected, they can offer useful insights into where users should be wary and how manufacturers might improve their products. The results also demonstrate that integrity monitoring of RTK solutions is indeed necessary for precision applications, thus deserving serious attention from researchers and system providers.
Resumo:
Gay community media functions as a system with three nodes, in which the flows of information and capital theoretically benefit all parties: the gay community gains a sense of cohesion and citizenship through media; the gay media outlets profit from advertisers’ capital; and advertisers recoup their investments in lucrative ‘pink dollar’ revenue. But if a necessary corollary of all communication systems is error or noise, where—and what—are the errors in this system? In this paper we argue that the ‘error’ in the gay media system is Queerness, and that the gay media system ejects (in a process of Kristevan abjection) these Queer identities in order to function successfully. We examine the ways in which Queer identities are excluded from representation in such media through a discourse and content analysis of The Sydney Star Observer (Australia’s largest gay and lesbian paper). First, we analyse the way Queer bodies are excluded from the discourses that construct and reinforce both the ideal gay male body and the notions of homosexual essence required for that body to be meaningful. We then argue that abject Queerness returns in the SSO’s discourses of public health through the conspicuous absence of the AIDS-inflicted body (which we read as the epitome of the abject Queer), since this absence paradoxically conjures up a trace of that which the system tries to expel. We conclude by arguing that because the ‘Queer error’ is integral to the SSO, gay community media should practise a politics of Queer inclusion rather than exclusion.
Resumo:
The depth of focus (DOF) can be defined as the variation in image distance of a lens or an optical system which can be tolerated without incurring an objectionable lack of sharpness of focus. The DOF of the human eye serves a mechanism of blur tolerance. As long as the target image remains within the depth of focus in the image space, the eye will still perceive the image as being clear. A large DOF is especially important for presbyopic patients with partial or complete loss of accommodation (presbyopia), since this helps them to obtain an acceptable retinal image when viewing a target moving through a range of near to intermediate distances. The aim of this research was to investigate the DOF of the human eye and its association with the natural wavefront aberrations, and how higher order aberrations (HOAs) can be used to expand the DOF, in particular by inducing spherical aberrations ( 0 4 Z and 0 6 Z ). The depth of focus of the human eye can be measured using a variety of subjective and objective methods. Subjective measurements based on a Badal optical system have been widely adopted, through which the retinal image size can be kept constant. In such measurements, the subject.s tested eye is normally cyclopleged. Objective methods without the need of cycloplegia are also used, where the eye.s accommodative response is continuously monitored. Generally, the DOF measured by subjective methods are slightly larger than those measured objectively. In recent years, methods have also been developed to estimate DOF from retinal image quality metrics (IQMs) derived from the ocular wavefront aberrations. In such methods, the DOF is defined as the range of defocus error that degrades the retinal image quality calculated from the IQMs to a certain level of the possible maximum value. In this study, the effect of different amounts of HOAs on the DOF was theoretically evaluated by modelling and comparing the DOF of subjects from four different clinical groups, including young emmetropes (20 subjects), young myopes (19 subjects), presbyopes (32 subjects) and keratoconics (35 subjects). A novel IQM-based through-focus algorithm was developed to theoretically predict the DOF of subjects with their natural HOAs. Additional primary spherical aberration ( 0 4 Z ) was also induced in the wavefronts of myopes and presbyopes to simulate the effect of myopic refractive correction (e.g. LASIK) and presbyopic correction (e.g. progressive power IOL) on the subject.s DOF. Larger amounts of HOAs were found to lead to greater values of predicted DOF. The introduction of primary spherical aberration was found to provide moderate increase of DOF while slightly deteriorating the image quality at the same time. The predicted DOF was also affected by the IQMs and the threshold level adopted. We then investigated the influence of the chosen threshold level of the IQMs on the predicted DOF, and how it relates to the subjectively measured DOF. The subjective DOF was measured in a group of 17 normal subjects, and we used through-focus visual Strehl ratio based on optical transfer function (VSOTF) derived from their wavefront aberrations as the IQM to estimate the DOF. The results allowed comparison of the subjective DOF with the estimated DOF and determination of a threshold level for DOF estimation. Significant correlation was found between the subject.s estimated threshold level for the estimated DOF and HOA RMS (Pearson.s r=0.88, p<0.001). The linear correlation can be used to estimate the threshold level for each individual subject, subsequently leading to a method for estimating individual.s DOF from a single measurement of their wavefront aberrations. A subsequent study was conducted to investigate the DOF of keratoconic subjects. Significant increases of the level of HOAs, including spherical aberration, coma and trefoil, can be observed in keratoconic eyes. This population of subjects provides an opportunity to study the influence of these HOAs on DOF. It was also expected that the asymmetric aberrations (coma and trefoil) in the keratoconic eye could interact with defocus to cause regional blur of the target. A dual-Badal-channel optical system with a star-pattern target was used to measure the subjective DOF in 10 keratoconic eyes and compared to those from a group of 10 normal subjects. The DOF measured in keratoconic eyes was significantly larger than that in normal eyes. However there was not a strong correlation between the large amount of HOA RMS and DOF in keratoconic eyes. Among all HOA terms, spherical aberration was found to be the only HOA that helped to significantly increase the DOF in the studied keratoconic subjects. Through the first three studies, a comprehensive understanding of DOF and its association to the HOAs in the human eye had been achieved. An adaptive optics system was then designed and constructed. The system was capable of measuring and altering the wavefront aberrations in the subject.s eye and measuring the resulting DOF under the influence of different combination of HOAs. Using the AO system, we investigated the concept of extending the DOF through optimized combinations of 0 4 Z and 0 6 Z . Systematic introduction of a targeted amount of both 0 4 Z and 0 6 Z was found to significantly improve the DOF of healthy subjects. The use of wavefront combinations of 0 4 Z and 0 6 Z with opposite signs can further expand the DOF, rather than using 0 4 Z or 0 6 Z alone. The optimal wavefront combinations to expand the DOF were estimated using the ratio of increase in DOF and loss of retinal image quality defined by VSOTF. In the experiment, the optimal combinations of 0 4 Z and 0 6 Z were found to provide a better balance of DOF expansion and relatively smaller decreases in VA. Therefore, the optimal combinations of 0 4 Z and 0 6 Z provides a more efficient method to expand the DOF rather than 0 4 Z or 0 6 Z alone. This PhD research has shown that there is a positive correlation between the DOF and the eye.s wavefront aberrations. More aberrated eyes generally have a larger DOF. The association of DOF and the natural HOAs in normal subjects can be quantified, which allows the estimation of DOF directly from the ocular wavefront aberration. Among the Zernike HOA terms, spherical aberrations ( 0 4 Z and 0 6 Z ) were found to improve the DOF. Certain combinations of 0 4 Z and 0 6 Z provide a more effective method to expand DOF than using 0 4 Z or 0 6 Z alone, and this could be useful in the optimal design of presbyopic optical corrections such as multifocal contact lenses, intraocular lenses and laser corneal surgeries.
Resumo:
Similarity solutions for flow over an impermeable, non-linearly (quadratic) stretching sheet were studied recently by Raptis and Perdikis (Int. J. Non-linear Mech. 41 (2006) 527–529) using a stream function of the form ψ=αxf(η)+βx2g(η). A fundamental error in their problem formulation is pointed out. On correction, it is shown that similarity solutions do not exist for this choice of ψ
Resumo:
Regardless of technology benefits, safety planners still face difficulties explaining errors related to the use of different technologies and evaluating how the errors impact the performance of safety decision making. This paper presents a preliminary error impact analysis testbed to model object identification and tracking errors caused by image-based devices and algorithms and to analyze the impact of the errors for spatial safety assessment of earthmoving and surface mining activities. More specifically, this research designed a testbed to model workspaces for earthmoving operations, to simulate safety-related violations, and to apply different object identification and tracking errors on the data collected and processed for spatial safety assessment. Three different cases were analyzed based on actual earthmoving operations conducted at a limestone quarry. Using the testbed, the impacts of the errors were investigated for the safety planning purpose.
Resumo:
Background: Fusionless scoliosis surgery is an early-stage treatment for idiopathic scoliosis which claims potential advantages over current fusion-based surgical procedures. Anterior vertebral stapling using a shape memory alloy staple is one such approach. Despite increasing interest in this technique, little is known about the effects on the spine following insertion, or the mechanism of action of the staple. The purpose of this study was to investigate the biomechanical consequences of staple insertion in the anterior thoracic spine, using in vitro experiments on an immature bovine model. Methods: Individual calf spine thoracic motion segments were tested in flexion, extension, lateral bending and axial rotation. Changes in motion segment rotational stiffness following staple insertion were measured on a series of 14 specimens. Strain gauges were attached to three of the staples in the series to measure forces transmitted through the staple during loading. A micro-CT scan of a single specimen was performed after loading to qualitatively examine damage to the vertebral bone caused by the staple. Findings: Small but statistically significant decreases in bending stiffness occurred in flexion,extension, lateral bending away from the staple, and axial rotation away from the staple. Each strain-gauged staple showed a baseline compressive loading following insertion which was seen to gradually decrease during testing. Post-test micro-CT showed substantial bone and growth plate damage near the staple. Interpretation: Based on our findings it is possible that growth modulation following staple insertion is due to tissue damage rather than sustained mechanical compression of the motion segment.
Resumo:
Introduction. Surgical treatment of scoliosis is assessed in the spine clinic by the surgeon making numerous measurements on X-Rays as well as the rib hump. But it is important to understand which of these measures correlate with self-reported improvements in patients’ quality of life following surgery. The objective of this study was to examine the relationship between patient satisfaction after thoracoscopic (keyhole) anterior scoliosis surgery and standard deformity correction measures using the Scoliosis Research Society (SRS) adolescent questionnaire. Methods. A series of 100 consecutive adolescent idiopathic scoliosis patients received a single anterior rod via a keyhole approach at the Mater Children’s Hospital, Brisbane. Patients completed SRS outcomes questionnaires before surgery and again at 24 months after surgery. Multiple regression and t-tests were used to investigate the relationship between SRS scores and deformity correction achieved after surgery. Results. There were 94 females and 6 males with a mean age of 16.1 years. The mean Cobb angle improved from 52º pre-operatively to 21º for the instrumented levels post-operatively (59% correction) and the mean rib hump improved from 16º to 8º (51% correction). The mean total SRS score for the cohort was 99.4/120 which indicated a high level of satisfaction with the results of their scoliosis surgery. None of the deformity related parameters in the multiple regressions were significant. However, the twenty patients with the smallest Cobb angles after surgery reported significantly higher SRS scores than the twenty patients with the largest Cobb angles after surgery, but there was no difference on the basis of rib hump correction. Discussion. Patients undergoing thoracoscopic (keyhole) anterior scoliosis correction report good SRS scores which are comparable to those in previous studies. We suggest that the absence of any statistically significant difference in SRS scores between patients with and without rod or screw complications is because these complications are not associated with any clinically significant loss of correction in our patient group. The Cobb angle after surgery was the only significant predictor of patient satisfaction when comparing subgroups of patients with the largest and smallest Cobb angles after surgery.