130 resultados para PI compensator


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses the effects of thyristor controlled series compensator (TCSC), a series FACTS controller, on the transient stability of a power system. Trajectory sensitivity analysis (TSA) has been used to measure the transient stability condition of the system. The TCSC is modeled by a variable capacitor, the value of which changes with the firing angle. It is shown that TSA can be used in the design of the controller. The optimal locations of the TCSC-controller for different fault conditions can also be identified with the help of TSA. The paper depicts the advantage of the use of TCSC with a suitable controller over fixed capacitor operation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simulation study of a custom power park (CPP) is presented. It is assumed that the park contains unbalanced and nonlinear loads in addition to a sensitive load. Two different types of compensators are used separately to protect the sensitive load against unbalance and distortion caused by the other loads. It has been shown that a shunt compensator can regulate the voltage of the CPP bus, whereas the series compensator can only regulate the sensitive load terminal voltage. Additional issues such as the load transfer through a static transfer switch, detection of sag/fault etc. are also discussed. The concepts are validated through PSCAD/EMTDC simulation studies on a sample distribution system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flying capacitor multilevel inverter (FCMLI) is a multiple voltage level inverter topology intended for high-power and high-voltage operations at low distortion. It uses capacitors, called flying capacitors, to clamp the voltage across the power semiconductor devices. A method for controlling the FCMLI is proposed which ensures that the flying capacitor voltages remain nearly constant using the preferential charging and discharging of these capacitors. A static synchronous compensator (STATCOM) and a static synchronous series compensator (SSSC) based on five-level flying capacitor inverters are proposed. Control schemes for both the FACTS controllers are developed and verified in terms of voltage control, power flow control, and power oscillation damping when installed in a single-machine infinite bus (SMIB) system. Simulation studies are performed using PSCAD/EMTDC to validate the efficacy of the control scheme and the FCMLI-based flexible alternating current transmission system (FACTS) controllers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, the commonly used switching schemes for sliding mode control of power converters is analyzed and designed in the frequency domain. Particular application of a distribution static compensator (DSTATCOM) in voltage control mode is investigated in a power distribution system. Tsypkin's method and describing function is used to obtain the switching conditions for the two-level and three-level voltage source inverters. Magnitude conditions of carrier signals are developed for robust switching of the inverter under carrier-based modulation scheme of sliding mode control. The existence of border collision bifurcation is identified to avoid the complex switching states of the inverter. The load bus voltage of an unbalanced three-phase nonstiff radial distribution system is controlled using the proposed carrier-based design. The results are validated using PSCAD/EMTDC simulation studies and through a scaled laboratory model of DSTATCOM that is developed for experimental verification

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents the stability analysis for a distribution static compensator (DSTATCOM) that operates in current control mode based on bifurcation theory. Bifurcations delimit the operating zones of nonlinear circuits and, hence, the capability to compute these bifurcations is of important interest for practical design. A control design for the DSTATCOM is proposed. Along with this control, a suitable mathematical representation of the DSTATCOM is proposed to carry out the bifurcation analysis efficiently. The stability regions in the Thevenin equivalent plane are computed for different power factors at the point of common coupling. In addition, the stability regions in the control gain space, as well as the contour lines for different Floquet multipliers are computed. It is demonstrated through bifurcation analysis that the loss of stability in the DSTATCOM is due to the emergence of a Neimark bifurcation. The observations are verified through simulation studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a case study of a design for a complete microair vehicle thruster. Fixed-pitch small-scale rotors, brushless motors, lithium-polymer cells, and embedded control are combined to produce a mechanically simple, high-performance thruster with potentially high reliability. The custom rotor design requires a balance between manufacturing simplicity and rigidity of a blade versus its aerodynamic performance. An iterative steady-state aeroelastic simulator is used for holistic blade design. The aerodynamic load disturbances of the rotor-motor system in normal conditions are experimentally characterized. The motors require fast dynamic response for authoritative vehicle flight control. We detail a dynamic compensator that achieves satisfactory closed-loop response time. The experimental rotor-motor plant displayed satisfactory thrust performance and dynamic response.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the increase in the level of global warming, renewable energy based distributed generators (DGs) will increasingly play a dominant role in electricity production. Distributed generation based on solar energy (photovoltaic and solar thermal), wind, biomass, mini-hydro along with use of fuel cells and micro turbines will gain considerable momentum in the near future. A microgrid consists of clusters of load and distributed generators that operate as a single controllable system. The interconnection of the DG to the utility/grid through power electronic converters has raised concern about safe operation and protection of the equipments. Many innovative control techniques have been used for enhancing the stability of microgrid as for proper load sharing. The most common method is the use of droop characteristics for decentralized load sharing. Parallel converters have been controlled to deliver desired real power (and reactive power) to the system. Local signals are used as feedback to control converters, since in a real system, the distance between the converters may make the inter-communication impractical. The real and reactive power sharing can be achieved by controlling two independent quantities, frequency and fundamental voltage magnitude. In this thesis, an angle droop controller is proposed to share power amongst converter interfaced DGs in a microgrid. As the angle of the output voltage can be changed instantaneously in a voltage source converter (VSC), controlling the angle to control the real power is always beneficial for quick attainment of steady state. Thus in converter based DGs, load sharing can be performed by drooping the converter output voltage magnitude and its angle instead of frequency. The angle control results in much lesser frequency variation compared to that with frequency droop. An enhanced frequency droop controller is proposed for better dynamic response and smooth transition between grid connected and islanded modes of operation. A modular controller structure with modified control loop is proposed for better load sharing between the parallel connected converters in a distributed generation system. Moreover, a method for smooth transition between grid connected and islanded modes is proposed. Power quality enhanced operation of a microgrid in presence of unbalanced and non-linear loads is also addressed in which the DGs act as compensators. The compensator can perform load balancing, harmonic compensation and reactive power control while supplying real power to the grid A frequency and voltage isolation technique between microgrid and utility is proposed by using a back-to-back converter. As utility and microgrid are totally isolated, the voltage or frequency fluctuations in the utility side do not affect the microgrid loads and vice versa. Another advantage of this scheme is that a bidirectional regulated power flow can be achieved by the back-to-back converter structure. For accurate load sharing, the droop gains have to be high, which has the potential of making the system unstable. Therefore the choice of droop gains is often a tradeoff between power sharing and stability. To improve this situation, a supplementary droop controller is proposed. A small signal model of the system is developed, based on which the parameters of the supplementary controller are designed. Two methods are proposed for load sharing in an autonomous microgrid in rural network with high R/X ratio lines. The first method proposes power sharing without any communication between the DGs. The feedback quantities and the gain matrixes are transformed with a transformation matrix based on the line R/X ratio. The second method involves minimal communication among the DGs. The converter output voltage angle reference is modified based on the active and reactive power flow in the line connected at point of common coupling (PCC). It is shown that a more economical and proper power sharing solution is possible with the web based communication of the power flow quantities. All the proposed methods are verified through PSCAD simulations. The converters are modeled with IGBT switches and anti parallel diodes with associated snubber circuits. All the rotating machines are modeled in detail including their dynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A polycaprolactone (PCL)–collagen electrospun mesh is proposed as a novel alternative to the conventional periosteal graft in autologous chondrocyte implantation. This is the first known attempt in designing a cartilage resurfacing membrane using a mechanically resilient PCL mesh with a weight-average molecular weight of 139 300 that is enhanced with bioactive collagen. PCL–collagen 10, 20 and 40% electrospun meshes (Coll-10, Coll-20 and Coll-40) were evaluated and it was discovered that the retention of surface collagen could only be achieved in Coll-20 and Coll-40. Furthermore Coll-20 was stiffer and stronger than Coll-40 and it satisfied the mechanical demands at the cartilage implant site. When seeded with mesenchymal stem cells (MSCs), the cells adhered on the surface of the Coll-20 mesh and they remained viable over a period of 28 days; however, they were unable to infiltrate through the dense meshwork. Cell compatibility was also noted in the chondrogenic environment as the MSCs differentiated into chondrocytes with the expression of Sox9, aggrecan and collagen II. More importantly, the mesh did not induce a hypertrophic response from the cells. The current findings support the use of Coll-20 as a cartilage patch, and future implantation studies are anticipated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Paesaggio ed infrastrutture viarie sono un binomio molto forte: il primo ha insito il concetto di accessibilità, in quanto non può esistere senza la presenza di un osservatore; la strada, invece, trova i fattori che la connotano nel suo rapporto con la morfologia su cui insiste. Le infrastrutture viarie sono elemento strutturale e strutturante non solo di un territorio, ma anche di un paesaggio. Le attuali esigenze di mobilità portano oggi a ripensare ed adeguare molte infrastrutture viarie: laddove è possibile si potenziano le strutture esistenti, in diversi casi si ricorre a nuovi tracciati o a varianti di percorso. Porsi il problema di conservare itinerari testimoni della cultura materiale ed economica di una società implica considerazioni articolate, che travalicano i limiti del sedime: una via è un organismo più complesso della semplice linea di trasporto in quanto implica tutta una serie di manufatti a supporto della mobilità e soprattutto il corridoio infrastrutturale che genera e caratterizza, ovvero una porzione variabile di territorio definita sia dal tracciato che dalla morfologia del contesto. L’evoluzione dei modelli produttivi ed economici, che oggi porta quote sempre maggiori di popolazione a passare un tempo sempre minore all’interno del proprio alloggio, rende la riflessione sulle infrastrutture viarie dismesse o declassate occasione per la progettazione di spazi per l’abitare collettivo inseriti in contesti paesaggistici, tanto urbani che rurali, tramite reti di percorsi pensate per assorbire tagli di mobilità specifici e peculiari. Partendo da queste riflessioni la Tesi si articola in: Individuazioni del contesto teorico e pratico: Lo studio mette in evidenza come la questione delle infrastrutture viarie e del loro rapporto con il paesaggio implichi riflessioni incrociate a diversi livelli e tramite diverse discipline. La definizione dello spazio fisico della strada passa infatti per la costruzione di un itinerario, un viaggio che si appoggia tanto ad elementi fisici quanto simbolici. La via è un organismo complesso che travalica il proprio sedime per coinvolgere una porzione ampia di territorio, un corridoio variabile ed articolato in funzione del paesaggio attraversato. Lo studio propone diverse chiavi di lettura, mettendo in luce le possibili declinazioni del tema, in funzione del taglio modale, del rapporto con il contesto, del regime giuridico, delle implicazioni urbanistiche e sociali. La mobilità dolce viene individuata quale possibile modalità di riuso, tutela e recupero, del patrimonio diffuso costituito dalle diversi reti di viabilità. Antologia di casi studio: Il corpo principale dello studio si basa sulla raccolta, analisi e studio dello stato dell’arte nel settore; gli esempi raccolti sono presentati in due sezioni: la prima dedicata alle esperienze più significative ed articolate, che affrontano il recupero delle infrastrutture viarie a più livelli ed in modo avanzato non concentrandosi solo sulla conversione del sedime, ma proponendo un progetto che coinvolga tutto il corridoio attraversato dall’infrastruttura; la seconda parte illustra la pratica corrente nelle diverse realtà nazionali, ponendo in evidenza similitudini e differenze tra i vari approcci.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il Consiglio di Amministrazione (CdA) è il principale organo di governo delle aziende. La letteratura gli attribuisce tre ruoli: controllo, indirizzo strategico e collegamento con l’ambiente (networking). Precedenti studi empirici hanno analizzato se un Consiglio di Amministrazione è attivo o meno in tutti e tre i ruoli in un dato momento. Nel presente lavoro, invece, si propone un approccio «contingente» e si analizzano i ruoli svolti dal CdA al variare delle condizioni interne (aziende in crisi o di successo) ed esterne (aziende in settori competitivi o regolamentati).. L’indagine empirica è stata condotta su un campione di 301 imprese italiane di grandi dimensioni. I risultati supportano la tesi iniziale secondo cui le condizioni interne ed esterne incidono sul ruolo svolto dal CdA. In particolare i risultati evidenziano che il CdA non svolge sempre tutti e tre i ruoli nello stesso momento, ma esso si concentra sul ruolo o sui ruoli che assumono grande importanza nella situazione in cui si trova l’azienda. Con riferimento alle condizioni interne, nelle imprese in crisi il CdA è attivo in tutti e tre i ruoli, mentre in quelle di successo prevale un orientamento verso la funzione strategica. Nelle aziende che operano in settori competitivi il ruolo di controllo è più pressante mentre nei settori regolamentati prevale una funzione di networking.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Melt electrospinning is one aspect of electrospinning with relatively little published literature, although the technique avoids solvent accumulation and/or toxicity which is favoured in certain applications. In the study reported, we melt-electrospun blends of poly(ε-caprolactone) (PCL) and an amphiphilic diblock copolymer consisting of poly(ethylene glycol) and PCL segments (PEG-block-PCL). A custom-made electrospinning apparatus was built and various combinations of instrument parameters such as voltage and polymer feeding rate were investigated. Pure PEG-block-PCL copolymer melt electrospinning did not result in consistent and uniform fibres due to the low molecular weight, while blends of PCL and PEG-block-PCL, for some parameter combinations and certain weight ratios of the two components, were able to produce continuous fibres significantly thinner (average diameter of ca 2 µm) compared to pure PCL. The PCL fibres obtained had average diameters ranging from 6 to 33 µm and meshes were uniform for the lowest voltage employed while mesh uniformity decreased when the voltage was increased. This approach shows that PCL and blends of PEG-block-PCL and PCL can be readily processed by melt electrospinning to obtain fibrous meshes with varied average diameters and morphologies that are of interest for tissue engineering purposes. Copyright © 2010 Society of Chemical Industry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The idealised theory for the quasi-static flow of granular materials which satisfy the Coulomb-Mohr hypothesis is considered. This theory arises in the limit that the angle of internal friction approaches $\pi/2$, and accordingly these materials may be referred to as being `highly frictional'. In this limit, the stress field for both two-dimensional and axially symmetric flows may be formulated in terms of a single nonlinear second order partial differential equation for the stress angle. To obtain an accompanying velocity field, a flow rule must be employed. Assuming the non-dilatant double-shearing flow rule, a further partial differential equation may be derived in each case, this time for the streamfunction. Using Lie symmetry methods, a complete set of group-invariant solutions is derived for both systems, and through this process new exact solutions are constructed. Only a limited number of exact solutions for gravity driven granular flows are known, so these results are potentially important in many practical applications. The problem of mass flow through a two-dimensional wedge hopper is examined as an illustration.