153 resultados para Collagen V
Resumo:
The CDKN2 gene, encoding the cyclin dependent kinase inhibitor p16, is a tumour suppressor gene involved in melanoma and maps to chromosome band 9p22. Mutations or interstitial deletions of this gene have been found both in the germline of familial melanoma cases and somatically in melanoma cell lines. Previous mutation analyses of melanoma cell lines have indicated a high frequency of C:G to T:A transitions, with all of these mutations occurring at dipyrimidine sites. Including three melanoma cell lines carrying tandem CC to TT mutations, the spectrum of mutations so far reported indicates a possible role for u.v. radiation in the mutagenesis of this gene in some tumours. To further examine this hypothesis we have characterised mutations of the CDKN2 gene in 30 melanoma cell lines. Nineteen lines carried complete or partial homozygous deletions of the gene. Of the remaining cell lines, eight were shown by direct sequencing of PCR products from exon 1 and exon 2 to carry a total of nine different mutations of CDKN2. Two cell lines carried tandem CC to TT mutations and a high rate of C:G to T:A transitions was observed. This study provides further evidence for the role of u.v. light in the genesis of melanoma, with one target being the CDKN2 tumour suppressor gene.
Resumo:
The United States Supreme Court has handed down a once in a generation patent law decision that will have important ramifications for the patentability of non-physical methods, both internationally and in Australia. In Bilski v Kappos, the Supreme Court considered whether an invention must either be tied to a machine or apparatus, or transform an article into a different state or thing to be patentable. It also considered for the first time whether business methods are patentable subject matter. The decision will be of particular interest to practitioners who followed the litigation in Grant v Commissioner of Patents, a Federal Court decision in which a Brisbane-based inventor was denied a patent over a method of protecting an asset from the claims of creditors.
Resumo:
This chapter provides an analysis of feedback from key stakeholders, collected as part of a research project, on the problems and tensions evident in the collective work practices of learning advisers employed in learning assistance services at an Australian metropolitan university (Peach, 2003). The term 'learning assistance' is used in the Australian higher education sector generally to refer to student support services that include assistance with academic writing and other study skills. The aim of the study was to help learning advisers and other key stakeholders develop a better understanding of the work activity with a view to using this understanding to generate improvements in service provision. Over twenty problems and associated tensions were identified through stakeholder feedback however the focus of this chapter is the analysis of tensions related to a cluster of problems referred to as cost-efficiency versus quality service. Theoretical modelling derived from the tools made available through cultural historical activity theory and expansive visibilsation (Engestrom and Miettinen, 1999) and excerpts from data are used to illustrate how different understandings of the purpose of learning assistance services impacts on the work practices of learning advisers and creates problems and tensions in relation to the type of service available (including use of technology),level of service available, and learning adviser workload.
Resumo:
In Central Queensland Mining Supplies Pty Ltd v Columbia Steel Casting Co Ltd [2011] QSC 183 Applegarth J considered complaints made by the defendant about the approach the plaintiff had taken in its endeavour to comply with its disclosure obligation under r 211 of the Uniform Civil Procedure Rules 1999 (Qld). The judgment also provides an indication of the direction the court is taking in relation to disclosure and document management in matters involving large numbers of documents.
Resumo:
This work is a theoretical investigation into the coupling of a single excited quantum emitter to the plasmon mode of a V groove waveguide. The V groove waveguide consists of a triangular channel milled in gold and the emitter is modeled as a dipole emitter, and could represent a quantum dot, nitrogen vacancy in diamond, or similar. In this work the dependence of coupling efficiency of emitter to plasmon mode is determined for various geometrical parameters of the emitter-waveguide system. Using the finite element method, the effect on coupling efficiency of the emitter position and orientation, groove angle, groove depth, and tip radius, is studied in detail. We demonstrate that all parameters, with the exception of groove depth, have a significant impact on the attainable coupling efficiency. Understanding the effect of various geometrical parameters on the coupling between emitters and the plasmonic mode of the waveguide is essential for the design and optimization of quantum dot–V groove devices.
Resumo:
Over the last few decades, electric and electromagnetic fields have achieved important role as stimulator and therapeutic facility in biology and medicine. In particular, low magnitude, low frequency, pulsed electromagnetic field has shown significant positive effect on bone fracture healing and some bone diseases treatment. Nevertheless, to date, little attention has been paid to investigate the possible effect of high frequency, high magnitude pulsed electromagnetic field (pulse power) on functional behaviour and biomechanical properties of bone tissue. Bone is a dynamic, complex organ, which is made of bone materials (consisting of organic components, inorganic mineral and water) known as extracellular matrix, and bone cells (live part). The cells give the bone the capability of self-repairing by adapting itself to its mechanical environment. The specific bone material composite comprising of collagen matrix reinforced with mineral apatite provides the bone with particular biomechanical properties in an anisotropic, inhomogeneous structure. This project hypothesized to investigate the possible effect of pulse power signals on cortical bone characteristics through evaluating the fundamental mechanical properties of bone material. A positive buck-boost converter was applied to generate adjustable high voltage, high frequency pulses up to 500 V and 10 kHz. Bone shows distinctive characteristics in different loading mode. Thus, functional behaviour of bone in response to pulse power excitation were elucidated by using three different conventional mechanical tests applying three-point bending load in elastic region, tensile and compressive loading until failure. Flexural stiffness, tensile and compressive strength, hysteresis and total fracture energy were determined as measure of main bone characteristics. To assess bone structure variation due to pulse power excitation in deeper aspect, a supplementary fractographic study was also conducted using scanning electron micrograph from tensile fracture surfaces. Furthermore, a non-destructive ultrasonic technique was applied for determination and comparison of bone elasticity before and after pulse power stimulation. This method provided the ability to evaluate the stiffness of millimetre-sized bone samples in three orthogonal directions. According to the results of non-destructive bending test, the flexural elasticity of cortical bone samples appeared to remain unchanged due to pulse power excitation. Similar results were observed in the bone stiffness for all three orthogonal directions obtained from ultrasonic technique and in the bone stiffness from the compression test. From tensile tests, no significant changes were found in tensile strength and total strain energy absorption of the bone samples exposed to pulse power compared with those of the control samples. Also, the apparent microstructure of the fracture surfaces of PP-exposed samples (including porosity and microcracks diffusion) showed no significant variation due to pulse power stimulation. Nevertheless, the compressive strength and toughness of millimetre-sized samples appeared to increase when the samples were exposed to 66 hours high power pulsed electromagnetic field through screws with small contact cross-section (increasing the pulsed electric field intensity) compare to the control samples. This can show the different load-bearing characteristics of cortical bone tissue in response to pulse power excitation and effectiveness of this type of stimulation on smaller-sized samples. These overall results may address that although, the pulse power stimulation can influence the arrangement or the quality of the collagen network causing the bone strength and toughness augmentation, it apparently did not affect the mineral phase of the cortical bone material. The results also confirmed that the indirect application of high power pulsed electromagnetic field at 500 V and 10 kHz through capacitive coupling method, was athermal and did not damage the bone tissue construction.