126 resultados para End-Winding


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: High-flow nasal cannulae (HFNC) create positive oropharyngeal airway pressure but it is unclear how their use affects lung volume. Electrical impedance tomography (EIT) allows assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (Paw) and end-expiratory lung volume (EELV), and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate (RR), dyspnoea, tidal volume and oxygenation; and the interaction between body mass index (BMI) and EELV. Methods: Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, Paw, PaO2/FiO2 ratio, RR and modified Borg scores were recorded first on low flow oxygen (nasal cannula or Hudson face mask) and then on HFNC. Results: A strong and significant correlation existed between Paw and end-expiratory lung impedance (EELI) (r=0.7, p<0.001). Compared with low flow oxygen, HFNC significantly increased EELI by 25.6% (95% CI 24.3, 26.9) and Paw by 3.0 cmH2O (95% CI 2.4, 3.7). RR reduced by 3.4 breaths per minute (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3) and PaO2/FiO2 ratio improved by 30.6 mmHg (95% CI 17.9, 43.3). HFNC improved subjective dyspnoea scoring (p=0.023). Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (p<0.001). Conclusions: This study suggests that HFNC improve dyspnoea and oxygenation by increasing both EELV and tidal volume, and are most beneficial in patients with higher BMIs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines discussions of Generation Y within higher education discourse, arguing the sector’s use of the term to describe students is misguided for three reasons. First, portraying students as belonging to Generation Y homogenises people undertaking higher education as young, middle-class and technologically literate. Second, speaking of Generation Y students allows constructivism to be reinvented as a ‘new’ learning and teaching philosophy. Third, the Generation Y university student has become a central figure in concerns about technology’s role in learning and teaching. While the notion of the ‘Generation Y student’ creates the illusion that higher education institutions understand their constituents, ultimately, it is of little value in explaining young adults’ educational experiences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective quantification of three-dimensional kinematics during different functional and occupational tasks is now more in demand than ever. The introduction of new generation of low-cost passive motion capture systems from a number of manufacturers has made this technology accessible for teaching, clinical practice and in small/medium industry. Despite the attractive nature of these systems, their accuracy remains unproved in independent tests. We assessed static linear accuracy, dynamic linear accuracy and compared gait kinematics from a Vicon MX20 system to a Natural Point OptiTrack system. In all experiments data were sampled simultaneously. We identified both systems perform excellently in linear accuracy tests with absolute errors not exceeding 1%. In gait data there was again strong agreement between the two systems in sagittal and coronal plane kinematics. Transverse plane kinematics differed by up to 3 at the knee and hip, which we attributed to the impact of soft tissue artifact accelerations on the data. We suggest that low-cost systems are comparably accurate to their high-end competitors and offer a platform with accuracy acceptable in research for laboratories with a limited budget.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1999 Richards compared the accuracy of commercially available motion capture systems commonly used in biomechanics. Richards identified that in static tests the optical motion capture systems generally produced RMS errors of less than 1.0 mm. During dynamic tests, the RMS error increased to up to 4.2 mm in some systems. In the last 12 years motion capture systems have continued to evolve and now include high-resolution CCD or CMOS image sensors, wireless communication, and high full frame sampling frequencies. In addition to hardware advances, there have also been a number of advances in software, which includes improved calibration and tracking algorithms, real time data streaming, and the introduction of the c3d standard. These advances have allowed the system manufactures to maintain a high retail price in the name of advancement. In areas such as gait analysis and ergonomics many of the advanced features such as high resolution image sensors and high sampling frequencies are not required due to the nature of the task often investigated. Recently Natural Point introduced low cost cameras, which on face value appear to be suitable as at very least a high quality teaching tool in biomechanics and possibly even a research tool when coupled with the correct calibration and tracking software. The aim of the study was therefore to compare both the linear accuracy and quality of angular kinematics from a typical high end motion capture system and a low cost system during a simple task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Findings from a Queensland coronial inquest highlight the complex clinical, ethical and legal issues that arise in end-of-life care when clinicians and family members disagree about a diagnosis of clinical futility. The tension between the law and best medical practice is highlighted in this case, as doctors are compelled to seek family consent to not commence a futile intervention. Good communication between doctors and families, as well as community and professional education, is essential to resolve tensions that can arise when there is disagreement about treatment at the end of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article explores an important temporal aspect of the design of strategic alliances by focusing on the issue of time bounds specification. Time bounds specification refers to a choice on behalf of prospective alliance partners at the time of alliance formation to either pre-specify the duration of an alliance to a specific time window, or to keep the alliance open-ended (Reuer & Ariňo, 2007). For instance, Das (2006) mentions the example of the alliance between Telemundo Network and Mexican Argos Comunicacion (MAC). Announced in October 2000, this alliance entailed a joint production of 1200 hours of comedy, news, drama, reality and novella programs (Das, 2006). Conditioned on the projected date of completing the 1200 hours of programs, Telemundo Network and MAC pre-specified the time bounds of the alliance ex ante. Such time-bound alliances are said to be particularly prevalent in project-based industries, like movie production, construction, telecommunications and pharmaceuticals (Schwab & Miner, 2008). In many other instances, however, firms may choose to keep their alliances open-ended, not specifying a specific time bound at the time of alliance formation. The choice between designing open-ended alliances that are “built to last”, versus time bound alliances that are “meant to end” is important. Seminal works like Axelrod (1984), Heide & Miner (1992), and Parkhe (1993) demonstrated that the choice to place temporal bounds on a collaborative venture has important implications. More specifically, collaborations that have explicit, short term time bounds (i.e. what is termed a shorter “shadow of the future”) are more likely to experience opportunism (Axelrod, 1984), are more likely to focus on the immediate present (Bakker, Boros, Kenis & Oerlemans, 2012), and are less likely to develop trust (Parkhe, 1993) than alliances for which time bounds are kept indeterminate. These factors, in turn, have been shown to have important implications for the performance of alliances (e.g. Kale, Singh & Perlmutter, 2000). Thus, there seems to be a strong incentive for organizations to form open-ended strategic alliances. And yet, Reuer & Ariňo (2007), one of few empirical studies that details the prevalence of time-bound and open-ended strategic alliances, found that about half (47%) of the alliances in their sample were time bound, the other half were open-ended. What conditions, then, determine this choice?

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Charitable organisations have remained exempt from income tax in Australia since the first comprehensive state income tax legislation in 18841 through to the current Income Tax Assessment Act 1977. The charitable exemption was also part of the English income tax legislation from its inception in 1799. The Federal Treasurer has released exposure draft legislation which seeks to remove taxation exemptions from some tax exempt organisations that perform any of their activities outside Australia or make trust distributions overseas. The proposed legislation is in response to alleged tax avoidance arrangements which involve tax exempt organisations and charitable trusts. The paper begins by describing the current charity tax exemption provisions under the Income Tax Assessment Act (ITAA). It then turns to tracing the background policy history of the amendments which appear to be at odds with the form and intent of the proposed provisions. The proposed amendments and their practical consequences are then closely scrutinised and found wanting in a number of respects. Alternative strategies are suggested to arrive at an equitable solution to the avoidance mischief.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

What do physicians think of law? Do they know the law? What role does it have in the provision of end-of-life care? Physicians in New South Wales, Victoria and Queensland are being asked about these issues in a study by the Queensland University of Technology entitled ‘Withholding and withdrawing life-sustaining treatment from adults who lack capacity: The role of law in medical practice’. This research aims to examine the role that law plays in decisions to withhold or withdraw life-sustaining treatment from adults who lack capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis C virus (HCV ) core (C) protein is thought to bind to viral RNA before it undergoes oligomerization leading to RNA encapsidation. Details of these events are so far unknown. The 5ʹ-terminal C protein coding sequence that includes an adenine (A)-rich tract is a part of an internal ribosome entry site(IRES). This nucleotide sequence but not the corresponding protein sequence is needed for proper initiation of translation of viral RNA by an IRES-dependent mechanism. In this study, we examined the importance of this sequence for the ability of the C protein to bind to viral RNA. Serially truncated C proteins with deletions from 10 up to 45 N-terminal amino acids were expressed in Escherichia coli, purified and tested for binding to viral RNA by a gel shift assay. The results showed that truncation of the C protein from its N-terminus by more than 10 amino acids abolished almost completely its expression in E. coli. The latter could be restored by adding a tag to the N-terminus of the protein. The tagged proteins truncated by 15 or more amino acids showed an anomalous migration in SDS-PAGE. Truncation by more than 20 amino acids resulted in a complete loss of ability of tagged C protein to bind to viral RNA. These results provide clues to the early events in the C protein - RNA interactions leading to C protein oligomerization, RNA encapsidation and virion assembly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Subjects with atrial fibrillation are at risk of thromboembolic events. The vitamin K antagonists (e.g., warfarin) are useful at preventing coagulation in atrial fibrillation, but are difficult to use. One of the FXa inhibitors, oral apixaban, has been tested as an anticoagulant in atrial fibrillation. Areas covered: In ARISTOTLE (Apixaban for reduction in stroke and other thromboembolic events in atrial fibrillation) apixaban was compared to warfarin in subjects with atrial fibrillation, and shown to cause a lower rate of stroke or systemic embolism and of major bleeding, than warfarin. In the AVERROES (Apixaban versus acetylsalicylic acid [ASA] to prevent stroke in atrial fibrillations patients who have failed or are unsuitable for vitamin K antagonist treatment) trial, stroke or systemic embolism occurred less often with apixaban than aspirin, whereas the occurrence of major bleeding was similar in the groups. Expert opinion: Apixaban is much easier for subjects with atrial fibrillation to use than warfarin, as it does not require regular monitoring by a health professional, with dosage adjustment. In addition to replacing warfarin in subjects with atrial fibrillation who are unable or not prepared to use warfarin, apixaban has the potential to replace warfarin more widely in the prevention of thromboembolism in subjects with atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This small exploratory study sought to understand how people with End Stage Kidney Disease (ESKD) experience the information environment and what information practices they employ in order to inform the decisions they make in relation to treatment and care. Using a constructivist methodology, in-depth interviews were conducted with five people who were receiving haemodialysis in two small satellite dialysis units located in regional and rural communities in New South Wales, Australia. Thematic analysis revealed two types of patients. The first type appears to adopt a received view of information, who do not question their condition; and passively accept information. In the other type, patients were found to be engaged; they actively identified their information needs and quickly learned what that they needed to ask and who to ask. Knowing the information practices of people with ESKD is useful for nephrology nurses when providing patient education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The prevalence of end-stage kidney disease (ESKD) patients is increasing in Vietnam; however, the impact of ESKD and its treatment on a person’s quality of life (QOL) is not well understood. Objective: This research sought to examine the association between monthly income, comorbidity, length of time on dialysis, social support and health-related quality of life (HRQOL) among Vietnamese ESKD patients. Method: Using a descriptive design, 95 patients who were receiving haemodialysis (HD) and peritoneal dialysis (PD) from one hospital in Hanoi, were conveniently sampled. Results: ESKD patients reported having a moderate level of HRQOL. Factors associated with QOL were social support (r= .268, p<.05), comorbid health conditions (r= –.185, p<.05), and length of time on dialysis (r= .182, p<.05). However, monthly income was not significantly related to HRQOL (p>.05). Conclusion: The results seem to indicate that ESKD patients in Vietnam have a high level of support from family members, friends and significant others. There was also a negative impact of comorbid conditions on the QOL of these patients. Based on the results of this study, nurses ought to develop nursing interventions which will lead to a better QOL for patients, and further research into the QOL for ESKD patients in Vietnam is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Endotracheal suctioning causes significant lung derecruitment. Closed suction (CS) minimizes lung volume loss during suction, and therefore, volumes are presumed to recover more quickly postsuctioning. Conflicting evidence exists regarding this. We examined the effects of open suction (OS) and CS on lung volume loss during suctioning, and recovery of end-expiratory lung volume (EELV) up to 30 minutes postsuction. Material and Methods Randomized crossover study examining 20 patients postcardiac surgery. CS and OS were performed in random order, 30 minutes apart. Lung impedance was measured during suction, and end-expiratory lung impedance was measured at baseline and postsuctioning using electrical impedance tomography. Oximetry, partial pressure of oxygen in the alveoli/fraction of inspired oxygen ratio and compliance were collected. Results Reductions in lung impedance during suctioning were less for CS than for OS (mean difference, − 905 impedance units; 95% confidence interval [CI], − 1234 to –587; P < .001). However, at all points postsuctioning, EELV recovered more slowly after CS than after OS. There were no statistically significant differences in the other respiratory parameters. Conclusions Closed suctioning minimized lung volume loss during suctioning but, counterintuitively, resulted in slower recovery of EELV postsuction compared with OS. Therefore, the use of CS cannot be assumed to be protective of lung volumes postsuctioning. Consideration should be given to restoring EELV after either suction method via a recruitment maneuver.