496 resultados para multiple measurements
Resumo:
1.Marine ecosystems provide critically important goods and services to society, and hence their accelerated degradation underpins an urgent need to take rapid, ambitious and informed decisions regarding their conservation and management. 2.The capacity, however, to generate the detailed field data required to inform conservation planning at appropriate scales is limited by time and resource consuming methods for collecting and analysing field data at the large scales required. 3.The ‘Catlin Seaview Survey’, described here, introduces a novel framework for large-scale monitoring of coral reefs using high-definition underwater imagery collected using customized underwater vehicles in combination with computer vision and machine learning. This enables quantitative and geo-referenced outputs of coral reef features such as habitat types, benthic composition, and structural complexity (rugosity) to be generated across multiple kilometre-scale transects with a spatial resolution ranging from 2 to 6 m2. 4.The novel application of technology described here has enormous potential to contribute to our understanding of coral reefs and associated impacts by underpinning management decisions with kilometre-scale measurements of reef health. 5.Imagery datasets from an initial survey of 500 km of seascape are freely available through an online tool called the Catlin Global Reef Record. Outputs from the image analysis using the technologies described here will be updated on the online repository as work progresses on each dataset. 6.Case studies illustrate the utility of outputs as well as their potential to link to information from remote sensing. The potential implications of the innovative technologies on marine resource management and conservation are also discussed, along with the accuracy and efficiency of the methodologies deployed.
Resumo:
Improved glycemic control is the only treatment that has been shown to be effective for diabetic peripheral neuropathy in patients with type 1 diabetes (1). Continuous subcutaneous insulin infusion (CSII) is superior to multiple daily insulin injection (MDI) for reducing HbA1c and hypoglycemic events (2). Here, we have compared the benefits of CSII compared withMDI for neuropathy over 24months....
Resumo:
To enhance the efficiency of regression parameter estimation by modeling the correlation structure of correlated binary error terms in quantile regression with repeated measurements, we propose a Gaussian pseudolikelihood approach for estimating correlation parameters and selecting the most appropriate working correlation matrix simultaneously. The induced smoothing method is applied to estimate the covariance of the regression parameter estimates, which can bypass density estimation of the errors. Extensive numerical studies indicate that the proposed method performs well in selecting an accurate correlation structure and improving regression parameter estimation efficiency. The proposed method is further illustrated by analyzing a dental dataset.
Resumo:
Dysphagia, often associated with conditions such as stroke, Parkinson’s disease, multiple sclerosis, and dementia, causes patients to have difficulty with swallowing food and/or liquids. These patients require their fluids to be thickened using gum-based thickening powders in order to facilitate safe swallowing. These thickened fluids are also used as a vehicle for delivery of crushed medicines. Our in vitro measurements suggest that thickened fluids can delay and reduce the dissolution of a number of medications. This study was conducted to assess the impact of the use of thickened fluids on the clinical pharmacokinetics of oral paracetamol. METHODS 20 Healthy volunteers were administered a single oral dose (1g) of paracetamol as either whole tablets, crushed with water, crushed with semi-solid jam, or crushed with thickened fluid according to a randomised, crossover design. Saliva samples were collected periodically over 8 hr and paracetamol concentration analysed by HPLC-UV. Non-compartmental pharmacokinetic analysis was conducted using Winnonlin®. RESULTS The mean peak concentration (Cmax) of paracetamol ranged between 5.62 – 8.00 μg/mL. Comparison between the crushed paracetamol with thickened water (Level 900) and other treatment options (whole, crushed with water, and crushed with jam) showed there was a significant difference in Cmax at 90% CI (p < 0.05). Also, whole tablet had a significant difference in Cmax between crushed with water and crushed with jam. There was no significant difference in AUC irrespective of the treatment. DISCUSSION The use of thickened water resulted in alteration in the absorption kinetics of paracetamol. Given this interaction, co-administration with thickened fluids may have important clinical implications for medications with a narrow therapeutic index.
Resumo:
This thesis reports on a multiple case study of the actions of three Queensland secondary schools in the context of Year 9 NAPLAN numeracy testing, focusing on their administrative practices, curriculum, pedagogy and assessment. It was established that schools have found it both challenging and costly to operate in an environment of educational reform generally, and NAPLAN testing in particular. The lack of a common understanding of numeracy and the substantial demands of implementing the Australian Curriculum have impacted on schools' ability to prepare students appropriately for NAPLAN numeracy tests. It was concluded that there is scope for schools to improve their approaches to NAPLAN numeracy testing in a way that maximises learning as well as test outcomes.
Resumo:
In an estuary, mixing and dispersion are the result of the combination of large scale advection and small scale turbulence which are both complex to estimate. A field study was conducted in a small sub-tropical estuary in which high frequency (50 Hz) turbulent data were recorded continuously for about 48 hours. A triple decomposition technique was introduced to isolate the contributions of tides, resonance and turbulence in the flow field. A striking feature of the data set was the slow fluctuations which exhibited large amplitudes up to 50% the tidal amplitude under neap tide conditions. The triple decomposition technique allowed a characterisation of broader temporal scales of high frequency fluctuation data sampled during a number of full tidal cycles.
Resumo:
This work examined the suitability of the PAGAT gel dosimeter for use in dose distribution measurements around high-density implants. An assessment of the gels reactivity with various metals was performed and no corrosive effects were observed. An artefact reduction technique was also investigated in order to minimise scattering of the laser light in the optical CT scans. The potential for attenuation and backscatter measurements using this gel dosimeter were examined for a temporary tissue expander's internal magnetic port.
Resumo:
This paper explores the concept that individual dancers leave traces in a choreographer’s body of work and similarly, that dancers carry forward residue of embodied choreographies into other working processes. This presentation will be grounded in a study of the multiple iterations of a programme of solo works commissioned in 2008 from choreographers John Jasperse, Jodi Melnick, Liz Roche and Rosemary Butcher and danced by the author. This includes an exploration of the development by John Jasperse of themes from his solo into the pieces PURE (2008) and Truth, Revised Histories, Wishful Thinking and Flat Out Lies (2009); an adaptation of the solo Business of the Bloom by Jodi Melnick in 2008 and a further adaptation of Business of the Bloom by this author in 2012. It will map some of the developments that occurred through a number of further performances over five years of the solo Shared Material on Dying by Liz Roche and the working process of the (uncompleted) solo Episodes of Flight by Rosemary Butcher. The purpose is to reflect back on authorship in dance, an art form in which lineages of influence can often be clearly observed. Normally, once a choreographic work is created and performed, it is archived through video recording, notation and/or reviews. The dancer is no longer called upon to represent the dance piece within the archive and thus her/his lived presence and experiential perspective disappears. The author will draw on the different traces still inhabiting her body as pathways towards understanding how choreographic movement circulates beyond this moment of performance. This will include the interrogation of ownership of choreographic movement, as once it becomes integrated in the body of the dancer, who owns the dance? Furthermore, certain dancers, through their individual physical characteristics and moving identities, can deeply influence the formation of choreographic signatures, a proposition that challenges the sole authorship role of the choreographer in dance production. This paper will be delivered in a presentation format that will bleed into movement demonstrations alongside video footage of the works and auto-ethnographic accounts of dancing experience. A further source of knowledge will be drawn from extracts of interviews with other dancers including Sara Rudner, Rebecca Hilton and Catherine Bennett.
Resumo:
Purpose: To determine the extent to which the accuracy of magnetic resonance imaging (MRI) based virtual 3-dimensional (3D) models of the intact orbit can approach that of the gold standard, computed tomography (CT) based models. The goal was to determine whether MRI is a viable alternative to CT scans in patients with isolated orbital fractures and penetrating eye injuries, pediatric patients, and patients requiring multiple scans in whom radiation exposure is ideally limited. Materials and Methods: Patients who presented with unilateral orbital fractures to the Royal Brisbane and Women’s Hospital from March 2011 to March 2012 were recruited to participate in this cross-sectional study. The primary predictor variable was the imaging technique (MRI vs CT). The outcome measurements were orbital volume (primary outcome) and geometric intraorbital surface deviations (secondary outcome)between the MRI- and CT-based 3D models. Results: Eleven subjects (9 male) were enrolled. The patients’ mean age was 30 years. On average, the MRI models underestimated the orbital volume of the CT models by 0.50 0.19 cm3 . The average intraorbital surface deviation between the MRI and CT models was 0.34 0.32 mm, with 78 2.7% of the surface within a tolerance of 0.5 mm. Conclusions: The volumetric differences of the MRI models are comparable to reported results from CT models. The intraorbital MRI surface deviations are smaller than the accepted tolerance for orbital surgical reconstructions. Therefore, the authors believe that MRI is an accurate radiation-free alternative to CT for the primary imaging and 3D reconstruction of the bony orbit. �
Resumo:
This paper proposes a recommendation system that supports process participants in taking risk-informed decisions, with the goal of reducing risks that may arise during process execution. Risk reduction involves decreasing the likelihood and severity of a process fault from occurring. Given a business process exposed to risks, e.g. a financial process exposed to a risk of reputation loss, we enact this process and whenever a process participant needs to provide input to the process, e.g. by selecting the next task to execute or by filling out a form, we suggest to the participant the action to perform which minimizes the predicted process risk. Risks are predicted by traversing decision trees generated from the logs of past process executions, which consider process data, involved resources, task durations and other information elements like task frequencies. When applied in the context of multiple process instances running concurrently, a second technique is employed that uses integer linear programming to compute the optimal assignment of resources to tasks to be performed, in order to deal with the interplay between risks relative to different instances. The recommendation system has been implemented as a set of components on top of the YAWL BPM system and its effectiveness has been evaluated using a real-life scenario, in collaboration with risk analysts of a large insurance company. The results, based on a simulation of the real-life scenario and its comparison with the event data provided by the company, show that the process instances executed concurrently complete with significantly fewer faults and with lower fault severities, when the recommendations provided by our recommendation system are taken into account.
Resumo:
Welcome to the Evaluation of course matrix. This matrix is designed for highly qualified discipline experts to evaluate their course, major or unit in a systemic manner. The primary purpose of the Evaluation of course matrix is to provide a tool that a group of academic staff at universities can collaboratively review the assessment within a course, major or unit annually. The annual review will result in you being ready for an external curricula review at any point in time. This tool is designed for use in a workshop format with one, two or more academic staff, and will lead to an action plan for implementation. I hope you find this tool useful in your assessment review.
Resumo:
There have been substantial advances in small field dosimetry techniques and technologies, over the last decade, which have dramatically improved the achievable accuracy of small field dose measurements. This educational note aims to help radiation oncology medical physicists to apply some of these advances in clinical practice. The evaluation of a set of small field output factors (total scatter factors) is used to exemplify a detailed measurement and simulation procedure and as a basis for discussing the possible effects of simplifying that procedure. Field output factors were measured with an unshielded diode and a micro-ionisation chamber, at the centre of a set of square fields defined by a micro-multileaf collimator. Nominal field sizes investigated ranged from 6×6 to 98×98 mm2. Diode measurements in fields smaller than 30 mm across were corrected using response factors calculated using Monte Carlo simulations of the full diode geometry and daisy-chained to match micro-chamber measurements at intermediate field sizes. Diode measurements in fields smaller than 15 mm across were repeated twelve times over three separate measurement sessions, to evaluate the to evaluate the reproducibility of the radiation field size and its correspondence with the nominal field size. The five readings that contributed to each measurement on each day varied by up to 0.26%, for the “very small” fields smaller than 15 mm, and 0.18% for the fields larger than 15 mm. The diode response factors calculated for the unshielded diode agreed with previously published results, within 1.6%. The measured dimensions of the very small fields differed by up to 0.3 mm, across the different measurement sessions, contributing an uncertainty of up to 1.2% to the very small field output factors. The overall uncertainties in the field output factors were 1.8% for the very small fields and 1.1% for the fields larger than 15 mm across. Recommended steps for acquiring small field output factor measurements for use in radiotherapy treatment planning system beam configuration data are provided.