353 resultados para Optical testing
Resumo:
Piezoelectric polymers based on polyvinylidene fluoride (PVDF) are of interest as smart materials for novel space-based telescope applications. Dimensional adjustments of adaptive thin polymer films are achieved via controlled charge deposition. Predicting their long-term performance requires a detailed understanding of the piezoelectric property changes that develop during space environmental exposure. The overall materials performance is governed by a combination of chemical and physical degradation processes occurring in low Earth orbit as established by our past laboratory-based materials performance experiments (see report SAND 2005-6846). Molecular changes are primarily induced via radiative damage, and physical damage from temperature and atomic oxygen exposure is evident as depoling, loss of orientation and surface erosion. The current project extension has allowed us to design and fabricate small experimental units to be exposed to low Earth orbit environments as part of the Materials International Space Station Experiments program. The space exposure of these piezoelectric polymers will verify the observed trends and their degradation pathways, and provide feedback on using piezoelectric polymer films in space. This will be the first time that PVDF-based adaptive polymer films will be operated and exposed to combined atomic oxygen, solar UV and temperature variations in an actual space environment. The experiments are designed to be fully autonomous, involving cyclic application of excitation voltages, sensitive film position sensors and remote data logging. This mission will provide critically needed feedback on the long-term performance and degradation of such materials, and ultimately the feasibility of large adaptive and low weight optical systems utilizing these polymers in space.
Resumo:
This is the protocol for a review and there is no abstract. The objectives are as follows: Our objective is to determine if there is sufficient evidence to recommend the use of pH testing (the intervention under scrutiny) for verification of correct placement of nasogastric tubes in adults and children. To this end, we will attempt to answer the following questions: 1. In adults and children, is pH testing an effective and safe method for determining whether nasogastric tubes are correctly positioned in the stomach before feeding (or delivery of any fluid) begins? 2. What evidence is there about the risk of adverse events in the case of incorrect placement? For this review, pH testing is defined as: litmus paper, pH indicator test strips, pH meters. These will be tested against other methods used for detecting placement of nasogastric tubes, including visual examination of aspirate, auscultation with insufflation of air, detection of air bubbles in a bowl of water, X-ray, ultrasonography, endoscopy, enzyme analysis of aspirate, capnography, and other methods that do not rely on measurement of pH.
Resumo:
This paper reports on an Australian study that explored the costs and benefits of the National Assessment Programme, Literacy and Numeracy (NAPLAN) testing, both tangible and intangible, of Year 9 students in three Queensland schools. The study commenced with a review of pertinent studies and other related material about standardised testing in Australia, the USA and UK. Information about NAPLAN testing and reporting, and the pedagogical impacts of standardised testing were identified, however little about administrative costs to schools was found. A social constructivist perspective and a multiple case study approach were used to explore the actions of school managers and teachers in three Brisbane secondary schools. The study found that the costs of NAPLAN testing to schools fell into two categories: preparation of students for the testing; and administration of the tests. Whilst many of the costs could not be quantified, they were substantial and varied according to the education sector in which the school operated. The benefits to schools of NAPLAN testing were found to be limited. The findings have implications for governments, curriculum authorities and schools, leading to the conclusion that, from a school perspective, the benefits of NAPLAN testing do not justify the costs.
Resumo:
This paper considers the legal challenges to the legal validity of the patents held by Myriad Genetics in respect of genetic testing for breast cancer and ovarian cancer. It argues that broad-based patents on gene sequences and medical diagnostics will have a harmful effect upon access to patient care, genetic research, and the administration of public health care.
Resumo:
Graphitic like layered materials exhibit intriguing electronic structures and thus the search for new types of two-dimensional (2D) monolayer materials is of great interest for developing novel nano-devices. By using density functional theory (DFT) method, here we for the first time investigate the structure, stability, electronic and optical properties of monolayer lead iodide (PbI2). The stability of PbI2 monolayer is first confirmed by phonon dispersion calculation. Compared to the calculation using generalized gradient approximation, screened hybrid functional and spin–orbit coupling effects can not only predicts an accurate bandgap (2.63 eV), but also the correct position of valence and conduction band edges. The biaxial strain can tune its bandgap size in a wide range from 1 eV to 3 eV, which can be understood by the strain induced uniformly change of electric field between Pb and I atomic layer. The calculated imaginary part of the dielectric function of 2D graphene/PbI2 van der Waals type hetero-structure shows significant red shift of absorption edge compared to that of a pure monolayer PbI2. Our findings highlight a new interesting 2D material with potential applications in nanoelectronics and optoelectronics.
Resumo:
A highly extended dithienothiophene comonomer building block was used in combination with highly fused aromatic furan substituted diketopyrrolopyrrole for the synthesis of novel donor–acceptor alternating copolymer PDPPF-DTT. Upon testing PDPPF-DTT as a channel semiconductor in top contact bottom gate organic field effect transistors (OFETs), it was found to exhibit p-channel behaviour. The highest hole mobility of 3.56 cm2 V−1 s−1 was reported for PDPPF-DTT. To our knowledge, this is the highest mobility reported so far for the furan flanked diketopyrrolopyrrole class of copolymers using conventional device geometry with straightforward processing.
Resumo:
Hereditary haemochromatosis (HH) is the most common lethal monogenic human disease, affecting roughly 1 in 300 white northern Europeans. Homozygosity for the C282Y polymorphism within the HFE gene causes more than 80% of cases, with compound heterozygosity of the C282Y and H63D polymorphism also increasing susceptibility to disease. The aim of this study was to determine the frequency of the C282Y and H63D polymorphisms in the disease, and to assess the risk of HH in heterozygotes for the C282Y polymorphism. 128 patients were recruited because of either radiographic chondrocalcinosis (at least bicompartmental knee disease or joints other than the knee involved) or CPPD pseudogout. Genotyping of the HFE C282Y and H63D mutations was performed using PCR/SSP and genotypes for the C282Y polymorphism confirmed by PCR/RFLP. Historical white European control data were used for comparison. Two previously undiagnosed C282Y homozygotes (1.6%), and 16 C282Y heterozygotes (12.5%), including four (3.1%) C282Y/ H63D compound heterozygotes were identified. This represents a significant overrepresentation of C282Y homozygotes (relative risk 3.4, p-0.037), but the number of heterozygotes was not significantly increased. At a cost per test of £1 for each subject, screening all patients with chondrocalcinosis using the above ascertainment criteria costs only £64 for each case of haemochromatosis identified, clearly a highly cost effective test given the early mortality associated with untreated haemochromatosis. Routine screening for haemochromatosis in patients with appreciable chondrocatcinosis is recommended.
Resumo:
Recent international educational developments have important implications for the skills and understandings in curriculum and assessment that teachers develop, both in pre-service and in practice. Global developments in curriculum and assessment reform require teachers to utilise a network of knowledges and develop a repertoire of assessment skills and understandings. In a context of testing, accountability and auditing, data analysis skills are increasingly required to examine pedagogic practices for the development of intervention teaching and learning strategies to improve learning outcomes for all students (Marsh, 2009). However, too often the data are used predominantly for accountability purposes that serve at national levels as a catalyst for measurement, comparison and allocation of funding (Lingard and Sellar, 2013). With increased accountability demands brought about by global competitiveness and programs for international measurement of educational attainment, there has also emerged an increase in the use of testing, which in some countries has become the dominant form of assessment. For example in Australia, national testing of students in Years 3, 5, 7 and 9 began in 2008 under the National Australia Program – Literacy and Numeracy (NAPLAN). The results from this program for each school are published on the My School website (www.myschool.edu.au), increasing the competitive nature of the testing and intensifying the demands on teachers and schools. In particular, there has been a shift in the enacted curriculum in Australia to a focus on literacy and numeracy because the curriculum is tested.
Resumo:
Objective National guidelines for management of intermediate risk patients with suspected acute coronary syndrome, in whom AMI has been excluded, advocate provocative testing to final risk stratify these patients into low risk (negative testing) or high risk (positive testing suggestive of unstable angina). Adults less than 40 years have a low pretest probability of acute coronary syndrome. The utility of exercise stress testing in young adults with chest pain suspected of acute coronary syndrome who have National Heart Foundation intermediate risk features was evaluated Methods A retrospective analysis of exercise stress testing performed on patients less than 40 years was evaluated. Patients were enrolled on a chest pain pathway and had negative serial ECGs and cardiac biomarkers before exercise stress testing to rule-out acute coronary syndrome. Chart review was completed on patients with positive stress tests. Results The 3987 patients with suspected intermediate risk acute coronary syndrome underwent exercise stress testing. One thousand and twenty-seven (25.8%) were aged less than 40 years (age 33.3 ± 4.8 years). Four of these 1027 patients had a positive exercise stress test (0.4% incidence of positive exercise stress testing). Of those, three patients had subsequent non-invasive functional testing that yielded a negative result. One patient declined further investigations. Assuming this was a true positive exercise stress test, the incidence of true positive exercise stress testing would have been 0.097% (95% confidence interval: 0.079–0.115%) (one of 1027 patients). Conclusions Routine exercise stress testing has limited value in the risk stratification of adults less than 40 years with suspected intermediate risk of acute coronary syndrome
Resumo:
Spontaneous emission (SE) of a Quantum emitter depends mainly on the transmission strength between the upper and lower energy levels as well as the Local Density of States (LDOS)[1]. When a QD is placed in near a plasmon waveguide, LDOS of the QD is increased due to addition of the non-radiative decay and a plasmonic decay channel to free space emission[2-4]. The slow velocity and dramatic concentration of the electric field of the plasmon can capture majority of the SE into guided plasmon mode (Гpl ). This paper focused on studying the effect of waveguide height on the efficiency of coupling QD decay into plasmon mode using a numerical model based on finite elemental method (FEM). Symmetric gap waveguide considered in this paper support single mode and QD as a dipole emitter. 2D simulation models are done to find normalized Гpl and 3D models are used to find probability of SE decaying into plasmon mode ( β) including all three decay channels. It is found out that changing gap height can increase QD-plasmon coupling, by up to a factor of 5 and optimally placed QD up to a factor of 8. To make the paper more realistic we briefly studied the effect of sharpness of the waveguide edge on SE emission into guided plasmon mode. Preliminary nano gap waveguide fabrication and testing are already underway. Authors expect to compare the theoretical results with experimental outcomes in the future
Resumo:
Polybrominated diphenyl ethers (PBDEs) are a class of brominated flame retardants (BFRs) once extensively used in the plastics of a wide range of consumer products. The listing of certain congeners that are constituents of commercial PBDE mixtures (including c-octaBDE) in the Stockholm Convention and tightening regulation of many other BFRs in recent years have created the need for a rapid and effective method of identifying BFR-containing plastics. A three-tiered testing strategy comparing results from non-destructive testing (X-ray fluorescence (XRF)) (n = 1714), a surface wipe test (n = 137) and destructive chemical analysis (n = 48) was undertaken to systematically identify BFRs in a wide range of consumer products. XRF rapidly identified bromine in 92% of products later confirmed to contain BFRs. Surface wipes of products identified tetrabromobisphenol A (TBBPA), c-octaBDE congeners and BDE-209 with relatively high accuracy (> 75%) when confirmed by destructive chemical analysis. A relationship between the amounts of BFRs detected in surface wipes and subsequent destructive testing shows promise in predicting not only the types of BFRs present but also estimating the concentrations present. Information about the types of products that may contain persistent BFRs will assist regulators in implementing policies to further reduce the occurrence of these chemicals in consumer products.
Resumo:
Understanding the complex nature of diseased tissue in vivo requires development of more advanced nanomedicines, where synthesis of multifunctional polymers combines imaging multimodality with a biocompatible, tunable, and functional nanomaterial carrier. Here we describe the development of polymeric nanoparticles for multimodal imaging of disease states in vivo. The nanoparticle design utilizes the abundant functionality and tunable physicochemical properties of synthetically robust polymeric systems to facilitate targeted imaging of tumors in mice. For the first time, high-resolution 19F/1H magnetic resonance imaging is combined with sensitive and versatile fluorescence imaging in a polymeric material for in vivo detection of tumors. We highlight how control over the chemistry during synthesis allows manipulation of nanoparticle size and function and can lead to very high targeting efficiency to B16 melanoma cells, both in vitro and in vivo. Importantly, the combination of imaging modalities within a polymeric nanoparticle provides information on the tumor mass across various size scales in vivo, from millimeters down to tens of micrometers.
Resumo:
Objective To develop a child victimization survey among a diverse group of child protection experts and examine the performance of the instrument through a set of international pilot studies. Methods The initial draft of the instrument was developed after input from scientists and practitioners representing 40 countries. Volunteers from the larger group of scientists participating in the Delphi review of the ICAST P and R reviewed the ICAST C by email in 2 rounds resulting in a final instrument. The ICAST C was then translated and back translated into six languages and field tested in four countries using a convenience sample of 571 children 12–17 years of age selected from schools and classrooms to which the investigators had easy access. Results The final ICAST C Home has 38 items and the ICAST C Institution has 44 items. These items serve as screeners and positive endorsements are followed by queries for frequency and perpetrator. Half of respondents were boys (49%). Endorsement for various forms of victimization ranged from 0 to 51%. Many children report violence exposure (51%), physical victimization (55%), psychological victimization (66%), sexual victimization (18%), and neglect in their homes (37%) in the last year. High rates of physical victimization (57%), psychological victimization (59%), and sexual victimization (22%) were also reported in schools in the last year. Internal consistency was moderate to high (alpha between .685 and .855) and missing data low (less than 1.5% for all but one item). Conclusions In pilot testing, the ICAST C identifies high rates of child victimization in all domains. Rates of missing data are low, and internal consistency is moderate to high. Pilot testing demonstrated the feasibility of using child self-report as one strategy to assess child victimization. Practice implications The ICAST C is a multi-national, multi-lingual, consensus-based survey instrument. It is available in six languages for international research to estimate child victimization. Assessing the prevalence of child victimization is critical in understanding the scope of the problem, setting national and local priorities, and garnering support for program and policy development aimed at child protection.
Resumo:
Graphene films were produced by chemical vapor deposition (CVD) of pyridine on copper substrates. Pyridine-CVD is expected to lead to doped graphene by the insertion of nitrogen atoms in the growing sp2 carbon lattice, possibly improving the properties of graphene as a transparent conductive film. We here report on the influence that the CVD parameters (i.e., temperature and gas flow) have on the morphology, transmittance, and electrical conductivity of the graphene films grown with pyridine. A temperature range between 930 and 1070 °C was explored and the results were compared to those of pristine graphene grown by ethanol-CVD under the same process conditions. The films were characterized by atomic force microscopy, Raman and X-ray photoemission spectroscopy. The optical transmittance and electrical conductivity of the films were measured to evaluate their performance as transparent conductive electrodes. Graphene films grown by pyridine reached an electrical conductivity of 14.3 × 105 S/m. Such a high conductivity seems to be associated with the electronic doping induced by substitutional nitrogen atoms. In particular, at 930 °C the nitrogen/carbon ratio of pyridine-grown graphene reaches 3%, and its electrical conductivity is 40% higher than that of pristine graphene grown from ethanol-CVD.