265 resultados para Magnetic resonance
Resumo:
BACKGROUND AND PURPOSE Inflammation is a recognized risk factor for the vulnerable atherosclerotic plaque. The study explores the relationship between the degree of Magnetic Resonance (MR)"defined inflammation using Ultra Small Super-Paramagnetic Iron Oxide (USPIO) particles and the severity of luminal stenosis in asymptomatic carotid plaques. METHODS Seventy-one patients with an asymptomatic carotid stenosis of ĝ‰¥40% underwent multi-sequence USPIO-enhanced MR imaging. Stenosis severity was measured according to the NASCET and ECST methods. RESULTS No demonstrable relationship between inflammation as measured by USPIO-enhanced signal change and the degree of luminal stenosis was found. CONCLUSIONS Inflammation and stenosis are likely to be independent risk factors, although this needs to be further validated.
Resumo:
Background Because many acute cerebral ischemic events are caused by rupture of vulnerable carotid atheroma and subsequent thrombosis, the present study used both idealized and patient-specific carotid atheromatous plaque models to evaluate the effect of structural determinants on stress distributions within plaque. Methods and Results Using a finite element method, structural analysis was performed using models derived from in vivo high-resolution magnetic resonance imaging (MRI) of carotid atheroma in 40 non-consecutive patients (20 symptomatic, 20 asymptomatic). Plaque components were modeled as hyper-elastic materials. The effects of varying fibrous cap thickness, lipid core size and lumen curvature on plaque stress distributions were examined. Lumen curvature and fibrous cap thickness were found to be major determinants of plaque stress. The size of the lipid core did not alter plaque stress significantly when the fibrous cap was relatively thick. The correlation between plaque stress and lumen curvature was significant for both symptomatic (p = 0.01; correlation coefficient: 0.689) and asymptomatic patients (p = 0.01; correlation coefficient: 0.862). Lumen curvature in plaques of symptomatic patients was significantly larger than those of asymptomatic patients (1.50±1.0mm-1 vs 1.25±0.75 mm-1; p = 0.01). Conclusion Specific plaque morphology (large lumen curvature and thin fibrous cap) is closely related to plaque vulnerability. Structural analysis using high-resolution MRI of carotid atheroma may help in detecting vulnerable atheromatous plaque and aid the risk stratification of patients with carotid disease.
Resumo:
Arterial compliance has been shown to correlate well with overall cardiovascular outcome and it may also be a potential risk factor for the development of atheromatous disease. This study assesses the utility of 2-D phase contrast Magnetic Resonance (MR) imaging with intra-sequence blood pressure measurement to determine carotid compliance and distensibility. 20 patients underwent 2-D phase contrast MR imaging and also ultrasound-based wall tracking measurements. Values for carotid compliance and distensibility were derived from the two different modalities and compared. Linear regression analysis was utilised to determine the extent of correlation between MR and ultrasound derived parameters. In those variables that could be directly compared, an agreement analysis was undertaken. MR measures of compliance showed a good correlation with measures based on ultrasound wall-tracking (r=0.61, 95% CI 0.34 to 0.81 p=0.0003). Vessels that had undergone carotid endarterectomy previously were significantly less compliant than either diseased or normal contralateral vessels (p=0.04). Agreement studies showed a relatively poor intra-class correlation coefficient (ICC) between diameter-based measures of compliance through either MR or ultrasound (ICC=0.14). MRI based assessment of local carotid compliance appears to be both robust and technically feasible in most subjects. Measures of compliance correlate well with ultrasound-based values and correlate best when cross-sectional area change is used rather than derived diameter changes. If validated by further larger studies, 2-D phase contrast imaging with intra-sequence blood pressure monitoring and off-line radial artery tonometry may provide a useful tool in further assessment of patients with carotid atheroma.
Resumo:
BACKGROUND AND PURPOSE It is well known that the vulnerable atheromatous plaque has a thin, fibrous cap and large lipid core with associated inflammation. This inflammation can be detected on MRI with use of a contrast medium, Sinerem, an ultrasmall superparamagnetic iron oxide (USPIO). Although the incidence of macrophage activity in asymptomatic disease appears low, we aimed to explore the incidence of MRI-defined inflammation in asymptomatic plaques in patients with known contralateral symptomatic disease. METHODS Twenty symptomatic patients underwent multisequence MRI before and 36 hours after USPIO infusion. Images were manually segmented into quadrants, and the signal change in each quadrant was calculated after USPIO administration. A mixed mathematical model was developed to compare the mean signal change across all quadrants in the 2 groups. Patients had a mean symptomatic stenosis of 77% compared with 46% on their asymptomatic side, as measured by conventional angiography. RESULTS There were 11 (55%) men, and the median age was 72 years (range, 53 to 84 years). All patients had risk factors consistent with severe atherosclerotic disease. All symptomatic carotid stenoses had inflammation, as evaluated by USPIO-enhanced imaging. On the contralateral sides, inflammatory activity was found in 19 (95%) patients. Contralaterally, there were 163 quadrants (57%) with a signal loss after USPIO when compared with 217 quadrants (71%) on the symptomatic side (P=0.007). CONCLUSIONS - This study adds weight to the argument that atherosclerosis is a truly systemic disease. It suggests that investigation of the contralateral side in patients with symptomatic carotid stenosis can demonstrate inflammation in 95% of plaques, despite a mean stenosis of only 46%. Thus, inflammatory activity may be a significant risk factor in asymptomatic disease in patients who have known contralateral symptomatic disease. Patients with symptomatic carotid disease should have their contralateral carotid artery followed up.
Resumo:
The stable free radical 1,1,3,3-tetramethylisoindolin-2-yloxyl (TMIO) has proved to be very suitable for use as a spin probe for a number of applications. Because it is soluble mainly in non-polar liquids, there is a need for new derivatives that can be used in a variety of environments. This has been done by introducing substituents in the 5-position of the aromatic ring, namely carboxyl (CTMIO), trimethylamino (TMTMIOI) and sodium sulphonate (NaTMIOS). An accurate ESR method was developed for the measurement of partition coefficients in n-octanol–water. For comparison purposes the method was also applied to some Tempo derivatives. The effect of temperature on the rotational correlation times and the nitrogen-14 hyperfine coupling constant of some of the spin probes was investigated. There is evidence for dimerization of CTMIO to form a biradical
Resumo:
Study design Anterior and posterior vertebral body heights were measured from sequential MRI scans of adolescent idiopathic scoliosis (AIS) patients and healthy controls. Objective To measure changes in vertebral body height over time during scoliosis progression to assess how vertebral body height discrepancies change during growth. Summary of background data Relative anterior overgrowth has been proposed as a potential driver for AIS initiation and progression. This theory proposes that the anterior column grows faster, and the posterior column slower, in AIS patients when compared to healthy controls. There is disagreement in the literature as to whether the anterior vertebral body heights are proportionally greater than posterior vertebral body heights in AIS patients when compared to healthy controls. To some extent, these discrepancies may be attributed to methodological differences. Methods MRI scans of the major curve of 21 AIS patients (mean age 12.5 ± 1.4 years, mean Cobb 32.2 ± 12.8º) and between T4 and T12 of 21 healthy adolescents (mean age 12.1 ± 0.5 years) were captured for this study. Of the 21 AIS patients, 14 had a second scan on average 10.8 ± 4.7 months after the first. Anterior and posterior vertebral body heights were measured from the true sagittal plane of each vertebra such that anterior overgrowth could be quantified. Results The difference between anterior and posterior vertebral body height in healthy, non-scoliotic children was significantly greater than in AIS patients with mild to moderate scoliosis. However there was no significant relationship between the overall anterior-posterior vertebral body height difference in AIS and either severity of the curve or its progression over time. Conclusions Whilst AIS patients have a proportionally longer anterior column than non-scoliotic controls, the degree of anterior overgrowth was not related to the rate of progression or the severity of the scoliotic curve.
Resumo:
Burn injury is a prevalent and traumatic event for pediatric patients. At present, the diagnosis of burn injury severity is subjective and lacks a clinically relevant quantitative measure. This is due in part to a lack of knowledge surrounding the biochemistry of burn injuries and that of blister fluid. A more complete understanding of the blister fluid biochemistry may open new avenues for diagnostic and prognostic development. Burn insult induces a highly complex network of signaling processes and numerous changes within various biochemical systems, which can ultimately be examined using proteome and metabolome measurements. This review reports on the current understanding of burn wound biochemistry and outlines a technical approach for ‘omics’ profiling of blister fluid from burn wounds of differing severity.
Resumo:
Associations between injury and muscle asymmetries, as determined with magnetic resonance (MR) imaging, have been investigated in a number of sports medicine-based studies. For interventional or prospective studies into musculoskeletal injuries, it is important to determine the repeatability of the morphometric procedures used for quantifying muscle asymmetries. This study examines the intra-observer repeatability of manual segmentation for determining bilateral volumes of the individual hamstring muscles.
Resumo:
This paper presents a validation study on the application of a novel interslice interpolation technique for musculoskeletal structure segmentation of articulated joints and muscles on human magnetic resonance imaging data. The interpolation technique is based on morphological shape-based interpolation combined with intensity based voxel classification. Shape-based interpolation in the absence of the original intensity image has been investigated intensively. However, in some applications of medical image analysis, the intensity image of the slice to be interpolated is available. For example, when manual segmentation is conducted on selected slices, the segmentation on those unselected slices can be obtained by interpolation. We proposed a two- step interpolation method to utilize both the shape information in the manual segmentation and local intensity information in the image. The method was tested on segmentations of knee, hip and shoulder joint bones and hamstring muscles. The results were compared with two existing interpolation methods. Based on the calculated Dice similarity coefficient and normalized error rate, the proposed method outperformed the other two methods.
Resumo:
A one-step thermal extrusion process has been investigated for the modification of starch with alcohol in order to improve the film properties. Unmodified starch/glycerol mixtures containing Methanol (MetOH), ethanol (EtOH) and their combinations (5, 10 and 15 wt%) were thermally extruded to produce thermoplastic. The final hot-pressed film showed increased stiffness and crystallinity, while having decreased moisture uptake due to oxidation and alcohol complexing molecular interactions. The Young’s Modulus, tensile strength and elongation at break increased by 60%, 15% and 32% respectively, for 5 wt% MetOH derived film, compared to the control. The film moisture content was reduced by up to 15 wt% for 5 wt% EtOH-derived film. Generally the crystallinity increased in the alcohol-derived films due to an increased complexing of alcohol with starch forming the VH polymorph. Fourier transform infra-red (FTIR) and proton nuclear magnetic resonance (1HNMR) spectroscopic analysis were used to discuss the molecular interactions between the starch and alcohol molecules.