407 resultados para förskollärares arbetssituation under lunchmåltiden.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under seismic loads neither the response of the pile nor the response of ground are independent of each other, contrary what is normally assumed. In seismic design of buildings, dynamic response of a structure is determined by assuming a fixed base on sub-grade and neglecting the physical interaction between foundation and soil profile in which it is embedded. However, the seismic response of pile foundations in vibration sensitive soil profiles is significantly affected by the behaviour of supporting soil. This research uses validated Finite Element techniques to simulate the seismic behaviour of pile foundations embedded in multilayered vibration sensitive soils.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AGL Wholesale Gas Ltd v Origin Energy Ltd [2008] QCA 366 involved an appeal against the setting aside of paragraphs of a subpoena issued under s 17 of the Commercial Arbitration Act 1990 (Qld). The Court was satisfied that even if the documents were of “apparent relevance” to the subject matter of the proceedings, it would nevertheless be oppressive to require their production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Hill v Robertson Suspension Systems Pty Ltd [2009] QDC 165 McGill DCJ considered the procedural requirements for the service of originating process on a company, and for proving that service for the purpose of obtaining default judgment.The judge’s views adopt a strict and technical construction of the requirements for an affidavit of service under r 120(1)(b). Though clearly obiter, they may well affect the approach taken on applications to enter or set aside default judgments in the lower courts. Pending further judicial consideration of the issue, it is suggested the prudent course is to ensure that the deponent of an affidavit for service effected under s 109X(1)(a) of the Act deposes not only to the location of the registered office of the company but also, at a minimum, provides the source of that information.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon fibre reinforced polymer (CFRP) sheets have many outstanding properties such as high strength, high elastic modulus, light weight and good durability which are made them a suitable alternative for steel in strengthening work. This paper describe the ultimate load carrying capacity of steel hollow sections at effective bond length in terms of its cross sectional area and the stress distribution within bond region for different layers CFRP. It was found that depending on their size and orientation of uni- directional CFRP layers, the ultimate tensile load was different. Along with these tests, non linear finite element analysis was also performed to validate the ultimate load carrying capacity depending on their cross sections. The predicted ultimate loads from FE analysis are found very close to the laboratory test results. The validated model has been used to determine the stress distribution at bond joint for different orientation of CFRP. This research shows the effect of stress distribution and suitable wrapping layer to be used for the strengthening of steel hollow sections in tension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Drink driving is a major public health issue and this report examines the experiences of convicted offenders who participated in an established drink driving rehabilitation program Under the Limit (UTL). Course completers were surveyed at least three months after they had finished the 11-week UTL course. The aim of this study was to examine whether the UTL program reduced the level of alcohol consumption either directly as a result of participation in the UTL drink driving program or through increased use of community alcohol program by participants. The research involved a self-report outcome evaluation to determine whether the self-reported levels of alcohol use after the course had changed from the initial alcohol use reported by offenders. The findings are based on the responses of 30 drink-driving offenders who had completed the UTL program (response rate: 20%). While a process evaluation was proposed in the initial application, the low response rate meant that this follow up research was not feasible. The response rate was low for two reasons, it was difficult to: recruit participants who consented to follow up, and subsequently locate and survey those who had consented to involvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fire safety of light gauge steel frame (LSF) stud walls is important in the design of buildings. Currently LSF walls are increasingly used in the building industry, and are usually made of cold-formed and thin-walled steel studs that are fire-protected by two layers of plasterboard on both sides. Many experimental and numerical studies have been undertaken to investigate the fire performance of load bearing LSF walls under standard fire conditions. However, the standard time-temperature curve does not represent the fire load present in typical residential and commercial buildings that include considerable amount of thermoplastic materials. Real building fires are unlikely to follow a standard time-temperature curve. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under realistic design fire conditions. Therefore in this research, finite element thermal models of the traditional LSF wall panels without cavity insulation and the new LSF composite wall panels were developed to simulate their fire performance under recently developed realistic design fire curves. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and literature review. The developed models were then validated by comparing their thermal performance results with available results from realistic design fire tests, and were later used in parametric studies. This paper presents the details of the developed finite element thermal models of load bearing LSF wall panels under realistic design fire time-temperature curves and the re-sults. It shows that finite element thermal models can be used to predict the fire performance of load bearing LSF walls with varying configurations of insulations and plasterboards under realistic design fires. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the time-course and post-receptoral pathway signaling of photoreceptor interactions when the rod (R) and three cone (L, M, S) photoreceptor classes contribute to mesopic vision. A four-primary photostimulator independently controls photoreceptor activity in human observers. The first experiment defines the temporal adaptation response of receptoral (L-, S-cone, rod) and post-receptoral (LMS, LMSR,+L-M) signaling and interactions. Here we show that nonopponent cone-cone interactions (L-cone, LMS, LMSR) have monophasic temporal response patterns whereas opponent signals (+L-M, S-cone) show biphasic response patterns with slower recovery. By comparison, rod-cone interactions with nonopponent signals have faster adaptation responses and reduced sensitivity loss whereas opponent rod-cone interactions are small or absent. Additionally, the rod-rod interaction differs from these interaction types and acts to increase rod sensitivity due to temporal summation but with a slower time course. The second experiment shows that the temporal profile of the rod signal alters the relative rod contributions to the three primary post-receptoral pathways. We demonstrate that rod signals generate luminance (þLþM) signals mediated via the MC pathway with all rod temporal profiles and chromatic signals (L/LþM, S/LþM) in both the PC and KC pathways with durations .75 ms. Thus, we propose that the change in relative weighting of rod signals within the post-receptoral pathways contributes to the sensitivity and temporal response of rod and cone pathway signaling and interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the introduction of Medicare in 1984, the proportion of the Australian population with private health insurance has declined considerably. Insurance for health care consumption is compulsory for the public health sector but optional for the private health sector. In this paper, we explore a number of important issues in the demand for private health insurance in Australia. The socio-economic variables which influence demand are examined using a binary logic model. A number of simulations are performed to highlight the influence and relative importance of various characteristics such as age, income, health status and geographical location on demand. A number of important policy issues in the private health insurance market are highlighted. First, evidence is provided of adverse selection in the private health insurance pool, second, the notion of the wealthy uninsured is refuted, and finally it is confirmed that there are significant interstate differences in the demand for private health insurance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morris' (1986) analysis of the factors affecting project success and failure is considered in relation to the psychology of judgement under uncertainty. A model is proposed whereby project managers may identify the specific circumstances in which human decision-making is prone to systematic error, and hence may apply a number of de-biasing techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Section 14(4) of the Human Fertilisation and Embryology Act 2008 imposes – within the general licensing conditions listed in the Human Fertilisation and Embryology Act 1990 – a prohibition to prevent the selection and implantation of embryos for the purpose of creating a child who will be born with a “serious disability.” This article offers a perspective that demonstrates the problematic nature of the consultation, review, and legislative reform process surrounding s 14(4). The term “serious disability” is not defined within the legislation, but we highlight the fact that s 14(4) was passed with the case of selecting deaf children in mind. We consider some of the literature on the topic of disability and deafness, which, we think, casts some doubt on the view that deafness is a “serious disability.” The main position we advance is that the lack of serious engagement with alternative viewpoints during the legislative process was unsatisfactory. We argue that the contested nature of deafness necessitates a more robust consultation process and a clearer explanation and defence of the normative position that underpins s 14(4).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold-formed steel lipped channels are commonly used in LSF wall construction as load bearing studs with plasterboards on both sides. Under fire conditions, cold-formed thin-walled steel sections heat up quickly resulting in fast reduction in their strength and stiffness. Usually the LSF wall panels are subjected to fire from one side which will cause thermal bowing, neutral axis shift and magnification effects due to the development of non-uniform temperature distributions across the stud. This will induce an additional bending moment in the stud and hence the studs in LSF wall panels should be designed as a beam column considering both the applied axial compression load and the additional bending moment. Traditionally the fire resistance rating of these wall panels is based on approximate prescriptive methods. Very often they are limited to standard wall configurations used by the industry. Therefore a detailed research study is needed to develop fire design rules to predict the failure load and hence the failure time of LSF wall panels subject to non-uniform temperature distributions. This paper presents the details of an investigation to develop suitable fire design rules for LSF wall studs under non-uniform elevated temperature distributions. Applications of the previously developed fire design rules based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 to LSF wall studs were investigated in detail and new simplified fire design rules based on AS/NZS 4600 and Eurocode 3 Part 1.3 were proposed in the current study with suitable allowances for the interaction effects of compression and bending actions. The accuracy of the proposed fire design rules was verified by using the results from full scale fire tests and extensive numerical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light Gauge Steel Framing (LSF) walls are made of cold-formed, thin-walled steel lipped channel studs with plasterboard linings on both sides. However, these thin-walled steel sections heat up quickly and lose their strength under fire conditions despite the protection provided by plasterboards. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. A research study using both fire tests and numerical studies was undertaken to investigate the structural and thermal behaviour of load bearing LSF walls made of both conventional and the new composite panels under standard fire conditions and to determine their fire resistance rating. This paper presents the details of finite element models of LSF wall studs developed to simulate the structural performance of LSF wall panels under standard fire conditions. Finite element analyses were conducted under both steady and transient state conditions using the time-temperature profiles measured during the fire tests. The developed models were validated using the fire test results of 11 LSF wall panels with various plasterboard/insulation configurations and load ratios. They were able to predict the fire resistance rating within five minutes. The use of accurate numerical models allowed the inclusion of various complex structural and thermal effects such as local buckling, thermal bowing and neutral axis shift that occurred in thin-walled steel studs under non-uniform elevated temperature conditions. Finite element analyses also demonstrated the improvements offered by the new composite panel system over the conventional cavity insulated system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold–formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.