279 resultados para Heart Parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent developments in wearable ECG technology have seen renewed interest in the use of Heart Rate Variability (HRV) feedback for stress management. Yet, little is know about the efficacy of such interventions. Positive reappraisal is an emotion regulation strategy that involves changing the way a situation is construed to decrease emotional impact. We sought to test the effectiveness of an intervention that used feedback on HRV data to prompt positive reappraisal during a stressful work task. Participants (N=122) completed two 20-minute trials of an inbox activity. In-between the first and the second trial participants were assigned to the waitlist control condition, a positive reappraisal via psycho-education condition, or a positive reappraisal via HRV feedback condition. Results revealed that using HRV data to frame a positive reappraisal message is more effective than using psycho-education (or no intervention)–especially for increasing positive mood and reducing arousal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Hallux valgus (HV) has been linked to functional disability and increased falls risk in older adults. However, specific gait alterations in individuals with HV are unclear. This systematic review investigated gait parameters associated with HV in otherwise healthy adults. Methods Electronic databases (Medline, Embase, CINAHL) were searched to October 2011, including cross-sectional studies with clearly defined HV and non-HV comparison groups. Two investigators independently rated studies for methodological quality. Effect sizes (95% confidence intervals (CI)) were calculated as standardized mean differences (SMD) for continuous data and risk ratios (RR) for dichotomous data. Results Nine studies included a total of 589 participants. Three plantar pressure studies reported increased hallux loading (SMD 0.56 to 1.78) and medial forefoot loading (SMD 0.62 to 1.21), while one study found reduced first metatarsal loading (SMD −0.61, CI −1.19 to −0.03) in HV participants. HV participants demonstrated less ankle and rearfoot motion during terminal stance (SMD −0.81 to −0.63) and increased intrinsic muscle activity (RR 1.6, 1.1 to 2.2). Most studies reported no differences in spatio-temporal parameters; however, one study found reduced speed (SMD −0.73, -1.25 to −0.20), step length (SMD −0.66 to −0.59) and less stable gait patterns (SMD −0.86 to −0.78) in older adults with HV. Conclusions HV impacts on particular gait parameters, and further understanding of potentially modifiable factors is important for prevention and management of HV. Cause and effect relationships cannot be inferred from cross-sectional studies, thus prospective studies are warranted to elucidate the relationship between HV and functional disability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Trials of new technologies to remotely monitor for signs and symptoms of worsening heart failure are continually emerging. The extent to which technological differences impact the effectiveness of non-invasive remote monitoring for heart failure management is unknown. Objective To examine the effect of specific technology used for non-invasive remote monitoring of people with heart failure on all-cause mortality and heart failure-related hospitalisations. Methods A sub-analysis of a large systematic review and meta-analysis was conducted. Studies were stratified according to the specific type of technology used and separate meta-analyses were performed. Four different types of non-invasive remote monitoring technologies were identified including structured telephone calls, videophone, interactive voice response devices and telemonitoring. Results Only structured telephone calls and telemonitoring were effective in reducing the risk of all-cause mortality (RR 0.87; 95% CI=0.75-1.01; p=0.06 and 0.62; 95% CI=0.50-0.77; p<0.0001) and heart failure-related hospitalisations (RR 0.77; 95% CI=0.68-0.87; p<0.001) and 0.75; 95% CI=0.63-0.91; p=0.003). More research data is required for videophone and interactive voice response technologies. Conclusions This sub-analysis identified that only two of the four specific technologies used for non-invasive remote monitoring in heart failure improved outcomes. When results of studies that involved these disparate technologies were combined in previous meta-analyses, significant improvements in outcomes were identified. As such, this study has highlighted implications for future meta-analyses of randomised controlled trials focused on evaluating the effectiveness of remote monitoring in heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Commercially available instrumented treadmill systems that provide continuous measures of temporospatial gait parameters have recently become available for clinical gait analysis. This study evaluated the level of agreement between temporospatial gait parameters derived from a new instrumented treadmill, which incorporated a capacitance-based pressure array, with those measured by a conventional instrumented walkway (criterion standard). Methods Temporospatial gait parameters were estimated from 39 healthy adults while walking over an instrumented walkway (GAITRite®) and instrumented treadmill system (Zebris) at matched speed. Differences in temporospatial parameters derived from the two systems were evaluated using repeated measures ANOVA models. Pearson-product-moment correlations were used to investigate relationships between variables measured by each system. Agreement was assessed by calculating the bias and 95% limits of agreement. Results All temporospatial parameters measured via the instrumented walkway were significantly different from those obtained from the instrumented treadmill (P < .01). Temporospatial parameters derived from the two systems were highly correlated (r, 0.79–0.95). The 95% limits of agreement for temporal parameters were typically less than ±2% of gait cycle duration. However, 95% limits of agreement for spatial measures were as much as ±5 cm. Conclusions Differences in temporospatial parameters between systems were small but statistically significant and of similar magnitude to changes reported between shod and unshod gait in healthy young adults. Temporospatial parameters derived from an instrumented treadmill, therefore, are not representative of those obtained from an instrumented walkway and should not be interpreted with reference to literature on overground walking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction forces measured by a treadmill system instrumented with a capacitance–based pressure platform. Methods Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. Results There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. Conclusions The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Post-heart transplant psychological distress may both directly hinder physiological health as well as indirectly impact on clinical outcomes by increasing unhealthy behaviours, such as immunosuppression non-adherence. Reducing psychological distress for heart transplant recipients is therefore vitally important, in order to improve patients’ overall health and well-being but also clinical outcomes, such as morbidity and mortality. Evidence from other populations suggests that non-pharmacological interventions may be an effective strategy. Aim To appraise the efficacy of non-pharmacological interventions on psychological outcomes after heart transplant. Method A systematic review was conducted using the Joanna Briggs Institute methodology. Experimental and quasi-experimental studies that involved any non-pharmacological intervention for heart transplant recipients were included, provided that data on psychological outcomes were reported. Multiple electronic databases were searched for published and unpublished studies and reference lists of retrieved studies were scrutinized for further primary research. Data were extracted using a standardised data extraction tool. Included studies were assessed by two independent reviewers using standardised critical appraisal instruments. Results Three studies fulfilled the inclusion and exclusion criteria, which involved only 125 heart transplant recipients. Two studies reported on exercise programs. One study reported a web-based psychosocial intervention. While psychological outcomes significantly improved from baseline to follow-up for the recipients who received the interventions, between-group comparisons were not reported. The methodological quality of the studies was judged to be poor. Conclusions Further research is required, as we found there is insufficient evidence available to draw conclusions for or against the use of non-pharmacological interventions after heart transplant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carrying capacity assessments model a population’s potential self-sufficiency. A crucial first step in the development of such modelling is to examine the basic resource-based parameters defining the population’s production and consumption habits. These parameters include basic human needs such as food, water, shelter and energy together with climatic, environmental and behavioural characteristics. Each of these parameters imparts land-usage requirements in different ways and varied degrees so their incorporation into carrying capacity modelling also differs. Given that the availability and values of production parameters may differ between locations, no two carrying capacity models are likely to be exactly alike. However, the essential parameters themselves can remain consistent so one example, the Carrying Capacity Dashboard, is offered as a case study to highlight one way in which these parameters are utilised. While examples exist of findings made from carrying capacity assessment modelling, to date, guidelines for replication of such studies in other regions and scales have largely been overlooked. This paper addresses such shortcomings by describing a process for the inclusion and calibration of the most important resource-based parameters in a way that could be repeated elsewhere.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total Artificial Hearts are mechanical pumps which can be used to replace the failing natural heart. This novel study developed a means of controlling a new design of pump to reproduce physiological flow bringing closer the realisation of a practical artificial heart. Using a mathematical model of the device, an optimisation algorithm was used to determine the best configuration for the magnetic levitation system of the pump. The prototype device was constructed and tested in a mock circulation loop. A physiological controller was designed to replicate the Frank-Starling like balancing behaviour of the natural heart. The device and controller provided sufficient support for a human patient while also demonstrating good response to various physiological conditions and events. This novel work brings the design of a practical artificial heart closer to realisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach is proposed for obtaining a non-linear area-based equivalent model of power systems to express the inter-area oscillations using synchronised phasor measurements. The generators that remain coherent for inter-area disturbances over a wide range of operating conditions define the areas, and the reduced model is obtained by representing each area by an equivalent machine. The parameters of the reduced system are identified by processing the obtained measurements, and a non-linear Kalman estimator is then designed for the estimation of equivalent area angles and frequencies. The simulation of the approach on a two-area system shows substantial reduction of non-inter-area modes in the estimated angles. The proposed methods are also applied to a ten-machine system to illustrate the feasibility of the approach on larger and meshed networks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Research on engineering design is a core area of concern within engineering education and a fundamental understanding of how engineering students approach and undertake design is necessary in order to develop effective design models and pedagogies. Understanding the factors related to design experiences in education and how they affect student practice can help educators as well as designers to leverage these factors as part of the design process. PURPOSE This study investigated the design practices of first-year engineering students’ and their experiences with a first-year engineering course design project. The research questions that guided the investigation were: 1. From a student perspective, what design parameters or criteria are most important? 2. How does this perspective impact subsequent student design practice throughout the design process? DESIGN/METHOD The authors employed qualitative multi-case study methods (Miles & Huberman, 1994) in order to the answer the research questions. Participant teams were observed and video recorded during team design meetings in which they researched the background for the design problem, brainstormed and sketched possible solutions, as well as built prototypes and final models of their design solutions as part of a course design project. Analysis focused on explanation building (Yin, 2009) and utilized within-case and cross-case analysis (Miles & Huberman, 1994). RESULTS We found that students focused disproportionally on the functional parameter, i.e. the physical implementation of their solution, and the possible/applicable parameter, i.e. a possible and applicable solution that benefited the user, in comparison to other given parameters such as safety and innovativeness. In addition, we found that individual teams focused on the functional and possible/ applicable parameters in early design phases such as brainstorming/ ideation and sketching. When prompted to discuss these non-salient parameters (from the student perspective) in the final design report, student design teams often used a post-hoc justification to support how the final designs fit the parameters that they did not initially consider. CONCLUSIONS This study suggests is that student design teams become fixated on (and consequently prioritize) certain parameters they interpret as important because they feel these parameters were described more explicitly in terms how they were met and assessed. Students fail to consider other parameters, perceived to be less directly assessable, unless prompted to do so. Failure to consider other parameters in the early design phases subsequently affects their approach in design phases as well. Case studies examining students’ study strategies within three Australian Universities illustrate similarities with some student approaches to design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims This paper is a report on the effectiveness of a self-management programme based on the self-efficacy construct, in older people with heart failure. Background Heart failure is a major health problem worldwide, with high mortality and morbidity, making it a leading cause of hospitalization. Heart failure is associated with a complex set of symptoms that arise from problems in fluid and sodium retention. Hence, managing salt and fluid intake is important and can be enhanced by improving patients' self-efficacy in changing their behaviour. Design Randomized controlled trial. Methods Heart failure patients attending cardiac clinics in northern Taiwan from October 2006–May 2007 were randomly assigned to two groups: control (n = 46) and intervention (n = 47). The intervention group received a 12-week self-management programme that emphasized self-monitoring of salt/fluid intake and heart failure-related symptoms. Data were collected at baseline as well as 4 and 12 weeks later. Data analysis to test the hypotheses used repeated-measures anova models. Results Participants who received the intervention programme had significantly better self-efficacy for salt and fluid control, self-management behaviour and their heart failure-related symptoms were significantly lower than participants in the control group. However, the two groups did not differ significantly in health service use. Conclusion The self-management programme improved self-efficacy for salt and fluid control, self-management behaviours, and decreased heart failure-related symptoms in older Taiwanese outpatients with heart failure. Nursing interventions to improve health-related outcomes for patients with heart failure should emphasize self-efficacy in the self-management of their disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Sleep disturbances, including insomnia and sleep-disordered breathing, are a common complaint in people with heart failure and impair well-being. Exercise training (ET) improves quality of life in stable heart failure patients. ET also improves sleep quality in healthy older patients, but there are no previous intervention studies in heart failure patients. Aim The aim of this study was to examine the impact of ET on sleep quality in patients recently discharged from hospital with heart failure. Methods This was a sub-study of a multisite randomised controlled trial. Participants with a heart failure hospitalisation were randomised within six weeks of discharge to a 12-week disease management programme including exercise advice (n=52) or to the same programme with twice weekly structured ET (n=54). ET consisted of two one-hour supervised aerobic and resistance training sessions, prescribed and advanced by an exercise specialist. The primary outcome was change in Pittsburgh Sleep Quality Index (PSQI) between randomisation and week 12. Results At randomisation, 45% of participants reported poor sleep (PSQI≥5). PSQI global score improved significantly more in the ET group than the control group (–1.5±3.7 vs 0.4±3.8, p=0.03). Improved sleep quality correlated with improved exercise capacity and reduced depressive symptoms, but not with changes in body mass index or resting heart rate. Conclusion Twelve weeks of twice-weekly supervised ET improved sleep quality in patients recently discharged from hospital with heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

G protein-coupled receptors (GPCRs) are critical for cardiovascular physiology. Cardiac cells express >100 nonchemosensory GPCRs, indicating that important physiological and potential therapeutic targets remain to be discovered. Moreover, there is a growing appreciation that members of the large, distinct taste and odorant GPCR families have specific functions in tissues beyond the oronasal cavity, including in the brain, gastrointestinal tract and respiratory system. To date, these chemosensory GPCRs have not been systematically studied in the heart. We performed RT-qPCR taste receptor screens in rodent and human heart tissues that revealed discrete subsets of type 2 taste receptors (TAS2/Tas2) as well as Tas1r1 and Tas1r3 (comprising the umami receptor) are expressed. These taste GPCRs are present in cultured cardiac myocytes and fibroblasts, and are enriched in myocytes, which we corroborated using in situ hybridization. Tas1r1 gene-targeted mice (Tas1r1Cre/Rosa26tdRFP) strikingly recapitulated these data. In vivo taste receptor expression levels were developmentally regulated in the postnatal period. Intriguingly, several Tas2rs were upregulated in cultured rat myocytes and in mouse heart in vivo following starvation. The discovery of taste GPCRs in the heart opens an exciting new field of cardiac research. We predict that these taste receptors may function as nutrient sensors in the heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new algorithm based on a Modified Particle Swarm Optimization (MPSO) to estimate the harmonic state variables in a distribution networks. The proposed algorithm performs the estimation for both amplitude and phase of each injection harmonic currents by minimizing the error between the measured values from Phasor Measurement Units (PMUs) and the values computed from the estimated parameters during the estimation process. The proposed algorithm can take into account the uncertainty of the harmonic pseudo measurement and the tolerance in the line impedances of the network as well as the uncertainty of the Distributed Generators (DGs) such as Wind Turbines (WTs). The main features of the proposed MPSO algorithm are usage of a primary and secondary PSO loop and applying the mutation function. The simulation results on 34-bus IEEE radial and a 70-bus realistic radial test networks are presented. The results demonstrate that the speed and the accuracy of the proposed Distribution Harmonic State Estimation (DHSE) algorithm are very excellent compared to the algorithms such as Weight Least Square (WLS), Genetic Algorithm (GA), original PSO, and Honey Bees Mating Optimization (HBMO).