336 resultados para BODY-FLUID SAMPLES
Resumo:
The free surface flow of a finite depth fluid past a semi-infinite body is considered. The fluid is assumed to have constant vorticity throughout and the free surface is assumed to attach smoothly to the front face of the body. Numerical solutions are found using a boundary integral method in the physical plane and it is shown that solutions exist for all supercritical Froude numbers. The related problem of the cusp-like flow due to a submerged sink in a corner is also considered. Vorticity is included in the flow and it is shown that the behaviour of the solutions is qualitatively the same as that found in the problem described above.
Resumo:
Cell based therapies for bone regeneration are an exciting emerging technology, but the availability of osteogenic cells is limited and an ideal cell source has not been identified. Amniotic fluid-derived stem (AFS) cells and bone-marrow derived mesenchymal stem cells (MSCs) were compared to determine their osteogenic differentiation capacity in both 2D and 3D environments. In 2D culture, the AFS cells produced more mineralized matrix but delayed peaks in osteogenic markers. Cells were also cultured on 3D scaffolds constructed of poly-e-caprolactone for 15 weeks. MSCs differentiated more quickly than AFS cells on 3D scaffolds, but mineralized matrix production slowed considerably after 5 weeks. In contrast, the rate of AFS cell mineralization continued to increase out to 15 weeks, at which time AFS constructs contained 5-fold more mineralized matrix than MSC constructs. Therefore, cell source should be taken into consideration when used for cell therapy, as the MSCs would be a good choice for immediate matrix production, but the AFS cells would continue robust mineralization for an extended period of time. This study demonstrates that stem cell source can dramatically influence the magnitude and rate of osteogenic differentiation in vitro.
Resumo:
Pedestrian movement is known to cause significant effects on indoor MIMO channels. In this paper, a statistical characterization of the indoor MIMO-OFDM channel subject ot pedestrian movement is reported. The experiment used 4 sending and 4 receiving antennas and 114 sub-carriers at 5.2 GHz. Measurement scenarios varied from zero to ten pedestrians walking randomly between transmitter (tx) and receiver (Rx) arrays. The empirical cumulative distribution function (CDF) of the received fading envelope fits the Ricean distribution with K factors ranging from 7dB to 15 dB, for the 10 pedestrians and vacant scenarios respectively. In general, as the number of pedestrians increase, the CDF slope tends to decrease proportionally. Furthermore, as the number of pedestrians increase, increasing multipath contribution, the dynamic range of channel capacity increases proportionally. These results are consistent with measurement results obtained in controlled scenarios for a fixed narrowband Single-Input Single-Output (SISO) link at 5.2 GHz in previous work. The described empirical characterization provides an insight into the prediction of human-body shadowing effects for indoor MIMO-OFDM channels at 5.2 GHz.
Resumo:
Objective: To assess the efficacy of maternal betamethasone for improving preterm lung function, in the presence of inflammation induced by amniotic fluid ureaplasma colonization. ----- ----- Study design: Ewes bearing single fetuses were randomized to receive an intra-amniotic injection of Ureaplasma parvum (serovar 6; 2×107 colony forming units) or vehicle at 86±2 days of pregnancy (mean±SD: term is 150d), followed by maternal intramuscular betamethasone (0.5mg/kg) or saline, either 2 or 7 days before delivery of lambs at 123±1d. ----- ----- Results: Amniotic fluid IL-8 was elevated by ureaplasmas (p=0.049) but unaffected by betamethasone. Lung inflammation induced by ureaplasmas was not affected by betamethasone. Lung compliance was increased by ureaplasma colonization (p=0.009) and betamethasone (p=0.042), and effects were additive. Lung surfactant was increased by ureaplasma colonization (p<0.001) and betamethasone 7 days (p=0.001), but not 2 days, before delivery. ----- ----- Conclusion: Inflammation improves preterm lung function due to increases in surfactant. Antenatal corticosteroids further augment lung function, through an apparently independent mechanism.
Resumo:
Magneto-rheological (MR) fluid damper is a semi-active control device that has recently received more attention by the vibration control community. But inherent nonlinear hysteresis character of magneto-rheological fluid dampers is one of the challenging aspects for utilizing this device to achieve high system performance. So the development of accurate model is necessary to take the advantage their unique characteristics. Research by others [3] has shown that a system of nonlinear differential equations can successfully be used to describe the hysteresis behavior of the MR damper. The focus of this paper is to develop an alternative method for modeling a damper in the form of centre average fuzzy interference system, where back propagation learning rules are used to adjust the weight of network. The inputs for the model are used from the experimental data. The resulting fuzzy interference system is satisfactorily represents the behavior of the MR fluid damper with reduced computational requirements. Use of the neuro-fuzzy model increases the feasibility of real time simulation.
Resumo:
A computational fluid dynamics (CFD) analysis has been performed for a flat plate photocatalytic reactor using CFD code FLUENT. Under the simulated conditions (Reynolds number, Re around 2650), a detailed time accurate computation shows the different stages of flow evolution and the effects of finite length of the reactor in creating flow instability, which is important to improve the performance of the reactor for storm and wastewater reuse. The efficiency of a photocatalytic reactor for pollutant decontamination depends on reactor hydrodynamics and configurations. This study aims to investigate the role of different parameters on the optimization of the reactor design for its improved performance. In this regard, more modelling and experimental efforts are ongoing to better understand the interplay of the parameters that influence the performance of the flat plate photocatalytic reactor.
Resumo:
Background Concern about skin cancer is a common reason for people from predominantly fair-skinned populations to present to primary care doctors. Objectives To examine the frequency and body-site distribution of malignant, pre-malignant and benign pigmented skin lesions excised in primary care. Methods This prospective study conducted in Queensland, Australia, included 154 primary care doctors. For all excised or biopsied lesions, doctors recorded the patient's age and sex, body site, level of patient pressure to excise, and the clinical diagnosis. Histological confirmation was obtained through pathology laboratories. Results Of 9650 skin lesions, 57·7% were excised in males and 75·0% excised in patients ≥50years. The most common diagnoses were basal cell carcinoma (BCC) (35·1%) and squamous cell carcinoma (SCC) (19·7%). Compared with the whole body, the highest densities for SCC, BCC and actinic keratoses were observed on chronically sun-exposed areas of the body including the face in males and females, the scalp and ears in males, and the hands in females. The density of BCC was also high on intermittently or rarely exposed body sites. Females, younger patients and patients with melanocytic naevi were significantly more likely to exert moderate/high levels of pressure on the doctor to excise. Conclusions More than half the excised lesions were skin cancer, which mostly occurred on the more chronically sun-exposed areas of the body. Information on the type and body-site distribution of skin lesions can aid in the diagnosis and planned management of skin cancer and other skin lesions commonly presented in primary care.
Resumo:
The hydrodynamic behaviour of a novel flat plate photocatalytic reactor for water treatment is investigated using CFD code FLUENT. The reactor consists of a reactive section that features negligible pressure drop and uniform illumination of the photocatalyst to ensure enhanced photocatalytic efficiency. The numerical simulations allowed the identification of several design issues in the original reactor, which include extensive boundary layer separation near the photocatalyst support and regions of flow recirculation that render a significant portion of the reactive area. The simulations reveal that this issue could be addressed by selecting the appropriate inlet positions and configurations. This modification can cause minimal pressure drop across the reactive zone and achieves significant uniformization of the tested pollutant on the photocatalyst surface. The influence of roughness elements type has also been studied with a view to identify their role on the distribution of pollutant concentration on the photocatalyst surface. The results presented here indicate that the flow and pollutant concentration field strongly depend on the geometric parameters and flow conditions.
Resumo:
A series of experiments have been conducted to determine the flexural, EI, and torsional, GJ, rigidity of an Olympus colonoscope CF‐140S and torsional rigidity of a Pentax colonoscope EC‐3870 and the dependency of these properties on temperature and on the presence of loops. Along the length of the colonoscope, the Olympus colonoscope flexural rigidity varied between 260 and 400 Ncm2 and torsional rigidity varied between 68 and 88 Ncm2/deg, with an average of 76 Ncm2/deg for tests involving 0.86 Nm of anti‐clockwise torque. Results show a significant decrease of 10% in torsional rigidity between clockwise and anti‐clockwise torque. For the Pentax colonoscope flexural rigidity was not tested; its torsional rigidity varied between 34 and 76 Ncm2/deg, with an average of 46 Ncm2/deg for tests involving 0.43 Nm of anti‐clockwise torque. An increase in temperature of the Olympus colonoscope from 24°C to 37°C reduces EI by an average of 17% and GJ by an average of 7%. A right‐handed loop caused a significant increase in flexural rigidity, but other looping configurations had no significant influence.
A simplified invariant line analysis for face-centred cubic/body-centred cubic precipitation systems