177 resultados para second-generation migrants


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart matrices are required in bone tissueengineered grafts that provide an optimal environment for cells and retain osteo-inductive factors for sustained biological activity. We hypothesized that a slow-degrading heparin-incorporated hyaluronan (HA) hydrogel can preserve BMP-2; while an arterio–venous (A–V) loop can support axial vascularization to provide nutrition for a bioartificial bone graft. HA was evaluated for osteoblast growth and BMP-2 release. Porous PLDLLA–TCP–PCL scaffolds were produced by rapid prototyping technology and applied in vivo along with HA-hydrogel, loaded with either primary osteoblasts or BMP-2. A microsurgically created A–V loop was placed around the scaffold, encased in an isolation chamber in Lewis rats. HA-hydrogel supported growth of osteoblasts over 8 weeks and allowed sustained release of BMP-2 over 35 days. The A–V loop provided an angiogenic stimulus with the formation of vascularized tissue in the scaffolds. Bone-specific genes were detected by real time RT-PCR after 8 weeks. However, no significant amount of bone was observed histologically. The heterotopic isolation chamber in combination with absent biomechanical stimulation might explain the insufficient bone formation despite adequate expression of bone-related genes. Optimization of the interplay of osteogenic cells and osteo-inductive factors might eventually generate sufficient amounts of axially vascularized bone grafts for reconstructive surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND. Physical symptoms are common in pregnancy and are predominantly associated with normal physiological changes. These symptoms have a social and economic cost, leading to absenteeism from work and additional medical interventions. There is currently no simple method for identifying common pregnancy related problems in the antenatal period. A validated tool, for use by pregnancy care providers would be useful. AIM: The aim of the project was to develop and validate a Pregnancy Symptoms Inventory for use by healthcare professionals (HCPs). METHODS: A list of symptoms was generated via expert consultation with midwives and obstetrician gynaecologists. Focus groups were conducted with pregnant women in their first, second or third trimester. The inventory was then tested for face validity and piloted for readability and comprehension. For test-re-test reliability, it was administered to the same women 2 to 3 days apart. Finally, outpatient midwives trialled the inventory for 1 month and rated its usefulness on a 10cm visual analogue scale (VAS). The number of referrals to other health care professionals was recorded during this month. RESULTS: Expert consultation and focus group discussions led to the generation of a 41-item inventory. Following face validity and readability testing, several items were modified. Individual item test re-test reliability was between .51 to 1 with the majority (34 items) scoring .0.70. During the testing phase, 211 surveys were collected in the 1 month trial. Tiredness (45.5%), poor sleep (27.5%) back pain (19.5%) and nausea (12.6%) were experienced often. Among the women surveyed, 16.2% claimed to sometimes or often be incontinent. Referrals to the incontinence nurse increased > 8 fold during the study period. The median rating by midwives of the ‘usefulness’ of the inventory was 8.4 (range 0.9 to 10). CONCLUSIONS: The Pregnancy Symptoms Inventory (PSI) was well accepted by women in the 1 month trial and may be a useful tool for pregnancy care providers and aids clinicians in early detection and subsequent treatment of symptoms. It shows promise for use in the research community for assessing the impact of lifestyle intervention in pregnancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In conveyancing of all types, it is very common that a contract will only be formed after often lengthy negotiations which may involve a counter-offer or multiple counter-offers. At common law, the laws of contract that govern these arrangements are well known and well understood. However, the legislative overlay imposed by the requirements of the Property Agents and Motor Dealers Act 2000 (Qld) (‘PAMDA’) can create difficulties as illustrated by the result in Rice v Ray [2009] QDC 275.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studying the rate of cell migration provides insight into fundamental cell biology as well as a tool to assess the functionality of synthetic surfaces and soluble environments used in tissue engineering. The traditional tools used to study cell migration include the fence and wound healing assays. In this paper we describe the development of a microchannel based device for the study of cell migration on defined surfaces. We demonstrate that this device provides a superior tool, relative to the previously mentioned assays, for assessing the propagation rate of cell wave fronts. The significant advantage provided by this technology is the ability to maintain a virgin surface prior to the commencement of the cell migration assay. Here, the device is used to assess rates of mouse fibroblasts (NIH 3T3) and human osteosarcoma (SaOS2) cell migration on surfaces functionalized with various extracellular matrix proteins as a demonstration that confining cell migration within a microchannel produces consistent and robust data. The device design enables rapid and simplistic assessment of multiple repeats on a single chip, where surfaces have not been previously exposed to cells or cellular secretions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the rapid increase in electrical energy demand, power generation in the form of distributed generation is becoming more important. However, the connections of distributed generators (DGs) to a distribution network or a microgrid can create several protection issues. The protection of these networks using protective devices based only on current is a challenging task due to the change in fault current levels and fault current direction. The isolation of a faulted segment from such networks will be difficult if converter interfaced DGs are connected as these DGs limit their output currents during the fault. Furthermore, if DG sources are intermittent, the current sensing protective relays are difficult to set since fault current changes with time depending on the availability of DG sources. The system restoration after a fault occurs is also a challenging protection issue in a converter interfaced DG connected distribution network or a microgrid. Usually, all the DGs will be disconnected immediately after a fault in the network. The safety of personnel and equipment of the distribution network, reclosing with DGs and arc extinction are the major reasons for these DG disconnections. In this thesis, an inverse time admittance (ITA) relay is proposed to protect a distribution network or a microgrid which has several converter interfaced DG connections. The ITA relay is capable of detecting faults and isolating a faulted segment from the network, allowing unfaulted segments to operate either in grid connected or islanded mode operations. The relay does not make the tripping decision based on only the fault current. It also uses the voltage at the relay location. Therefore, the ITA relay can be used effectively in a DG connected network in which fault current level is low or fault current level changes with time. Different case studies are considered to evaluate the performance of the ITA relays in comparison to some of the existing protection schemes. The relay performance is evaluated in different types of distribution networks: radial, the IEEE 34 node test feeder and a mesh network. The results are validated through PSCAD simulations and MATLAB calculations. Several experimental tests are carried out to validate the numerical results in a laboratory test feeder by implementing the ITA relay in LabVIEW. Furthermore, a novel control strategy based on fold back current control is proposed for a converter interfaced DG to overcome the problems associated with the system restoration. The control strategy enables the self extinction of arc if the fault is a temporary arc fault. This also helps in self system restoration if DG capacity is sufficient to supply the load. The coordination with reclosers without disconnecting the DGs from the network is discussed. This results in increased reliability in the network by reduction of customer outages.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Novel profluorescent nitroxides bearing a triazole linker between the coumarin fluorophore and an isoindoline nitroxide were prepared in good yields using the coppercatalyzed azide�alkyne 1,3-dipolar cycloaddition reaction (CuAAC). Nitroxides containing 7-hydroxy and 7-diethylamino substitution on their coumarin rings displayed significant fluorescence suppression, and upon reaction with methyl radicals, normal fluorescence emission was returned. The fluorescence emission for the 7-hydroxycoumarin nitroxide and its diamagnetic analogue was found to be strongly influenced by pH with maximal fluorescence emission achieved in basic solution. Solvent polarity was also shown to affect fluorescence emission. The significant difference in fluorescence output between the nitroxides and their corresponding diamagnetic analogues makes these compounds ideal tools for monitoring processes involving free-radical species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We seek numerical methods for second‐order stochastic differential equations that reproduce the stationary density accurately for all values of damping. A complete analysis is possible for scalar linear second‐order equations (damped harmonic oscillators with additive noise), where the statistics are Gaussian and can be calculated exactly in the continuous‐time and discrete‐time cases. A matrix equation is given for the stationary variances and correlation for methods using one Gaussian random variable per timestep. The only Runge–Kutta method with a nonsingular tableau matrix that gives the exact steady state density for all values of damping is the implicit midpoint rule. Numerical experiments, comparing the implicit midpoint rule with Heun and leapfrog methods on nonlinear equations with additive or multiplicative noise, produce behavior similar to the linear case.