19 resultados para Visual Studio™ 2008

em Universidade do Minho


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em Ensino de Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, road accidents are a major public health problem, which increase is forecasted if road safety is not treated properly, dying about 1.2 million people every year around the globe. In 2012, Portugal recorded 573 fatalities in road accidents, on site, revealing the largest decreasing of the European Union for 2011, along with Denmark. Beyond the impact caused by fatalities, it was calculated that the economic and social costs of road accidents weighted about 1.17% of the Portuguese gross domestic product in 2010. Visual Analytics allows the combination of data analysis techniques with interactive visualizations, which facilitates the process of knowledge discovery in sets of large and complex data, while the Geovisual Analytics facilitates the exploration of space-time data through maps with different variables and parameters that are under analysis. In Portugal, the identification of road accident accumulation zones, in this work named black spots, has been restricted to annual fixed windows. In this work, it is presented a dynamic approach based on Visual Analytics techniques that is able to identify the displacement of black spots on sliding windows of 12 months. Moreover, with the use of different parameterizations in the formula usually used to detect black spots, it is possible to identify zones that are almost becoming black spots. Through the proposed visualizations, the study and identification of countermeasures to this social and economic problem can gain new grounds and thus the decision- making process is supported and improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to advances in information technology (e.g., digital video cameras, ubiquitous sensors), the automatic detection of human behaviors from video is a very recent research topic. In this paper, we perform a systematic and recent literature review on this topic, from 2000 to 2014, covering a selection of 193 papers that were searched from six major scientific publishers. The selected papers were classified into three main subjects: detection techniques, datasets and applications. The detection techniques were divided into four categories (initialization, tracking, pose estimation and recognition). The list of datasets includes eight examples (e.g., Hollywood action). Finally, several application areas were identified, including human detection, abnormal activity detection, action recognition, player modeling and pedestrian detection. Our analysis provides a road map to guide future research for designing automatic visual human behavior detection systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Methods: Nineteen right eyes from 19 myopic patients (average central M ± SD = −2.67 ± 1.66 D) aged 20–27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D®) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. Results: For the naked eye, refractive pattern (M, J0 and J45) across the central 60◦ of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Conclusion: Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To describe the stabilization of early adult-onset myopia in three university students after initiating orthokeratology treatment with corneal refractive therapy contact lenses. Methods: Three Caucasian early adult-onset progressing myopic subjects (1 male, 2 females) were fitted with corneal refractive therapy lenses to correct myopia between ?1.50 and ?2.50 D of sphere using Paragon CRT (Paragon Vision Sciences, Mesa, AZ)lenses for overnight orthokeratology. The pre-treatment refractive history from 2005 as well as refraction and axial length after treatment onset are reported over a period of 3 years between December 2009 and January 2013 with an additional year of follow-up after treatment discontinuation (January–December 2013). The peripheral refractive patterns and topographic changes are also reported individually. Results: Treatment was successful in all three subjects achieving uncorrected visual acuity of 20/20 or better monocularly. During a period of 3 years of follow-up the subjects did not experience progression in their refractive error, nor in their axial length (measured during the last 2 years of treatment and 1 year after discontinuation). Furthermore, the subjects recovered to their baseline refraction and did not progressed further over the following year after lens wear discontinuation. Conclusions: We cannot attribute a causative effect to the orthokeratology treatment alone as underlying mechanism for myopia stabilization in this 3 patients. However, the present report points to the possibility of stabilization of early adult-onset myopia progression in young adults using corneal refractive therapy treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the effect of orthokeratology for different degrees of myopia correction in the relative location of tangential (FT) and sagittal (FS) power errors across the central 70 of the visual field in the horizontal meridian. Methods: Thirty-four right eyes of 34 patients with a mean age of 25.2 ± 6.4 years were fitted with Paragon CRT (Mesa, AZ) rigid gas permeable contact lenses to treat myopia (2.15 ± 1.26D, range: 0.88 to 5.25D). Axial and peripheral refraction were measured along the central 70 of the horizontal visual field with the Grand Seiko WAM5500 open-field auto-refractor. Spherical equivalent (M), as well as tangential (FT) and sagittal power errors (FS) were obtained. Analysis was stratified in three groups according to baseline spherical equivalent: Group 1 [MBaseline = 0.88 to 1.50D; n = 11], Group 2 [MBaseline = 1.51 to 2.49D; n = 11], and Group 3 [MBaseline = 2.50 to 5.25D; n = 12]. Results: Spherical equivalent was significantly more myopic after treatment beyond the central 40 of the visual field (p50.001). FT became significantly more myopic for all groups in the nasal and temporal retina with 25 (p 0.017), 30 (p 0.007) and 35 (p 0.004) of eye rotation. Myopic change in FS was less consistent, achieving only statistical significance for all groups at 35 in the nasal and temporal retina (p 0.045). Conclusions: Orthokeratology changes significantly FT in the myopic direction beyond the central 40 of the visual field for all degrees of myopia. Changes induced by orthokeratology in relative peripheral M, FT and FS with 35 of eye rotation were significantly correlated with axial myopia at baseline. Keywords: Field

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Higher myopic refractive errors are associated with serious ocular complications that can put visual function at risk. There is respective interest in slowing and if possible stopping myopia progression before it reaches a level associated with increased risk of secondary pathology. The purpose of this report was to review our understanding of the rationale(s) and success of contact lenses (CLs) used to reduce myopia progression. Methods: A review commenced by searching the PubMed database. The inclusion criteria stipulated publications of clinical trials evaluating the efficacy of CLs in regulating myopia progression based on the primary endpoint of changes in axial length measurements and published in peerreviewed journals. Other publications from conference proceedings or patents were exceptionally considered when no peer-review articles were available. Results: The mechanisms that presently support myopia regulation with CLs are based on the change of relative peripheral defocus and changing the foveal image quality signal to potentially interfere with the accommodative system. Ten clinical trials addressing myopia regulation with CLs were reviewed, including corneal refractive therapy (orthokeratology), peripheral gradient lenses, and bifocal (dual-focus) and multifocal lenses. Conclusions: CLs were reported to be well accepted, consistent, and safe methods to address myopia regulation in children. Corneal refractive therapy (orthokeratology) is so far the method with the largest demonstrated efficacy in myopia regulation across different ethnic groups. However, factors such as patient convenience, the degree of initial myopia, and non-CL treatments may also be considered. The combination of different strategies (i.e., central defocus, peripheral defocus, spectral filters, pharmaceutical delivery, and active lens-borne illumination) in a single device will present further testable hypotheses exploring how different mechanisms can reinforce or compete with each other to improve or reduce myopia regulation with CLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alzheimer's disease (AD) is commonly associated with marked memory deficits; however, nonamnestic variants have been consistently described as well. Posterior cortical atrophy (PCA) is a progressive degenerative condition in which posterior regions of the brain are predominantly affected, therefore resulting in a pattern of distinctive and marked visuospatial symptoms, such as apraxia, alexia, and spatial neglect. Despite the growing number of studies on cognitive and neural bases of the visual variant of AD, intervention studies remain relatively sparse. Current pharmacological treatments offer modest efficacy. Also, there is a scarcity of complementary nonpharmacological interventions with only two previous studies of PCA. Here we describe a highly educated 57-year-old patient diagnosed with a visual variant of AD who participated in a cognitive intervention program (comprising reality orientation, cognitive stimulation, and cognitive training exercises). Neuropsychological assessment was performed across moments (baseline, postintervention, follow-up) and consisted mainly of verbal and visual memory. Baseline neuropsychological assessment showed deficits in perceptive and visual-constructive abilities, learning and memory, and temporal orientation. After neuropsychological rehabilitation, we observed small improvements in the patient's cognitive functioning, namely in verbal memory, attention, and psychomotor abilities. This study shows evidence of small beneficial effects of cognitive intervention in PCA and is the first report of this approach with a highly educated patient in a moderate stage of the disease. Controlled studies are needed to assess the potential efficacy of cognition-focused approaches in these patients, and, if relevant, to grant their availability as a complementary therapy to pharmacological treatment and visual aids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that color coding facilitates search and iden- tification in real-life tasks. The aim of this work was to compare reac- tion times for normal color and dichromatic observers in a visual search experiment. A unique distracter color was used to avoid abnormal color vision vulnerability to background complexity. Reaction times for nor- mal color observers and dichromats were estimated for 2◦ central vision at 48 directions around a white point in CIE L∗a∗b∗ color space for systematic examination on the mechanisms of dichromatic color percep- tion. The results show that mean search times for dichromats were twice larger compared to the normal color observers and for all directions. The difference between the copunctual confusion lines and the confusion direction measure experimentally was 5.5◦ for protanopes and 7.5◦ for deuteranopes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia e Gestão da Qualidade

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado Internacional em Sustentabilidade do Ambiente Construído

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes and validates a model-driven software engineering technique for spreadsheets. The technique that we envision builds on the embedding of spreadsheet models under a widely used spreadsheet system. This means that we enable the creation and evolution of spreadsheet models under a spreadsheet system. More precisely, we embed ClassSheets, a visual language with a syntax similar to the one offered by common spreadsheets, that was created with the aim of specifying spreadsheets. Our embedding allows models and their conforming instances to be developed under the same environment. In practice, this convenient environment enhances evolution steps at the model level while the corresponding instance is automatically co-evolved.Finally,wehave designed and conducted an empirical study with human users in order to assess our technique in production environments. The results of this study are promising and suggest that productivity gains are realizable under our model-driven spreadsheet development setting.