43 resultados para Steel quality


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents part of a study aimed at finding a suitable, yet cost-effective, surface finish for a steel structure subject to the car washing environment and corrosive chemicals. The initial, life cycle and average equivalent annual (AEAC) costs for surface finishing methods were calculated for a steel structure using the LCCC algorithm developed by American Galvanizers Association (AGA). The cost study consisted of 45 common surface finish systems including: hot-dip galvanization (HDG), metallization, acrylic, alkyd and epoxy as well as duplex coatings such as epoxy zinc and inorganic zinc (IOZ). The results show that initial, life cycle and AEAC costs for hot dip galvanization are the lowest among all the other methods, followed by coal tar epoxy painting. The annual average cost of HDG for this structure was estimated about €0.22/m2, while the other cost-effective alternatives were: IOZ, polyurea, epoxy waterborne and IOZ/epoxy duplex coating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Institutional rearing adversely affects children’s development, but the extent to which specific characteristics of the institutional context and the quality of care provided contribute to problematic development remains unclear. In this study, 72 preschoolers institutionalised for at least 6 months were evaluated by their caregiver using the Child Behavior Checklist and the Disturbances of Attachment Interview. Distal and proximate indices of institutional caregiving quality were assessed using both staff reports and direct observation. Results revealed that greater caregiver sensitivity predicted reduced indiscriminate behaviour and secure-base distortions. A closer relationship with the caregiver predicted reduced inhibited attachment behaviour. Emotional and behavioural problems proved unrelated to caregiving quality. Results are discussed in terms of (non)-shared caregiving factors that influence institutionalised children’s development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biofilm research is growing more diverse and dependent on high-throughput technologies and the large-scale production of results aggravates data substantiation. In particular, it is often the case that experimental protocols are adapted to meet the needs of a particular laboratory and no statistical validation of the modified method is provided. This paper discusses the impact of intra-laboratory adaptation and non-rigorous documentation of experimental protocols on biofilm data interchange and validation. The case study is a non-standard, but widely used, workflow for Pseudomonas aeruginosa biofilm development, considering three analysis assays: the crystal violet (CV) assay for biomass quantification, the XTT assay for respiratory activity assessment, and the colony forming units (CFU) assay for determination of cell viability. The ruggedness of the protocol was assessed by introducing small changes in the biofilm growth conditions, which simulate minor protocol adaptations and non-rigorous protocol documentation. Results show that even minor variations in the biofilm growth conditions may affect the results considerably, and that the biofilm analysis assays lack repeatability. Intra-laboratory validation of non-standard protocols is found critical to ensure data quality and enable the comparison of results within and among laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to examine the relationship among psychological, clinical and sociodemographic variables, and quality of life in women with urinary incontinence. The sample consisted of 80 women diagnosed with urinary incontinence (UI) followed in a Northern Central Hospital in Portugal. Participants answered the Incontinence Quality of Life (I-QOL); Satisfaction with Sexual Relationship Questionnaire (SSRQ); Hospital Anxiety and Depression Scales (HADS) and the Brief Cope. The results revealed that women with higher quality of life considered their symptoms of urine loss as mild or moderated compared to those with severe urine loss. The less severe urine loss was associated with greater sexual satisfaction and less use of religion and self-blame as coping strategies. In terms of coping, women who considered the loss of urine as severe expressed more feelings regarding UI. Stress urinary incontinence, high sexual satisfaction, and less use of denial, distraction, and religion as coping strategies, predicted higher quality of life. According to the results, UI has an impact on women’s sexual satisfaction and quality of life. Therefore, intervention programs should target these women, including their partners, helping them to adjust to their condition and teaching effective coping strategies in order to improve their sexual satisfaction and quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

METHODS: Refractive lens exchange was performed with implantation of an AT Lisa 839M (trifocal) or 909MP (bifocal toric) IOL, the latter if corneal astigmatism was more than 0.75 diopter (D). The postoperative visual and refractive outcomes were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. A control group of eyes in which a Tecnis ZCB00 1-piece monofocal IOL was implanted had the same examinations. RESULTS: A trifocal or bifocal toric IOL was implanted in 66 eyes. The control IOL was implanted in 18 eyes. All 3 groups obtained a significant improvement in uncorrected distance visual acuity (UDVA) (P < .001) and corrected distance visual acuity (CDVA) (P Z .001). The mean uncorrected near visual acuity (UNVA) was 0.123 logMAR with the trifocal IOL and 0.130 logMAR with the bifocal toric IOL. The residual refractive cylinder was less than 1.00 D in 86.7% of cases with the toric IOL. The mean light-distortion index was significantly higher in the multifocal IOL groups than in the monofocal group (P < .001), although no correlation was found between the light-distortion index and CDVA. CONCLUSIONS: The multifocal IOLs provided excellent UDVA and functional UNVA despite increased light-distortion indices. The light-distortion analyzer reliably quantified a subjective component of vision distinct from visual acuity; it may become a useful adjunct in the evaluation of visual quality obtained with multifocal IOLs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High levels of marine salt deposition present in coastal areas have a relevant effect on road runoff characteristics. This study assesses this effect with the purpose of identifying the relationships between monitored water quality parameters and intrinsic site variables. To achieve this objective, an extensive monitoring program was conducted on a Portuguese coastal highway. The study included 30 rainfall events, in different weather, traffic, and salt deposition conditions. The evaluations of various water quality parameters were carried out in over 200 samples. In addition, the meteorological, hydrological, and traffic parameters were continuously measured. The salt deposition rates were determined by means of a wet candle device, which is an innovative feature of the monitoring program. The relation between road runoff pollutants and independent variables associated with weather, traffic, and salt deposition conditions was assessed. Significant correlations among pollutants were observed. A high salinity concentration and its influence on the road runoff were confirmed. Furthermore, the concentrations of the most relevant pollutants seemed to be very dependent on some meteorological variables, particularly the duration of the antecedent dry period prior to each rainfall event and the average wind speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Identification of the tensile constitutive behaviour of Fibre Reinforced Concrete (FRC) represents an important aspect of the design of structural elements using this material. Although an important step has been made with the introduction of guidance for the design with regular FRC in the recently published fib Model Code 2010, a better understanding of the behaviour of this material is still necessary, mainly for that with self-compacting properties. This work presents an experimental investigation employing Steel Fibre Self-Compacting Concrete (SFRSCC) to cast thin structural elements. A new test method is proposed for assessing the post-cracking behaviour and the results obtained with the proposed test method are compared with the ones resulted from the standard three-point bending tests (3PBT). Specimens extracted from a sandwich panel consisting of SFRSCC layers are also tested. The mechanical properties of SFRSCC are correlated to the fibre distribution by analysing the results obtained with the different tests. Finally, the stress-crack width constitutive law proposed by the fib Model Code 2010 is analysed in light of the experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Biologia Molecular, Biotecnologia e Bioempreendedorismo em Plantas

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The barrier effect and the performance of an organic–inorganic hybrid (OIH) sol–gel coating are highlydependent on the coating deposition method as well as processing conditions. In this work, studies onthe influence of experimental parameters using the dip coating method were performed. Factors suchas residence time (Rt), a curing step between each dip step and the number of layers of sol–gel OIHfilms deposited on HDGS to prevent corrosion in highly alkaline environments were studied. These OIHcoatings were obtained using a functionalized siloxane, 3-isociantepropyltriethoxysilane that reactedwith a diamino-functionalized oligopolymer (Jeffamine®D-230). The barrier efficiency of OIH coatings insimulated concrete pore solutions (SCPS) was assessed in the first moments of contact, by electrochemicalimpedance spectroscopy and potentiodynamic methods. The durability and stability of the OIH coatings inSCPS was monitored during eight days by macrocell current density. The morphological characterizationof the surface was performed by scanning electronic microscopy before and after exposure to SCPS.Glow discharge optical emission spectroscopy was used to obtain quantitative composition profiles toinvestigate the thickness of the OIH coatings as a function of the number of layers deposited and theinfluence of the Rt in the coating thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic-inorganic hybrid (OIH) sol-gel coatings based on ureasilicates (U(X)) have promising properties for use as eco-friendly coatings on hot dip galvanized steel (HDGS) and may be considered potential substitutes for pre-treatment systems containing Cr(VI). These OIH coatings reduce corrosion activity during the initial stages of contact of the HDGS samples with highly alkaline environments (cementitious media) and allow the mitigation of harmful effects of an initial excessive reaction between cement pastes and the zinc layer. However, the behavior of HDGS coated with U(X) in the presence of chloride ions has never been reported. In this paper, the performance of HDGS coated with five different U(X) coatings was assessed by electrochemical measurements in chloride-contaminated simulated concrete pore solution (SCPS). U(X) sol-gel coatings were produced and deposited on HDGS by a dip coating method. The coatings performance was evaluated by electrochemical impedance spectroscopy, potentiodynamic polarization curves measurements, macrocell current density and polarization resistance in contact with chloride-contaminated SCPS. The SEM/EDS analyses of the coatings before and after the tests were also performed. The results showed that the HDGS samples coated with the OIH coatings exhibited enhanced corrosion resistance to chloride ions when compared to uncoated galvanized steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the worldwide growth of social media usage and institutionalization by organizations rise worldwide little is known about the degree of professionalization that has occurred. By comparing data between two asynchronous countries this research project offers insights into its strategic usage as well as discovering an interesting dynamic between activity and professionalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo completo publicado na revista "Journal of The Electrochemical Society" 160:10 (2013) 467-479 e disponível no RepositóriUM em: http://hdl.handle.net/1822/33855

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo completo publicado na revista "Journal of The Electrochemical Society" 161:6 (2014) C349-C362 e disponível no RepositóriUM em: http://hdl.handle.net/1822/33784

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo completo publicado na revista "Journal of The Electrochemical Society" 161:6 (2014) C349-C362 e disponível no RepositóriUM em: http://hdl.handle.net/1822/33784. Errata disponível no RepositóriUM em: http://hdl.handle.net/1822/40064. (Publisher’s note: An erratum that addressed the errors in Figure 9 was originally published on Dec. 10, 2014, however the graphs in that erratum were not correct.)