103 resultados para pre-symptomatic testing
em Indian Institute of Science - Bangalore - Índia
Resumo:
Chilli-based repellents have shown promise as deterrents against crop-raiding elephants in Africa. We experimented with ropes coated with chilli-based repellent as a cheap alternative to existing elephant cropraid deterrent methods in India. Three locations (Buxa Tiger Reserve, Wyanad Wildlife Sanctuary and Hosur Forest Division) representing varying rainfall regimes from high to low, and with histories of intense elephant-agriculture conflict, were selected for the experiments that were conducted over 2-3 months during the pre-harvest period of the kharif season in late 2006. Chilli and tobacco powder mixed with waste oil was applied to ropes strung around agricultural fields of 1.4-5.5 km perimeter and elephant approaches were monitored. Elephants breached the rope fences a few times at all three study sites. Female-led herds were far more deterred (practically 100% reduction) than were solitary males (c. 50%) by the chilli-tobacco rope. Efficacy of this method as a deterrent was significantly better in the low-rainfall regime relative to medium and high-rainfall regimes. The initial promising results present a case for more rigorous experimentation; these would help determine if the elephants avoiding the rope are responding physiologically to the chilli-tobacco smell or merely reacting cautiously to a novel substance in their environment.
Resumo:
Clay liners have been widely used to contain toxic and hazardous waste materials. Clays absorb contaminant cations due to their exchange capacity. To improve the performance of the clay liner, fly ash, a waste material arising from the combustion of coal has been studied as a pre-filter material. In particular, the retention of lead by two different fly ashes was studied. The influence of pH on retention as well as leaching characteristics are also examined. The results obtained from the retention experiments by the permeameter method indicate that fly ash retains the lead ions through precipitation in the pores as well as onto the surface when the ambient pH value is more than 5.5, and through adsorption when the pH value is less than 5.5. It has been observed that fly ash did not release the retained lead ions when the pH value is between 3.5 and 10.0. Hence, the retention of lead ions by fly ash is likely to be permanent since the pH of most of the municipal landfill leachates are within 3.7 to 8.8. However, for highly acidic or alkaline leachates, the retained ions can get released.
Resumo:
Aerosol black carbon (BC) mass concentrations ([BC]), measured continuously during a multi-platform field experiment, Integrated Campaign for Aerosols gases and Radiation Budget (ICARB, March-May 2006), from a network of eight observatories spread over geographically distinct environments of India, (which included five mainland stations, one highland station, and two island stations (one each ill Arabian Sea and Bay of Bengal)) are examined for their spatio-temporal characteristics. During the period of study, [BC] showed large variations across the country, with values ranging from 27 mu g m(3) over industrial/urban locations to as low as 0.065 mu g m(-3) over the Arabian Sea. For all mainland stations, [BC] remained high compared to highland as well as island stations. Among the island stations, Port Blair (PBR) had higher concentration of BC, compared to Minicoy (MCY), implying more absorbing nature of Bay of Bengal aerosols than Arabian Sea. The highland station Nainital (NTL), in the central Himalayas, showed low values of [BC], comparable or even lower than that of the island station PBR, indicating the prevalence of cleaner environment over there. An examination of the changes in the mean temporal features, as the season advances from winter (December-February) to pre-monsoon (March-May), revealed that: (a) Diurnal variations were pronounced over all the mainland stations, with all afternoon low and a nighttime high: (b) At the islands, the diurnal variations, though resembled those over the mainlands, were less pronounced; and (c) In contrast to this, highland station showed an opposite pattern with an afternoon high and a late night or early morning low. The diurnal variations at all stations are mainly caused by the dynamics of local Atmospheric Boundary Layer (ABL), At the entire mainland as well as island stations (except HYD and DEL), [BC] showed a decreasing trend from January to May, This is attributed to the increased convective mixing and to the resulting enhanced vertical dispersal of species in the ABL. In addition, large short-period modulations were observed at DEL and HYD, which appeared to be episodic, An examination of this in the light of the MODIS-derived fire count data over India along with the back-trajectory analysis revealed that advection of BC from extensive forest fires and biomass-burning regions upwind were largely responsible for this episodic enhancement in BC at HYD and DEL.
Resumo:
A geometrical structure called the implied minterm structure (IMS) has been developed from the properties of minterms of a threshold function. The IMS is useful for the manual testing of linear separability of switching functions of up to six variables. This testing is done just by inspection of the plot of the function on the IMS.
Resumo:
The two-dimensional,q-state (q>4) Potts model is used as a testing ground for approximate theories of first-order phase transitions. In particular, the predictions of a theory analogous to the Ramakrishnan-Yussouff theory of freezing are compared with those of ordinary mean-field (Curie-Wiess) theory. It is found that the Curie-Weiss theory is a better approximation than the Ramakrishnan-Yussouff theory, even though the former neglects all fluctuations. It is shown that the Ramakrishnan-Yussouff theory overestimates the effects of fluctuations in this system. The reasons behind the failure of the Ramakrishnan-Yussouff approximation and the suitability of using the two-dimensional Potts model as a testing ground for these theories are discussed.
Resumo:
Length scale-down (LS) model tests have been traditionally employed for laboratory studies on aeolian vibration of transmission line conductors. The span adopted is normally 30 m and is recommended by the relevant Indian, as well as other, standards. The traditionally adopted length of the LS model is reexamined herein to establish the rationale behind the choice. Based on the theoretical studies discussed, certain guidelines for the choice of model span of conductor are emphasized. In addition, the adequacy of the LS span as a tool for predicting the performance of the full span is reestablished.
Resumo:
The paper presents, in three parts, a new approach to improve the detection and tracking performance of a track-while-scan radar. Part 1 presents a review of the current status of the subject. Part 2 details the new approach. It shows how a priori information provided by the tracker can be used to improve detection. It also presents a new multitarget tracking algorithm. In the present Part, analytical derivations are presented for assessing, a priori, the performance of the TWS radar system. True track initiation, false track initiation, true track continuation and false track deletion characteristics have been studied. It indicates how the various thresholds can be chosen by the designer to optimise performance. Simulation results are also presented.
Studies on serum progesterone levels in Zebu × Holstein heifers during pre- and peripubertal periods
Resumo:
The peripheral serum progesterone levels of six normal Zebu × Holstein heifers (75% Holstein inheritance) during the prepubertal period (−150 days) were low (0.23 ± 0.06 ng/ml). They reached maximal values (0.73 ± 0.06 ng/ml) by −45 days (P<0.05 for progesterone values on −90th vs. −45th days) and thereafter decreased to the base level at the time of puberty. The mean (± SEM) age and body weight at puberty of these six heifers were 720 ± 20.70 days and 260.67 ± 8.82 kg, respectively. The serum progesterone levels remained low (0.38 ± 0.17 ng/ml) during early oestrus (up to 28 h) and gradually increased to 2.3 ± 0.84 ng/ml by the 15th day of the cycle.
Resumo:
This paper presents a general hardware scheme for testing protective relays using microprocessor based systems. The microprocessor simulates the relaying signals for test purpose and monitors the relay performance. Based on the proposed hardware, a teat procedure for directional overcurrent relays is presented in detail. Typical test results of various routine tests conducted on a commercial single phase directional over-current relay clearly demonstrate the efficacy of the proposed technique for conducting tests on commercial relays.
Resumo:
A waverider is a lifting body configuration whose upper surface is parallel to the free stream, and the lower surface aerodynamically so designed, that the resulting shock at the design Mach number, is always attached with the leading edge of the vehicle. This prevents spillage from high pressure (lower) surface to the low pressure (upper) surface.In the present study a conical waverider has been designed, fabricated and tested at Mach 6 in the IISc hypersonic shock tunnel HST2. The measurements show that the waverider has a lift to drag ratio of 4.28 at the designed Mach number. Exhaustive FEM and CFD studies are also carried out to complement the force measurements in the tunnel.
Resumo:
Epidemiology of symptomatic rotaviruses from Bangalore and Mysore in Southern India was investigated. While serotype G3 predominated throughout the 7-year study period from 1988 to 1994 in Bangalore, serotype G1 was more predominant than serotype G3 in Mysore during 1993 and 1994. Serotype G2 strains were either not detected or infrequently observed in both the cities. However, several strains with subgroup I and lsquoshortrsquo RNA pattern that exhibited high reactivity with typing MAbs specific for serotype 2 as well as other serotypes were detected throughout the period. Among the nonserotypeable strains from both cities, several exhibited dual subgroup (SGI+II) or subgroup I specificity and lsquolongrsquo RNA pattern indicating their probable animal origin. Notably, a gradual, yet highly significant reduction in rotavirus gastroenteritis, from 45.3% in 1988 to 1.8% during 1994, was observed in Bangalore in stark contrast to the consistently high (about 34%) incidence of asymptomatic infections among neonates by I321-like G10P11 type strains during the same period. Moreover, I321-like asymptomatic strains were not detected in children with diarrhea.
Resumo:
The Mueller-Stokes formalism that governs conventional polarization optics is formulated for plane waves, and thus the only qualification one could require of a 4 x 4 real matrix M in order that it qualify to be the Mueller matrix of some physical system would be that M map Omega((pol)), the positive solid light cone of Stokes vectors, into itself. In view of growing current interest in the characterization of partially coherent partially polarized electromagnetic beams, there is a need to extend this formalism to such beams wherein the polarization and spatial dependence are generically inseparably intertwined. This inseparability brings in additional constraints that a pre-Mueller matrix M mapping Omega((pol)) into itself needs to meet in order to be an acceptable physical Mueller matrix. These additional constraints are motivated and fully characterized. (C) 2010 Optical Society of America
Resumo:
The room temperature (RT) tensile behaviour of a free-standing high activity Pt-aluminide bond coat has been evaluated by microtensile testing technique. The coating had a typical three-layer microstructure. The stress-strain plot for the free-standing coating was linear, indicating the coating to be brittle at RT. Different fracture features were observed across the coating layers, namely quasi-cleavage in the outer layer and inner interdiffusion zone, and cleavage in the intermediate layer. By employing interrupted tensile test and observing the cross-sectional microstructure of the tested specimens, it was determined that failure of the microtensile samples occurred by the initiation of a single crack in the intermediate layer of the coating and its subsequent inside-out propagation. Such a mechanism of failure has been explained in terms of the fracture features observed across the sample thickness. This mechanism of failure is consistent with fracture toughness values of the individual coating layers. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Magnetorheological dampers are intrinsically nonlinear devices, which make the modeling and design of a suitable control algorithm an interesting and challenging task. To evaluate the potential of magnetorheological (MR) dampers in control applications and to take full advantages of its unique features, a mathematical model to accurately reproduce its dynamic behavior has to be developed and then a proper control strategy has to be taken that is implementable and can fully utilize their capabilities as a semi-active control device. The present paper focuses on both the aspects. First, the paper reports the testing of a magnetorheological damper with an universal testing machine, for a set of frequency, amplitude, and current. A modified Bouc-Wen model considering the amplitude and input current dependence of the damper parameters has been proposed. It has been shown that the damper response can be satisfactorily predicted with this model. Second, a backstepping based nonlinear current monitoring of magnetorheological dampers for semi-active control of structures under earthquakes has been developed. It provides a stable nonlinear magnetorheological damper current monitoring directly based on system feedback such that current change in magnetorheological damper is gradual. Unlike other MR damper control techniques available in literature, the main advantage of the proposed technique lies in its current input prediction directly based on system feedback and smooth update of input current. Furthermore, while developing the proposed semi-active algorithm, the dynamics of the supplied and commanded current to the damper has been considered. The efficiency of the proposed technique has been shown taking a base isolated three story building under a set of seismic excitation. Comparison with widely used clipped-optimal strategy has also been shown.
Resumo:
Enhanced Scan design can significantly improve the fault coverage for two pattern delay tests at the cost of exorbitantly high area overhead. The redundant flip-flops introduced in the scan chains have traditionally only been used to launch the two-pattern delay test inputs, not to capture tests results. This paper presents a new, much lower cost partial Enhanced Scan methodology with both improved controllability and observability. Facilitating observation of some hard to observe internal nodes by capturing their response in the already available and underutilized redundant flip-flops improves delay fault coverage with minimal or almost negligible cost. Experimental results on ISCAS'89 benchmark circuits show significant improvement in TDF fault coverage for this new partial enhance scan methodology.