88 resultados para Logic forms
em Indian Institute of Science - Bangalore - Índia
Resumo:
Canonical forms for m-valued functions referred to as m-Reed-Muller canonical (m-RMC) forms that are a generalization of RMC forms of two-valued functions are proposed. m-RMC forms are based on the operations ?m (addition mod m) and .m (multiplication mod m) and do not, as in the cases of the generalizations proposed in the literature, require an m-valued function for m not a power of a prime, to be expressed by a canonical form for M-valued functions, where M > m is a power of a prime. Methods of obtaining the m-RMC forms from the truth vector or the sum of products representation of an m-valued function are discussed. Using a generalization of the Boolean difference to m-valued logic, series expansions for m-valued functions are derived.
Resumo:
The chain length of the surfactant and the solvent composition are two of the factors that determine whether the lamellar or the hexagonal form of mesoporous SiO2 (or ZrO2) is formed by the neutral amine route; a lamellar-hexagonal transformation occurs on removal of the amine from the former.
Resumo:
Recent research in modelling uncertainty in water resource systems has highlighted the use of fuzzy logic-based approaches. A number of research contributions exist in the literature that deal with uncertainty in water resource systems including fuzziness, subjectivity, imprecision and lack of adequate data. This chapter presents a broad overview of the fuzzy logic-based approaches adopted in addressing uncertainty in water resource systems modelling. Applications of fuzzy rule-based systems and fuzzy optimisation are then discussed. Perspectives on the scope for further research are presented.
Resumo:
Dimeric and monomeric forms of the enzyme triosephosphate isomerase (TIM) from Plasmodium falciparum (Pf) have been detected under conditions of nanoflow by electrospray mass spectrometry. The dimer (M = 55 663 Da) exhibits a narrow charge state distribution with intense peaks limited to values of 18(+) to 21(+), maximal intensity being observed for charge states 19(+) and 20(+). A monomeric species with a charge state distribution ranging from 11(+) to 16(+) is also observed, which may be assigned to folded dissociated subunits. Complete dimer dissociation results under normal electrospray condition. The effects of solution pH and source temperature have been investigated. The observation of four distinct charge state distributions which may be assigned to a dimer, folded monomer, partially folded monomer and unfolded monomer is reported. Circular dichromism and fluorescence studies of Pf TIM at low pH support the retention of substantial secondary and tertiary structures. Satellite peaks in mass spectra corresponding to hydrated species are also observed and isotope shift upon deuteration is demonstrated. The analysis of all available independent crystal structures of Pf TIM and TIMs from other organisms permits identification of structurally conserved water molecules. Hydration observed in the dimer and folded monomeric forms in the gas phase may correspond to these conserved sites.
Resumo:
Conformational preferences of thiocarbonohydrazide (H2NNHCSNHNH2) in its basic and N,N′-diprotonated forms are examined by calculating the barrier to internal rotation around the C---N bonds, using the theoretical LCAO—MO (ab initio and semiempirical CNDO and EHT) methods. The calculated and experimental results are compared with each other and also with values for N,N′-dimethylthiourea which is isoelectronic with thiocarbonohydrazide. The suitability of these methods for studying rotational isomerism seems suspect when lone pair interactions are present.
Resumo:
Based on trial interchanges, this paper develops three algorithms for the solution of the placement problem of logic modules in a circuit. A significant decrease in the computation time of such placement algorithms can be achieved by restricting the trial interchanges to only a subset of all the modules in a circuit. The three algorithms are simulated on a DEC 1090 system in Pascal and the performance of these algorithms in terms of total wirelength and computation time is compared with the results obtained by Steinberg, for the 34-module backboard wiring problem. Performance analysis of the first two algorithms reveals that algorithms based on pairwise trial interchanges (2 interchanges) achieve a desired placement faster than the algorithms based on trial N interchanges. The first two algorithms do not perform better than Steinberg's algorithm1, whereas the third algorithm based on trial pairwise interchange among unconnected pairs of modules (UPM) and connected pairs of modules (CPM) performs better than Steinberg's algorithm, both in terms of total wirelength (TWL) and computation time.
Resumo:
In this paper, the validity of'single fault assumption in deriving diagnostic test sets is examined with respect to crosspoint faults in programmable logic arrays (PLA's). The control input procedure developed here can be used to convert PLA's having undetectable crosspoint faults to crosspoint-irredundant PLA's for testing purposes. All crosspoints will be testable in crosspoint-irredundant PLA's. The control inputs are used as extra variables during testing. They are maintained at logic I during normal operation. A useful heuristic for obtaining a near-minimal number of control inputs is suggested. Expressions for calculating bounds on the number of control inputs have also been obtained.
Resumo:
An on-line algorithm is developed for the location of single cross point faults in a PLA (FPLA). The main feature of the algorithm is the determination of a fault set corresponding to the response obtained for a failed test. For the apparently small number of faults in this set, all other tests are generated and a fault table is formed. Subsequently, an adaptive procedure is used to diagnose the fault. Functional equivalence test is carried out to determine the actual fault class if the adaptive testing results in a set of faults with identical tests. The large amount of computation time and storage required in the determination, a priori, of all the fault equivalence classes or in the construction of a fault dictionary are not needed here. A brief study of functional equivalence among the cross point faults is also made.
Resumo:
he Dirac generator formalism for relativistic Hamiltonian dynamics is reviewed along with its extension to constraint formalism. In these theories evolution is with respect to a dynamically defined parameter, and thus time evolution involves an eleventh generator. These formulations evade the No-Interaction Theorem. But the incorporation of separability reopens the question, and together with the World Line Condition leads to a second no-interaction theorem for systems of three or more particles. Proofs are omitted, but the results of recent research in this area is highlighted.
Resumo:
A fuzzy logic based centralized control algorithm for irrigation canals is presented. Purpose of the algorithm is to control downstream discharge and water level of pools in the canal, by adjusting discharge release from the upstream end and gates settings. The algorithm is based on the dynamic wave model (Saint-Venant equations) inversion in space, wherein the momentum equation is replaced by a fuzzy rule based model, while retaining the continuity equation in its complete form. The fuzzy rule based model is developed on fuzzification of a new mathematical model for wave velocity, the derivational details of which are given. The advantages of the fuzzy control algorithm, over other conventional control algorithms, are described. It is transparent and intuitive, and no linearizations of the governing equations are involved. Timing of the algorithm and method of computation are explained. It is shown that the tuning is easy and the computations are straightforward. The algorithm provides stable, realistic and robust outputs. The disadvantage of the algorithm is reduced precision in its outputs due to the approximation inherent in the fuzzy logic. Feed back control logic is adopted to eliminate error caused by the system disturbances as well as error caused by the reduced precision in the outputs. The algorithm is tested by applying it to water level control problem in a fictitious canal with a single pool and also in a real canal with a series of pools. It is found that results obtained from the algorithm are comparable to those obtained from conventional control algorithms.
Resumo:
An on-line algorithm is developed for the location of single cross point faults in a PLA (FPLA). The main feature of the valgorithm is the determination of a fault set corresponding to the response obtained for a failed test. For the apparently small number of faults in this set, all other tests are generated and a fault table is formed. Subsequently, an adaptive procedure is used to diagnose the fault. Functional equivalence test is carried out to determine the actual fault class if the adaptive testing results in a set of faults with identical tests. The large amount of computation time and storage required in the determination, a priori, of all the fault equivalence classes or in the construction of a fault dictionary are not needed here. A brief study of functional equivalence among the cross point faults is also made.
Resumo:
A fuzzy logic system (FLS) with a new sliding window defuzzifier is proposed for structural damage detection using modal curvatures. Changes in the modal curvatures due to damage are fuzzified using Gaussian fuzzy sets and mapped to damage location and size using the FLS. The first four modal vectors obtained from finite element simulations of a cantilever beam are used for identifying the location and size of damage. Parametric studies show that modal curvatures can be used to accurately locate the damage; however, quantifying the size of damage is difficult. Tests with noisy simulated data show that the method detects damage very accurately at different noise levels and when some modal data are missing.
Resumo:
This paper describes a switching theoretic algorithm for the folding of programmable logic arrays (PLA). The algorithm is valid for both column and row folding, although it has been presented considering only the simple column folding. The pairwise compatibility relations among all the pairs of the columns of the PLA are mapped into a square matrix, called the compatibility matrix of the PLA. A foldable compatibility matrix (FCM), a new concept introduced by the author, is then derived from the compatibility matrix. A new theorem called the folding theorem is then proved. The theorem states that the existence of an m by 2m FCM is both necessary and sufficient to fold 2m columns of the n column PLA (2m ≤ n). Once an FCM is obtained, the ordered pairs of foldable columns and the re-ordering of the rows are readily determined.
Resumo:
The prefered tautomer(s) of hydroxycyclotriphosphazatrienes and prototropic exchange in solution have been established by 31P n.m.r. spectroscopy, thus confirming predictions deduced from basicity calculations; the X-ray structure of N3P3Ph2(OMe)3OH shows that it exists as the hydrogen-bonded dimer of the oxophosphazadiene tautomer in which a proton is adjacent to the PPh2 group.
Resumo:
Uncertainties associated with the structural model and measured vibration data may lead to unreliable damage detection. In this paper, we show that geometric and measurement uncertainty cause considerable problem in damage assessment which can be alleviated by using a fuzzy logic-based approach for damage detection. Curvature damage factor (CDF) of a tapered cantilever beam are used as damage indicators. Monte Carlo simulation (MCS) is used to study the changes in the damage indicator due to uncertainty in the geometric properties of the beam. Variation in these CDF measures due to randomness in structural parameter, further contaminated with measurement noise, are used for developing and testing a fuzzy logic system (FLS). Results show that the method correctly identifies both single and multiple damages in the structure. For example, the FLS detects damage with an average accuracy of about 95 percent in a beam having geometric uncertainty of 1 percent COV and measurement noise of 10 percent in single damage scenario. For multiple damage case, the FLS identifies damages in the beam with an average accuracy of about 94 percent in the presence of above mentioned uncertainties. The paper brings together the disparate areas of probabilistic analysis and fuzzy logic to address uncertainty in structural damage detection.