91 resultados para Web testing
Resumo:
Magnetorheological dampers are intrinsically nonlinear devices, which make the modeling and design of a suitable control algorithm an interesting and challenging task. To evaluate the potential of magnetorheological (MR) dampers in control applications and to take full advantages of its unique features, a mathematical model to accurately reproduce its dynamic behavior has to be developed and then a proper control strategy has to be taken that is implementable and can fully utilize their capabilities as a semi-active control device. The present paper focuses on both the aspects. First, the paper reports the testing of a magnetorheological damper with an universal testing machine, for a set of frequency, amplitude, and current. A modified Bouc-Wen model considering the amplitude and input current dependence of the damper parameters has been proposed. It has been shown that the damper response can be satisfactorily predicted with this model. Second, a backstepping based nonlinear current monitoring of magnetorheological dampers for semi-active control of structures under earthquakes has been developed. It provides a stable nonlinear magnetorheological damper current monitoring directly based on system feedback such that current change in magnetorheological damper is gradual. Unlike other MR damper control techniques available in literature, the main advantage of the proposed technique lies in its current input prediction directly based on system feedback and smooth update of input current. Furthermore, while developing the proposed semi-active algorithm, the dynamics of the supplied and commanded current to the damper has been considered. The efficiency of the proposed technique has been shown taking a base isolated three story building under a set of seismic excitation. Comparison with widely used clipped-optimal strategy has also been shown.
Resumo:
Enhanced Scan design can significantly improve the fault coverage for two pattern delay tests at the cost of exorbitantly high area overhead. The redundant flip-flops introduced in the scan chains have traditionally only been used to launch the two-pattern delay test inputs, not to capture tests results. This paper presents a new, much lower cost partial Enhanced Scan methodology with both improved controllability and observability. Facilitating observation of some hard to observe internal nodes by capturing their response in the already available and underutilized redundant flip-flops improves delay fault coverage with minimal or almost negligible cost. Experimental results on ISCAS'89 benchmark circuits show significant improvement in TDF fault coverage for this new partial enhance scan methodology.
Resumo:
A method of testing for parametric faults of analog circuits based on a polynomial representation of fault-free function of the circuit is presented. The response of the circuit under test (CUT) is estimated as a polynomial in the applied input voltage at relevant frequencies in addition to DC. Classification or Cur is based on a comparison of the estimated polynomial coefficients with those of the fault free circuit. This testing method requires no design for test hardware as might be added to the circuit fly some other methods. The proposed method is illustrated for a benchmark elliptic filter. It is shown to uncover several parametric faults causing deviations as small as 5% from the nominal values.
Resumo:
Encoding protein 3D structures into 1D string using short structural prototypes or structural alphabets opens a new front for structure comparison and analysis. Using the well-documented 16 motifs of Protein Blocks (PBs) as structural alphabet, we have developed a methodology to compare protein structures that are encoded as sequences of PBs by aligning them using dynamic programming which uses a substitution matrix for PBs. This methodology is implemented in the applications available in Protein Block Expert (PBE) server. PBE addresses common issues in the field of protein structure analysis such as comparison of proteins structures and identification of protein structures in structural databanks that resemble a given structure. PBE-T provides facility to transform any PDB file into sequences of PBs. PBE-ALIGNc performs comparison of two protein structures based on the alignment of their corresponding PB sequences. PBE-ALIGNm is a facility for mining SCOP database for similar structures based on the alignment of PBs. Besides, PBE provides an interface to a database (PBE-SAdb) of preprocessed PB sequences from SCOP culled at 95% and of all-against-all pairwise PB alignments at family and superfamily levels. PBE server is freely available at http://bioinformatics.univ-reunion.fr/ PBE/.
Resumo:
Owing to high evolutionary divergence, it is not always possible to identify distantly related protein domains by sequence search techniques. Intermediate sequences possess sequence features of more than one protein and facilitate detection of remotely related proteins. We have demonstrated recently the employment of Cascade PSI-BLAST where we perform PSI-BLAST for many 'generations', initiating searches from new homologues as well. Such a rigorous propagation through generations of PSI-BLAST employs effectively the role of intermediates in detecting distant similarities between proteins. This approach has been tested on a large number of folds and its performance in detecting superfamily level relationships is similar to 35% better than simple PSI-BLAST searches. We present a web server for this search method that permits users to perform Cascade PSI-BLAST searches against the Pfam, SCOP and SwissProt databases. The URL for this server is http://crick.mbu.iisc.ernet.in/similar to CASCADE/CascadeBlast.html.
Resumo:
During the course of genome studies in a rural community in the South Indian state of Karnataka, DNA-based investigations and counselling for familial adenomatous polyposis (FAP) were requested via the community physician. The proposita died in 1940 and FAP had been clinically diagnosed in 2 of her 5 children, both deceased. DNA samples from 2 affected individuals in the third generation were screened for mutations in the APC gene, and a frame-shift mutation was identified in exon 15 with a common deletion at codon 1061. Predictive testing for the mutation was then organized on a voluntary basis. There were 11 positive tests, including confirmatory positives on 2 persons diagnosed by colonoscopy, and to date surgery has been successfully undertaken on 3 previously undiagnosed adults. The ongoing success of the study indicates that, with appropriate access to the facilities offered by collaborating centres, predictive testing is feasible for diseases such as FAP and could be of significant benefit to communities in economically less developed countries.
Resumo:
A relationship between 2-monotonicity and 2-asummability has been established and thereby a fast method for testing 2-asummability of switching functions derived. The approach is based on the fact that only a particular type of 2-sums need be examined for 2-asummability testing of 2-monotonic switching functions. These 2-sums are those which contain more than five 1's. 2-asummability testing for these 2-sums can be easily done by using the authors' technique.
Resumo:
The effect of injecting agonistic and antagonistic analogues of gonadotropin releasing hormone analogues on serum testosterone levels was checked in adult and immature male bonnet monkeys. Of the agonistic analogues Buserelin, Ovurelin and D-Phe6 Gln8 GnRH were found to be most potent in increasing serum testosterone levels in the adult male bonnet monkeys. While 27-month-old monkeys responded well to des Gly10 GnRH, only marginal response was observed in the case of 15-month-old monkeys. Studies carried out with Ovurelin indicated that it was not effective in causing desensitization in adult monkeys. The antagonistic analogue was effective in blocking nocturnal surge of serum testosterone. Based on these studies it is suggested the adult male bonnet monkeys can be effectively used for testing the activity of GnRH analogues.
Resumo:
Chilli-based repellents have shown promise as deterrents against crop-raiding elephants in Africa. We experimented with ropes coated with chilli-based repellent as a cheap alternative to existing elephant cropraid deterrent methods in India. Three locations (Buxa Tiger Reserve, Wyanad Wildlife Sanctuary and Hosur Forest Division) representing varying rainfall regimes from high to low, and with histories of intense elephant-agriculture conflict, were selected for the experiments that were conducted over 2-3 months during the pre-harvest period of the kharif season in late 2006. Chilli and tobacco powder mixed with waste oil was applied to ropes strung around agricultural fields of 1.4-5.5 km perimeter and elephant approaches were monitored. Elephants breached the rope fences a few times at all three study sites. Female-led herds were far more deterred (practically 100% reduction) than were solitary males (c. 50%) by the chilli-tobacco rope. Efficacy of this method as a deterrent was significantly better in the low-rainfall regime relative to medium and high-rainfall regimes. The initial promising results present a case for more rigorous experimentation; these would help determine if the elephants avoiding the rope are responding physiologically to the chilli-tobacco smell or merely reacting cautiously to a novel substance in their environment.
Resumo:
A finite element method (FEM)-based study has been carried out for the design of flat microtensile samples to evaluate tensile properties of Pt-aluminide (PtAl) bond coats. The critical dimensions of the sample have been determined using a two-dimensional elastic stress analysis. In the present testing scheme, the ratio of the dimensions of the holding length to the fillet radius of the sample was found important to achieve failure within the gage length. The effect of gage length and grip head length also has been examined. The simulation predictions have been experimentally verified by conducting microtensile test of an actual PtAl bond coat at room temperature. The sample design and testing scheme suggested in this study have also been found suitable for evaluation of tensile properties at high temperature. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Optimum design of dynamic fracture test rigs demands a thorough appreciation of beam vibration under impact. Analyses invariably presume rigid anvils, and neglect overhang effects. The beam response predicted analytically and numerically in this paper highlights the significant role of anvil rigidity and beam overhangs on the impact dynamics of three point bend (3PB) specimens.
Resumo:
Background—Mutations of the APC gene cause familial adenomatous polyposis (FAP), a hereditary colorectal cancer predisposition syndrome.Aims—To conduct a cost comparison analysis of predictive genetic testing versus conventional clinical screening for individuals at risk of inheriting FAP, using the perspective of a third party payer. Methods—All direct health care costs for both screening strategies were measured according to time and motion, and the expected costs evaluated using a decision analysis model.Results—The baseline analysis predicted that screening a prototype FAP family would cost $4975/£3109 by molecular testingand $8031/£5019 by clinical screening strategy, when family members were monitored with the same frequency of clinical surveillance (every two to three years). Sensitivity analyses revealed that the genetic testing approach is cost saving for key variables including the kindred size, the age of screening onset, and the cost of mutation identification in a proband. However, if the APC mutation carriers were monitored at an increased (annual) frequency, the cost of the genetic screening strategy increased to $7483/ £4677 and was especially sensitive to variability in age of onset of screening, family size, and cost of genetic testing of at risk relatives. Conclusions—In FAP kindreds, a predictive genetic testing strategy costs less than conventional clinical screening, provided that the frequency of surveillance is identical using either strategy. An additional significant benefit is the elimination of unnecessary colonic examinations for those family members found to be noncarriers.
Resumo:
The determination of consolidation characteristics forms an important aspect in the design of foundations and other earth-retaining structures. The conventional consolidation test as originally proposed by Teaaghi takes considerable time (more than 15 days in highly compressible soils with low coefficient of consolidation) and effort. Any effort to reduce the duration of testing will be desirable from several considerations. In this paper, an attempt has been made to propose a rapid method of consolidation testing. In the proposed method, the next load increment is applied as soon as the necessary time required to identify the percent consolidation is reached and to evaluate the coefficient of consolidation by one of the popular curve-fitting procedures. The rectangular hyperbola method has been used to identify the percent consolidation reached after any load increment, and to determine the coefficient of consolidation, before making the next load increment. The time required to complete the test using the rapid consolidation method could be as low as 4-5 h compared with 1 or 2 weeks in the case of the conventional consolidation test.