6 resultados para Time-Optimal Control

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis integrates real-time feedback control into an optical tweezers instrument. The goal is to reduce the variance in the trapped bead s position, -effectively increasing the trap stiffness of the optical tweezers. Trap steering is done with acousto-optic deflectors and control algorithms are implemented with a field-programmable gate array card. When position clamp feedback control is on, the effective trap stiffness increases 12.1-times compared to the stiffness without control. This allows improved spatial control over trapped particles without increasing the trapping laser power.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Molecular machinery on the micro-scale, believed to be the fundamental building blocks of life, involve forces of 1-100 pN and movements of nanometers to micrometers. Micromechanical single-molecule experiments seek to understand the physics of nucleic acids, molecular motors, and other biological systems through direct measurement of forces and displacements. Optical tweezers are a popular choice among several complementary techniques for sensitive force-spectroscopy in the field of single molecule biology. The main objective of this thesis was to design and construct an optical tweezers instrument capable of investigating the physics of molecular motors and mechanisms of protein/nucleic-acid interactions on the single-molecule level. A double-trap optical tweezers instrument incorporating acousto-optic trap-steering, two independent detection channels, and a real-time digital controller was built. A numerical simulation and a theoretical study was performed to assess the signal-to-noise ratio in a constant-force molecular motor stepping experiment. Real-time feedback control of optical tweezers was explored in three studies. Position-clamping was implemented and compared to theoretical models using both proportional and predictive control. A force-clamp was implemented and tested with a DNA-tether in presence of the enzyme lambda exonuclease. The results of the study indicate that the presented models describing signal-to-noise ratio in constant-force experiments and feedback control experiments in optical tweezers agree well with experimental data. The effective trap stiffness can be increased by an order of magnitude using the presented position-clamping method. The force-clamp can be used for constant-force experiments, and the results from a proof-of-principle experiment, in which the enzyme lambda exonuclease converts double-stranded DNA to single-stranded DNA, agree with previous research. The main objective of the thesis was thus achieved. The developed instrument and presented results on feedback control serve as a stepping stone for future contributions to the growing field of single molecule biology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Single molecule force clamp experiments are widely used to investigate how enzymes, molecular motors, and other molecular mechanisms work. We developed a dual-trap optical tweezers instrument with real-time (200 kHz update rate) force clamp control that can exert 0–100 pN forces on trapped beads. A model for force clamp experiments in the dumbbell-geometry is presented. We observe good agreement between predicted and observed power spectra of bead position and force fluctuations. The model can be used to predict and optimize the dynamics of real-time force clamp optical tweezers instruments. The results from a proof-of-principle experiment in which lambda exonuclease converts a double-stranded DNA tether, held at constant tension, into its single-stranded form, show that the developed instrument is suitable for experiments in single molecule biology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Soft tissue sarcomas are malignant tumours of mesenchymal origin. Because of infiltrative growth pattern, simple enucleation of the tumour causes a high rate of local recurrence. Instead, these tumours should be resected with a rim of normal tissue around the tumour. Data on the adequate margin width are scarce. At Helsinki University Central Hospital (HUCH) a multidisciplinary treatment group started in 1987. Surgical resection with a wide margin (2.5 cm) is the primary aim. In case of narrower margin radiation therapy is necessary. The role of adjuvant chemotherapy remains unclear. Our aims were to study local control by the surgical margin and to develop a new prognostic tool to aid decision-making on which patients should receive adjuvant chemotherapy. Patients with soft tissue sarcoma of the extremity or the trunk wall referred to HUCH during 1987-2002 form material in Studies I and II. External validation material comes from the Lund university sarcoma registry. The smallest surgical margin of at least 2.5 centimetres yielded local control of 89 per cent at five years. Amputation rate was 9 per cent. The proposed prognostic model with necrosis, vascular invasion, size on a continuous scale, depth, location and grade worked well both in Helsinki material and in the validation material, and it also showed good calibration. Based on the present study, we recommend the smallest surgical margin of 2-3 centimetres in soft tissue sarcoma irrespective of grade. Improvement in local control was present but modest in margins wider than 1 centimetre. In cases where gaining a wider margin would lead to a considerable loss of function, smaller margin is to be considered combined to radiation therapy. Patients treated with inadequate margins should be offered radiation therapy irrespective of tumour grade. Our new prognostic model to estimate 10-year survival probability in patients with soft tissue sarcoma of the extremities or trunk wall showed good dicscrimination and calibration. For time being the prognostic model is available for scientific use and further validations. In the future, the model may aid in clinical decision-making. For operable osteosarcoma, neoadjuvant multidrug chemotherapy followed by delayed surgery and multidrug adjuvant chemotherapy is the treatment of choice. Overall survival rates at five years are approximately 75 per cent in modern trials with classical osteosarcoma. All patients diagnosed and reported to the Finnish Cancer Registry with osteosarcoma in Finland during 1971-2005 form the material in Studies III and IV. Limb-salvage rate increased from 23 per cent to 78 per cent during 1971-2005. The 10-year sarcoma-specific survival for the whole study population improved from 32 per cent to 62 per cent. It was 75 per cent for patients with a local high-grade osteosarcoma of the extremity diagnosed during 1991-2005. This study outlines the improved prognosis of osteosarcoma patients in Finland with modern chemotherapy. The 10-year survival rates are good also in an international scale. Nonetheless, their limb-salvage rate remains inferior to those seen for highly selected patient series. Overall, the centralisation of osteosarcoma treatment would most likely improve both survival and limb-salvage rates even further.